Thermo Scientific™

MAbPac™ SCX-10 RS Monoclonal Antibody Analysis Column, 5μm

產品號碼: 082515
Thermo Scientific™

MAbPac™ SCX-10 RS Monoclonal Antibody Analysis Column, 5μm

產品號碼: 082515

For high-resolution, high efficiency analysis of monoclonal antibodies (mAbs) and associated variants, use Thermo Scientific™ MAbPac™ SCX-10 RS Monoclonal Antibody Analysis Columns, 5μm. The unique nonporous pellicular resin provides the resolving power to separate mAb variants that differ by as little as one charged residue. A hydrophilic layer surrounds the polymeric beads and eliminates hydrophobic interactions with the resin, resulting in very efficient peaks. A proprietary grafted cation-exchange surface provides pH selectivity control for high-resolution separations.

 
產品號碼
082515
Unit Size
Each
Particle Size
5 μm
Diameter (Metric)
2.1 mm
Length (Metric)
250 mm
價格 (HKD)
完整規格
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.28 mL/min
Length (Metric)250 mm
Max. Pressure7000 psi (480 bar)
Particle Size5 μm
pH2 to 12
Pore SizeNonporous
Temperature60°C
Stationary PhaseSulfonate
Product LineMAbPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
產品號碼
Unit Size
Each
Particle Size
5 μm
Diameter (Metric)
2.1 mm
Length (Metric)
150 mm
價格 (HKD)
完整規格
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.46 mL/min
Length (Metric)150 mm
Max. Pressure7000 psi (480 bar)
Particle Size5 μm
pH2 to 12
Pore SizeNonporous
TemperatureAmbient to 60°C
Stationary PhaseSulfonate
Product LineMAbPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
產品號碼
Unit Size
Each
Particle Size
5 μm
Diameter (Metric)
2.1 mm
Length (Metric)
50 mm
價格 (HKD)
完整規格
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.5 mL/min
Length (Metric)50 mm
Max. Pressure7000 psi (480 bar)
Particle Size5 μm
pH2 to 12
Pore SizeNonporous
TemperatureAmbient to 60°C
Stationary PhaseSulfonate
Product LineMAbPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
顯示 3 項,共 3 項
產品號碼規格Unit SizeParticle SizeDiameter (Metric)Length (Metric)價格 (HKD)
082515完整規格
Each5 μm2.1 mm250 mm申請報價
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.28 mL/min
Length (Metric)250 mm
Max. Pressure7000 psi (480 bar)
Particle Size5 μm
pH2 to 12
Pore SizeNonporous
Temperature60°C
Stationary PhaseSulfonate
Product LineMAbPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
088242完整規格
Each5 μm2.1 mm150 mm申請報價
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.46 mL/min
Length (Metric)150 mm
Max. Pressure7000 psi (480 bar)
Particle Size5 μm
pH2 to 12
Pore SizeNonporous
TemperatureAmbient to 60°C
Stationary PhaseSulfonate
Product LineMAbPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
082675完整規格
Each5 μm2.1 mm50 mm申請報價
Column FormatAnalytical Column
Diameter (Metric)2.1 mm
Flow Rate0.5 mL/min
Length (Metric)50 mm
Max. Pressure7000 psi (480 bar)
Particle Size5 μm
pH2 to 12
Pore SizeNonporous
TemperatureAmbient to 60°C
Stationary PhaseSulfonate
Product LineMAbPac
Packing MaterialSpherical, Nonporous Polymer
Column TypeIon Exchange
PhaseIon Exchange
TechniqueBio-LC
Unit SizeEach
顯示 3 項,共 3 項
Superior performance for mAb variant analysis
  • Exceptionally high resolution for mAb variants
  • Ideal for characterization and quality control assessment of mAbs
  • Well-suited for stability studies, mAb therapeutic method development, and high-throughput screening
  • Unmatched column-to-column and lot-to-lot reproducibility eliminates column variability as a concern in stability and QA/QC testing
  • Meets the regulatory requirements for biopharmaceutical characterization
  • Available in 3, 5, and 10μm particle sizes in standard and UHPLC formats. The smaller-particle-size columns provide the same resolution as the 10μm columns, but with significantly faster analysis time.
Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.