Obtain predictable, high-resolution, high efficiency separations of food sugars, namely mono-, di-, tri-, tetra- and pentasaccharides in various types of food samples. Thermo Scientific™ Dionex™ CarboPac™ PA210-Fast-4μm IC columns resolve and quantify glucose, galactose, fructose, sucrose, rhamnose, stachyose, raffinose, and verbascose in food and beverage samples in less than 20 minutes.

 
產品號碼
088953
Unit Size
Each
Column Type
Analytical Column
Diameter (Metric)
4 mm
Length (Metric)
150 mm
完整規格
Anion Exchange Capacity66 μeq/Column
Column ConstructionPEEK
Column TypeAnalytical Column
DescriptionCarboPac PA210-4µm Analytical Column
Column Capacity66 μeq
Flow Rate0.2 to 0.8 mL/min.
For Use With (Application)Carbohydrate Analysis
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)150 mm
Diameter (Metric)4 mm
Unit SizeEach
產品號碼
Unit Size
Each
Column Type
Guard Column
Diameter (Metric)
2 mm
Length (Metric)
30 mm
完整規格
Column ConstructionPEEK
Column TypeGuard Column
DescriptionCarboPac PA210-4µm Guard Column
Column Capacity66 μeq
Flow Rate0.2 mL/min. (Recommended)
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)CarboPac PA210-4μm Analytical Column
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)30 mm
Diameter (Metric)2 mm
Unit SizeEach
產品號碼
Unit Size
Each
Column Type
Analytical Column
Diameter (Metric)
2 mm
Length (Metric)
150 mm
完整規格
Anion Exchange Capacity17 μeq/Column
Column ConstructionPEEK
Column TypeAnalytical Column
DescriptionCarboPac PA210-4µm Analytical Column
Column Capacity66 μeq
Flow Rate0.2 mL/min. (Recommended)
For Use With (Application)Carbohydrate Analysis
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)150 mm
Diameter (Metric)2 mm
Unit SizeEach
產品號碼
Unit Size
Each
Column Type
Guard Column
Diameter (Metric)
4 mm
Length (Metric)
30 mm
完整規格
Column ConstructionPEEK
Column TypeGuard Column
DescriptionCarboPac PA210-4µm Guard Column
Column Capacity66 μeq
Flow Rate0.2 to 0.8 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)CarboPac PA210-4μm Analytical Column
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)30 mm
Diameter (Metric)4 mm
Unit SizeEach
顯示 4 項,共 4 項
產品號碼規格Unit SizeColumn TypeDiameter (Metric)Length (Metric)價格 (HKD)
088953完整規格
EachAnalytical Column4 mm150 mm與我們聯繫 ›
Anion Exchange Capacity66 μeq/Column
Column ConstructionPEEK
Column TypeAnalytical Column
DescriptionCarboPac PA210-4µm Analytical Column
Column Capacity66 μeq
Flow Rate0.2 to 0.8 mL/min.
For Use With (Application)Carbohydrate Analysis
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)150 mm
Diameter (Metric)4 mm
Unit SizeEach
088956完整規格
EachGuard Column2 mm30 mm與我們聯繫 ›
Column ConstructionPEEK
Column TypeGuard Column
DescriptionCarboPac PA210-4µm Guard Column
Column Capacity66 μeq
Flow Rate0.2 mL/min. (Recommended)
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)CarboPac PA210-4μm Analytical Column
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)30 mm
Diameter (Metric)2 mm
Unit SizeEach
088954完整規格
EachAnalytical Column2 mm150 mm與我們聯繫 ›
Anion Exchange Capacity17 μeq/Column
Column ConstructionPEEK
Column TypeAnalytical Column
DescriptionCarboPac PA210-4µm Analytical Column
Column Capacity66 μeq
Flow Rate0.2 mL/min. (Recommended)
For Use With (Application)Carbohydrate Analysis
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)150 mm
Diameter (Metric)2 mm
Unit SizeEach
088955完整規格
EachGuard Column4 mm30 mm與我們聯繫 ›
Column ConstructionPEEK
Column TypeGuard Column
DescriptionCarboPac PA210-4µm Guard Column
Column Capacity66 μeq
Flow Rate0.2 to 0.8 mL/min.
For Use With (Application)Carbohydrate Analysis
For Use With (Equipment)CarboPac PA210-4μm Analytical Column
Max. Pressure4000 psi (275 bar)
Solvent CompatibilitypH 0 to 14, 80% Compatible with Common HPLC Solvents
Particle Size4 μm
Stationary PhaseEthylvinylbenzene/Divinylbenzene Substrate
pH1 to 14
Resin Composition4 μm Diameter Ethylvinylbenzene/Divinylbenzene Substrate (55% Cross-Linking) Agglomerated with 43 nm MicroBead 6% Cross-Linked Quaternary Amine-Functionalized Latex
Temperature (Metric)30°C (Recommended)
Temperature (Metric) Max60°C
Length (Metric)30 mm
Diameter (Metric)4 mm
Unit SizeEach
顯示 4 項,共 4 項
High efficiency, and predictable separation of simple sugars
  • Separation and accurate quantification of mono-, di-, tri-, tetra- and pentasaccharides
  • Food and beverage samples

Column features
  • Anion-exchange column
  • Fast analysis and short separation times
  • High efficiency
  • High resolution
  • High reproducibility

Column Formats
  • Microbore (2mm) and standard bore (4mm) formats
  • Shorter 150mm format columns provide faster separations
  • 4μm resin particles provide more efficient separations resulting in more accurate peak integration and more reliable results

Use with PAD Systems

The Dionex CarboPac PA 210-4μm anion-exchange column is used with pulsed amperometric detection (PAD) systems and permits the direct quantification of nonderivatized carbohydrates with minimal sample preparation.

圖表

文件與下載

證書

    常見問答集 (常見問題)

    引用資料與參考文獻

    Search citations by name, author, journal title or abstract text