Thermo Scientific™

iConnect™ Thermal Conductivity Detector (TCD) for TRACE™ 1300 and 1600 Series GC

產品號碼: 19070040
Thermo Scientific™

iConnect™ Thermal Conductivity Detector (TCD) for TRACE™ 1300 and 1600 Series GC

產品號碼: 19070040

Get exceptional thermal stability and extremely fast response across a wide variety of capillary and packed column applications with the Thermo Scientific™ iConnect™ Thermal Conductivity Detector (TCD) for TRACE™ 1300 and 1600 Series GC systems. The micro-volume TCD is ideal as a general-purpose detector for industrial, petrochemical, and environmental determination of unknown samples.

FOR US ONLINE SALES ONLY

 
產品號碼
19070040
Unit Size
Each
Type
iConnect Thermal Conductivity Detector
價格 (HKD)
完整規格
TypeiConnect Thermal Conductivity Detector
Detection ModeThermal Conductivity
Dynamic Range105
Temperature RangeUp to 400°C in steps of 0.1°C
DescriptioniConnect Thermal Conductivity Detector (TCD) module
For Use With (Equipment)TRACE 1300 and 1600 Series Gas Chromatographs
Detector TypeTCD
Unit SizeEach
顯示 1 項,共 1 項
產品號碼規格Unit SizeType價格 (HKD)
19070040完整規格
EachiConnect Thermal Conductivity Detector申請報價
TypeiConnect Thermal Conductivity Detector
Detection ModeThermal Conductivity
Dynamic Range105
Temperature RangeUp to 400°C in steps of 0.1°C
DescriptioniConnect Thermal Conductivity Detector (TCD) module
For Use With (Equipment)TRACE 1300 and 1600 Series Gas Chromatographs
Detector TypeTCD
Unit SizeEach
顯示 1 項,共 1 項

Thermo Scientific “instant connect” (iConnect) injectors and detectors redefine flexibility and usability in GC and GC-MS analyses. In two minutes, without special training or tools, you can swap out these modules and reconfigure your instrument for a specific workflow or method. This unique capability can also enable continuous operation or dramatically reduce maintenance downtime — just replace dirty units with clean backups and be back to running samples again in a few minutes.

 

Fast Response, Outstanding Sensitivity

Nondestructive to samples, the iConnect TCD provides exceptional sensitivity for an extremely wide range of GC applications.

  • Compatible with 1/8 in. and 1/16 in. packed columns; optimized for capillary columns
  • Maximum Temperature: 400°C in steps of 0.1°C
  • MDL: Less than 400 pg tridecane/mL with He carrier, or less than 20 pg tridecane/s with a total flow through the cell of 3 mL/min
  • Linear Dynamic Range: 105

 

Options for Expansion

For budget-conscious labs, iConnect modules offer the flexibility to start with a single-channel instrument, and expand to multi-injector or multi-detector configurations to accommodate new applications or increased throughput requirements.