Thermo Scientific™

FH 40 G Multi-Purpose Digital Survey Meter

產品號碼: 4254002
Thermo Scientific™

FH 40 G Multi-Purpose Digital Survey Meter

產品號碼: 4254002
Serve multiple radiation detection applications with one versatile instrument. The Thermo Scientific™ FH 40 G is a wide range digital Geiger counter suitable for nearly all measurement tasks arising in radiation protection through optional plug and play probes available for neutron measurement, alpha and beta contamination readings and even to detect artificial gamma radiation in variable natural radiation fields.
 
產品號碼
4254002
Unit Size
Each
Description
Without extra earphone connection, measuring range 1 µR/h-100 R/h
價格 (HKD)
完整規格
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionWithout extra earphone connection, measuring range 1 µR/h-100 R/h
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement Range1 µR/h-100 R/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
產品號碼
Unit Size
Each
Description
Measuring range: 0.1 pSv/h-0.99 Sv/h, 36 keV to 1.3 MeV
價格 (HKD)
完整規格
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionMeasuring range: 0.1 pSv/h-0.99 Sv/h, 36 keV to 1.3 MeV
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement Range0.1 to 99 Sv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H*(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
產品號碼
Unit Size
Each
Description
Without earphone connector, measuring range up to 10 R/h
價格 (HKD)
完整規格
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionWithout earphone connector, measuring range up to 10 R/h
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 10 R/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
產品號碼
Unit Size
Each
Description
Without extra earphone connection, measuring range up to 0.1 Sv/h
價格 (HKD)
完整規格
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionWithout extra earphone connection, measuring range up to 0.1 Sv/h
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 0.1 Sv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
產品號碼
Unit Size
Each
Description
Measuring range: up to 10 R/h, calibrated in R/h; extra earphone connector
價格 (HKD)
完整規格
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionMeasuring range: up to 10 R/h, calibrated in R/h; extra earphone connector
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 10 R/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
產品號碼
Unit Size
Each
Description
Without extra earphone connector
價格 (HKD)
完整規格
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionWithout extra earphone connector
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 1 Sv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
產品號碼
Unit Size
Each
Description
Measuring range: up to 1 Sv/h; 30 keV to 4.4 MeV
價格 (HKD)
完整規格
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionMeasuring range: up to 1 Sv/h; 30 keV to 4.4 MeV
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 1 Sv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
產品號碼
Unit Size
Each
Description
Export version with selectable calibration factor
價格 (HKD)
完整規格
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionExport version with selectable calibration factor
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 100mSv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
產品號碼
Unit Size
Each
Description
No nanosievert units
價格 (HKD)
完整規格
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionNo nanosievert units
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 100mSv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
產品號碼
Unit Size
Each
Description
With extra earphone connector
價格 (HKD)
完整規格
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionWith extra earphone connector
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 100mSv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
顯示 10 項,共 20 項顯示更多內容
產品號碼規格Unit SizeDescription價格 (HKD)
4254002完整規格
EachWithout extra earphone connection, measuring range 1 µR/h-100 R/h申請報價
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionWithout extra earphone connection, measuring range 1 µR/h-100 R/h
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement Range1 µR/h-100 R/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
425400201完整規格
EachMeasuring range: 0.1 pSv/h-0.99 Sv/h, 36 keV to 1.3 MeV申請報價
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionMeasuring range: 0.1 pSv/h-0.99 Sv/h, 36 keV to 1.3 MeV
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement Range0.1 to 99 Sv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H*(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
4254004完整規格
EachWithout earphone connector, measuring range up to 10 R/h申請報價
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionWithout earphone connector, measuring range up to 10 R/h
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 10 R/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
425400401完整規格
EachWithout extra earphone connection, measuring range up to 0.1 Sv/h申請報價
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionWithout extra earphone connection, measuring range up to 0.1 Sv/h
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 0.1 Sv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
425400450完整規格
EachMeasuring range: up to 10 R/h, calibrated in R/h; extra earphone connector申請報價
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionMeasuring range: up to 10 R/h, calibrated in R/h; extra earphone connector
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 10 R/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
4254006完整規格
EachWithout extra earphone connector申請報價
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionWithout extra earphone connector
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 1 Sv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
425400650完整規格
EachMeasuring range: up to 1 Sv/h; 30 keV to 4.4 MeV申請報價
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionMeasuring range: up to 1 Sv/h; 30 keV to 4.4 MeV
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 1 Sv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
4254008完整規格
EachExport version with selectable calibration factor申請報價
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionExport version with selectable calibration factor
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 100mSv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
425400802完整規格
EachNo nanosievert units申請報價
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionNo nanosievert units
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 100mSv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
425400850完整規格
EachWith extra earphone connector申請報價
Sensitivity> 30 keV
Certifications/ComplianceMeets IP 67 requirement for waterproofing; shock-resistence / NRPB approved (UK); ICRU 39 for SI-units
DescriptionWith extra earphone connector
Energy RangeFH 40 G: 36 keV to 1.3 MeV; FH 40 G-L: 36 keV to 1.3 MeV; FH 40 G-10: 30 keV to 4.4 MeV; FH 40 GL-omega: 36 keV to 1.3 MeV
Product TypeDigital Survey Meter
Measurement RangeUp to 100mSv/h
Height (English)1.7 in.
Measured QuantityFH 40 G, FH 40 G-L, FH 40 GL-omega: Response (Roentgen) - R; FH 40 G-10: Ambient dose equivalent rate (H™(10)) - Sv
Width (Metric)7.4 cm
Weight (Metric)0.41 kg
Radiation TypeDependent on probe used
Depth (Metric)195 mm
Width (English)2.9 in.
Weight (English)0.9 lb.
Depth (English)7.7 in.
Height (Metric)4.2 cm
Dose RangeFH 40 G: 10 µR - 1000 R; FH 40 G-L, FH 40 GL-omega: 10 µR - 100 R; FH 40 G-10: 100 nSv - 10 Sv
Unit SizeEach
顯示 10 項,共 20 項顯示更多內容

The FH 40 G is a versatile multipurpose Geiger counter and area monitor that can be used with external detectors for portable and remote area monitoring applications.

  • Rugged, waterproof and reliable with very simple operation.
  • Gamma meter with internal proportional counter tube.
  • Integrated gamma dose rate measurements.
  • Interface for one optional, external plug and play probe.
  • Alarm thresholds for the internal detector and external probes of the FH 40 G are monitored simultaneously.
  • Upon connection of an external plug and play probe, the probe parameters are automatically read into the FH 40 G and the correct parameters are set.
  • High voltage generation inside the plug and play probe makes the system calibration independent of cable length.
  • Separate alarms can be set by the user for both the internal and external detectors.
  • Operational internal proportional detector and connected external detector.
  • Serial infrared interface.
  • Type tested by PTB (German version).
  • Type tested for use by German fire brigades.
  • Simultaneous operation of internal and external detectors, both dose rate and remote dose rate readings.
  • Configuration and data read out via PC.
  • Waterproof (IP 67) and shock resistant.
  • ADF mode (Advanced Digital Filter).
  • Clear, backlit LCD display.
  • Datalogging capability.
  • Internal diagnostics ensure proper functioning of the detector(s) and the electronics.
  • Designed to record up to 256 data points containing measurement number, date, time and dose rate at the internal detector and external detector, status, and optional barcode information.
  • Wide range of plug and play external probes for monitoring and detection.
  • All FH 40 G versions and external probes containing the “-10” suffix are designed to meet the energy response behavior of the new SI-units ambient dose equivalent and ambient dose equivalent rate according to ICRU 39.

Short summary of available plug and play probes:

  • Gamma dose rate measurement: FHT 192 (ionization chamber), FHZ 632 (proportional counter), FHZ 612 (wide range), FHZ 302/312 (under water nuclear power).
  • Gamma search probes: FHZ 502, 503, 512 (NaJ/BGO).
  • Contamination: FHZ 742 (Scintillator), FHZ 732 (Pancake/proportional counter), FHZ 382 (Scintiallator + Alpha/Beta discriminator via LED indication if alphas are present).
  • Aritificial radiaiton discrimination: NBR probe FHZ 672.
  • Preamplifiers for various classic probes.
  • Wide range of accessories like cables, telepoles, application specific kits, etc.
FH G and FH 40 G-L series meters (4254002, 425400201, 425400250, 425400251, 4254004, 425400401, 425400450, 425400451) are not for sale in the UK

The FH 40 G instrument is available in different versions:

FH 40 G

Measured Quantity: Roentgen (R)

Measuring Range: 1 μR/h ... 100 R/h

Energy range: 36 keV ... 1.3 MeV

Dose measuring range: 10 μR - 1000 R

FH 40 G-L

Measured Quantity: Roentgen (R)

Measuring Range: 1 μR/h ... 10 R/h

Energy range: 36 keV ... 1.3 MeV

Dose measuring range: 10 μR - 100 R

FH 40 G-10

Measured Quantity: Sievert (Sv; Ambient dose equivalent rate H*(10))

Measuring Range: 10 nSv/h ... 1 Sv/h

Energy range: 30 keV ... 4.4 MeV

Dose measuring range: 100 nSv ... 10 Sv

FH 40 G-L10

Measured Quantity: Sievert (Sv; Ambient dose equivalent rate H*(10))

Measuring Range: 10 nSv/h ... 100 mSv/h

Energy range: 30 keV ... 4.4 MeV

Dose measuring range: 100 nSv ... 1 Sv

FH 40 G-X

No internal detector, operation of external plug and play probe only

General specifications of all FH40G units

Dimensions 7.7 x 2.9 x 1.7 in. (195 x 73 x 42mm)

Weight[s] 0.9 lb. (410g)

Battery type: 2 x AA

Neutron dose rate measurement: FHT 762 WENDI-2, FHT 772 H-2 REMBALL

Neutron search probes: FHT 752 SH-2 (He-3, 2bar)

圖表

文件與下載

證書

    常見問答集 (常見問題)

    引用資料與參考文獻

    Search citations by name, author, journal title or abstract text