Thermo Scientific™

HisPur™ Ni-NTA Magnetic Beads

產品號碼: 88831
Thermo Scientific™

HisPur™ Ni-NTA Magnetic Beads

產品號碼: 88831
產品號碼
88831
包裝規格
2 mL
價格 (HKD)
價格 2,692.00
線上優惠 2,047.00
(31-Aug-2024 結束)
您的價格
供應狀況
***
數量
產品號碼
包裝規格
10 mL
價格 (HKD)
價格 10,000.00
您的價格
供應狀況
***
數量
產品號碼包裝規格價格 (HKD)供應狀況數量
888312 mL
價格 2,692.00
線上優惠 2,047.00
(31-Aug-2024 結束)
您的價格
***
8883210 mL
價格 10,000.00
您的價格
***
產品概覽
圖表
影片
建議
建議
文件
常見問題
引用資料與參考文獻
其他資訊
建議
Thermo Scientific HisPur Ni-NTA Magnetic Beads are high-capacity nickel-IMAC beads for affinity purification of His-tagged fusion proteins in manual or automated formats.

Features of HisPur Ni-NTA Magnetic Beads:

High capacity—equivalent or higher binding capacity than Ni-NTA magnetic beads from other suppliers
Low nonspecific binding—the bead surface is pre-blocked and the protocol provides optimized buffers for purification
Fast—protocol is completed in 1 hour
Scalable—process microliter to milliliter sample volumes
Versatile—purify proteins using native or denaturing conditions
Reagent compatible—can be used with common cell lysis reagents and a variety of buffer additives
Multiple formats—protein coupling to the beads and downstream applications can be performed both manually and on an automated platform (e.g., Thermo Scientific KingFisher Instruments)

The blocked magnetic bead surface is derivatized with the nitrilotriacetic acid (NTA) chelation moiety and loaded with divalent nickel ions (Ni2+). The immobilized metal affinity chromatography (IMAC) beads provide high binding capacity with very low background. The HisPur Ni-NTA Magnetic Beads can be used both manually with a magnetic stand as well as with automated platforms such as the Thermo Scientific KingFisher Instruments for high-throughput needs.

HisPur Ni-NTA Magnetic Beads are used for small scale affinity purification as well as high-throughput screening of recombinant His-tagged proteins. The polyhistidine tag is the most popular affinity tag and typically consists of six consecutive histidine residues (6xHis). These tagged proteins are overexpressed in a number of different systems, most commonly in bacteria, and purified from cell lysates such as those prepared using B-PER Bacterial Protein Extraction Reagents. Purification of His-tagged proteins is achieved using a NTA chelate charged with nickel that coordinates with the histidine side chains. The NTA chelate contains four metal-binding sites which allow for low metal ion leaching and high binding capacity. The protocol for the HisPur Ni-NTA Magnetic Beads has been optimized to allow for high purity of the isolated His-tagged protein. Performance is equivalent to or better than Ni-NTA magnetic beads from other suppliers.
For Research Use Only. Not for use in diagnostic procedures.

規格

Form
Liquid
Product Line
HisPur™
Quantity
2 mL
Protein Form
Recombinant
Target
His
Type
Magnetic Affinity Bead
Ligand Type
Nickel-NTA

內容物與存放

Store at 4°C

圖表

文件與下載

證書

    常見問答集 (常見問題)

    引用資料與參考文獻

    Search citations by name, author, journal title or abstract text