Record accurate and reliable pH, mV, ORP and temperature measurements with the Thermo Scientific™ Orion Star™ A211 Benchtop pH Meter. This meter is ideal for a wide range of applications and advanced pH analysis in the lab. Perform up to a 5 point pH calibration, log up to 2000 data point sets with time/date stamp and easily transfer calibration and data logs via USB or RS232 to a printer or computer with free downloadable Orion Star™ Com software. Use the included electrode stand to easily place sensors in samples and simplify storage to minimize breakage.
產品號碼
STARA2110
Unit Size
Each
Description
Orion Star A211 pH benchtop meter with stand
Includes
Star A211 pH meter, electrode stand, 100-240V universal power adapter, computer cable
價格 (HKD)
價格 11,492.00
您的價格
供應狀況
***
完整規格
數量
Accuracy (Temperature)
±0.1°C
Accuracy (mV)
±0.2 or ±0.05%, whichever is greater
Accuracy (pH)
±0.002
Data Management Details
Transfer single, range or all data points to printer or computer
Description
Orion Star A211 pH benchtop meter with stand
Outputs
USB, RS-232
Includes
Star A211 pH meter, electrode stand, 100-240V universal power adapter, computer cable
Measurement Modes
pH, mV, Relative mV, ORP with Temperature
Calibration
pH with calibration editing option, relative mV, ORP and temperature
Range (pH)
-2 to 20
Resolution (pH)
0.001, 0.01, 0.1
Range (mV)
±2000.0
Range (ORP)
±2000.0mV
Resolution (mV)
0.1mV
Calibration Points
1 to 5
Temperature Range (Metric)
-5°C to +105°C
Temperature Range (English)
22.0°F to 221.0°F
Resolution (Temperature)
0.1°C, 0.1°F
Temperature Selection
Manual or automatic with ATC temperature probe
Temperature Probe Calibration
1 point temperature offset calibration
Display Type
LCD, Graphic with Backlight
Backlight Option
Yes, selectable
Memory
Non-volatile memory preserves data log, calibration log and meter settings
Data Points
2000 with Date and Time Stamp
Log Function Type
Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode
Alarm Output
High/low limit alarm, calibration due alarm
Inputs
BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
Certifications/Compliance
CE, TUV 3-1, FCC Class A
IP Rating
IP-54
AC Adapter
Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003)
Dimensions (L x W x H)
24 cm x 18 cm x 11 cm (9.5 in. x 7.1 in. x 4.3 in.)
Weight (Metric)
0.9 kg
Weight (English)
2 lb.
Warranty
3 Year Meter Warranty
Keypad
Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys
Methods
10 per channel with password protection
Model
Orion Star A211 pH/mV/RmV/ORP/Temperature Benchtop Meter
Power Supply
Universal AC adapter (included) or 4 AA batteries (sold separately)
Orion Star A211 pH benchtop meter durable sensor TRIS kit with TRIS-compatible ROSS Ultra epoxy-body pH/ATC electrode
Star A211 pH meter, 8157BNUMD ROSS Ultra epoxy-body pH/ATC electrode, 810199 pH buffer kit, electrode stand, 100-240V universal power adapter, computer cable
價格 13,754.00
您的價格
***
Accuracy (Temperature)
±0.1°C
Accuracy (mV)
±0.2 or ±0.05%, whichever is greater
Accuracy (pH)
±0.002
Data Management Details
Transfer single, range or all data points to printer or computer
Description
Orion Star A211 pH benchtop meter durable sensor TRIS kit with TRIS-compatible ROSS Ultra epoxy-body pH/ATC electrode
Outputs
USB, RS-232
Includes
Star A211 pH meter, 8157BNUMD ROSS Ultra epoxy-body pH/ATC electrode, 810199 pH buffer kit, electrode stand, 100-240V universal power adapter, computer cable
Measurement Modes
pH, mV, Relative mV, ORP with Temperature
Calibration
pH with calibration editing option, relative mV, ORP and temperature
Range (pH)
-2 to 20
Resolution (pH)
0.001, 0.01, 0.1
Range (mV)
±2000.0
Range (ORP)
±2000.0mV
Resolution (mV)
0.1mV
Calibration Points
1 to 5
Temperature Range (Metric)
-5°C to +105°C
Temperature Range (English)
22.0°F to 221.0°F
Resolution (Temperature)
0.1°C, 0.1°F
Temperature Selection
Manual or automatic with ATC temperature probe
Temperature Probe Calibration
1 point temperature offset calibration
Display Type
LCD, Graphic with Backlight
Backlight Option
Yes, selectable
Memory
Non-volatile memory preserves data log, calibration log and meter settings
Data Points
2000 with Date and Time Stamp
Log Function Type
Automatic with Auto-Read and Timed Read Modes, Manual with Continuous Read Mode
Alarm Output
High/low limit alarm, calibration due alarm
Inputs
BNC (pH or ORP electrode), pin-tip (reference electrode), 8 pin MiniDIN (ATC temperature probe), stirrer input (stirrer probe)
Certifications/Compliance
CE, TUV 3-1, FCC Class A
IP Rating
IP-54
AC Adapter
Universal 50-60 Hz, 100-240 VAC power adapter (Cat. No. 1010003)
Dimensions (L x W x H)
24 cm x 18 cm x 11 cm (9.5 in. x 7.1 in. x 4.3 in.)
Weight (Metric)
0.9 kg
Weight (English)
2 lb.
Warranty
3 Year Meter Warranty
Keypad
Comprehensive with menu-specific function keys and dual purpose scroll/shortcut keys
Methods
10 per channel with password protection
Model
Orion Star A211 pH/mV/RmV/ORP/Temperature Benchtop Meter
Power Supply
Universal AC adapter (included) or 4 AA batteries (sold separately)
Probe Type
pH electrode, ORP electrode, reference half-cell electrode, ATC temperature probe, stirrer probe (includes 8157BNUMD ROSS Ultra Triode pH/ATC electrode)
Languages
English, Spanish, French, Italian, German and Chinese; Portuguese and Korean Available with Software Update
Range (Relative mV)
±2000.0mV
Relative Humidity Range
5 to 85%, non-condensing
Isopotential Point
7.000pH
Stability
Selectable fast, medium, slow or Smart Stability setting; Selectable off or Automatic Smart averaging setting
Temperature (English) Operating
41°F to 113°F (ambient)
Temperature (Metric) Operating
5°C to 45°C (ambient)
Channels
1
Battery Type
4 x AA (sold separately)
Battery Life
800 hr.
Unit Size
Each
顯示 7 項,共 7 項
Thermo Scientific Orion Star A211 Benchtop pH Meters are easy-to-use, dependable laboratory meters with advanced features and functions. Selectable read modes and stability indicator give you flexibility and control over your testing. All critical data is shown with your measurements including temperature, date and time, read type, measurement stability, active calibration information and electrode condition icon. Onscreen calibration and setup instructions can be displayed in several local languages with new languages added through software updates. Navigation is fast and simple due to the comprehensive keypad with menu-specific function keys, dual purpose scroll/shortcut keys, plus power, measure, log view and stirrer keys that ensure easy operation. All setup menus are in one location with direct access using a single shortcut key so you can quickly access, evaluate and change measurement and instrument settings.
Measure pH, mV, relative mV or ORP with temperature
Perform up to a 5 point pH calibration using automatic buffer recognition of NIST or DIN buffer groups with choice to manually enter custom buffer values
Calibration editing option allows individual points to be fixed without a full recalibration
Capture your critical readings with measurement stability indicator and selectable read modes — Auto-Read holds a stable reading, Continuous shows changing readings with hold option and Timed logs data at specific intervals
Eliminate the need for magnetic stir bars using the meter-controlled stirrer probe (catalog number 096019) to uniformly mix solutions
Data log collects and date/time stamps up to 2000 measurement sets with optional sample ID and user ID
Calibration log stores 10 most recent calibrations
Non-volatile meter memory ensures your data and settings are protected, even with loss of power
Orion Star Com software facilitates data transfer to a computer via USB or RS232 connections
Flexible power options with universal power adapter or optional AA batteries
IP54-rated housing resists dust and splashes and can be wall-mounted if table space is limited
Meters include CE, TUV 3-in-1 and FCC Class A certifications
3-year replacement warranty
Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.