Save time and money while achieving fast, accurate measurements in a variety of samples with the Thermo Scientific™ Orion™ pHR Process ROSS™ Electrode. With minimal maintenance and a longer lifetime, this product offers superior performance, reliability and longevity for a variety of applications, including pure water. The double junction design with replaceable salt bridge lengthens electrode life providing better value. When performance starts to degrade, simply remove and replace the old salt bridge and electrolyte to rejuvinate response.
Description | pHR Salt Bridge, Quantity: 3 |
Type | Salt Bridge |
Certifications/Compliance | Certificate of Analysis (COA), Certificate of Conformance (COC) |
Unit Size | Each |
Description | pHR Reference Fill Solution Bridge |
Type | Fill Solution Bridge |
Certifications/Compliance | Certificate of Analysis (COA), Certificate of Conformance (COC) |
Unit Size | Each |
Description | pHR Salt Bridge, Quantity: 1 |
Type | Salt Bridge |
Certifications/Compliance | Certificate of Analysis (COA), Certificate of Conformance (COC) |
Unit Size | Each |
Description | pHR Reference Fill Solution Bridge, without pre-amplifier; 15 ft. cable |
Type | Fill Solution Bridge |
Includes | without pre-amplifier; 15 ft. cable |
Length (English) Cable | 15 ft. |
Length (Metric) Cable | 4.57 m |
Max. Flow Rate | 10 ft./sec. |
Max. Transmission Distance | 3000 ft. (914m) |
Offset | 0±25mV |
pH Range | 0 to 14 |
pH Measurement Response | 30 seconds for 95% of change for a ±3 pH change |
pH Measurement Repeatability | ±0.075 |
Pressure Range | 0 to 100psig |
Slope | 92 to 102% |
Temperature (Metric) Range | 0°C to 95°C |
Temperature Repeatability | ±0.5°C |
Temperature Response | <3 minutes for 90% change for a 10°C temperature change |
Certifications/Compliance | Certificate of Analysis (COA), Certificate of Conformance (COC) |
Unit Size | Each |
Contains | Pre-amplifier |
Description | pHR Reference Fill Solution Bridge, with pre-amplifier; 10 ft. cable |
Type | Fill Solution Bridge with Pre-amplifier |
Includes | with pre-amplifier; 10 ft. cable |
Length (English) Cable | 10 ft. |
Length (Metric) Cable | 4.57 m |
Max. Flow Rate | 3.05 ft./sec. |
Max. Transmission Distance | 3000 ft. (914m) |
Offset | 0±25mV |
pH Range | 0 to 14 |
pH Measurement Response | 30 seconds for 95% of change for a ±3 pH change |
pH Measurement Repeatability | ±0.075 |
Pressure Range | 0 to 100psig |
Slope | 92 to 102% |
Temperature (Metric) Range | 0°C to 95°C |
Temperature Repeatability | ±0.5°C |
Temperature Response | <3 minutes for 90% change for a 10°C temperature change |
Certifications/Compliance | Certificate of Analysis (COA), Certificate of Conformance (COC) |
For Use With (Equipment) | pHR process ROSS electrode |
Unit Size | Each |
Contains | Pre-amplifier |
Description | pHR Reference Fill Solution Bridge, with pre-amplifier; 20 ft. cable |
Type | Fill Solution Bridge with Pre-amplifier |
Includes | with pre-amplifier; 20 ft. cable |
Length (English) Cable | 20 ft. |
Length (Metric) Cable | 6.1 m |
Max. Flow Rate | 3.05 ft./sec. |
Max. Transmission Distance | 3000 ft. (914m) |
Offset | 0±25mV |
pH Range | 0 to 14 |
pH Measurement Response | 30 seconds for 95% of change for a ±3 pH change |
pH Measurement Repeatability | ±0.075 |
Pressure Range | 0 to 100psig |
Slope | 92 to 102% |
Temperature (Metric) Range | 0°C to 95°C |
Temperature Repeatability | ±0.5°C |
Temperature Response | <3 minutes for 90% change for a 10°C temperature change |
Certifications/Compliance | Certificate of Analysis (COA), Certificate of Conformance (COC) |
For Use With (Equipment) | pHR process ROSS electrode |
Unit Size | Each |
Contains | Pre-amplifier |
Description | pHR Reference Fill Solution Bridge, with pre-amplifier; 30 ft. cable |
Type | Fill Solution Bridge with Pre-amplifier |
Includes | with pre-amplifier; 30 ft. cable |
Length (English) Cable | 30 ft. |
Length (Metric) Cable | 6.1 m |
Max. Flow Rate | 9.1 ft./sec. |
Max. Transmission Distance | 3000 ft. (914m) |
Offset | 0±25mV |
pH Range | 0 to 14 |
pH Measurement Response | 30 seconds for 95% of change for a ±3 pH change |
pH Measurement Repeatability | ±0.075 |
Pressure Range | 0 to 100psig |
Slope | 92 to 102% |
Temperature (Metric) Range | 0°C to 95°C |
Temperature Repeatability | ±0.5°C |
Temperature Response | <3 minutes for 90% change for a 10°C temperature change |
Certifications/Compliance | Certificate of Analysis (COA), Certificate of Conformance (COC) |
Unit Size | Each |
Catalog Number | Specifications | Unit Size | Description | Price (KRW) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
SBPHR-3 | Each | pHR Salt Bridge, Quantity: 3 | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
RCPHR-60 | Each | pHR Reference Fill Solution Bridge | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SBPHR-1 | Each | pHR Salt Bridge, Quantity: 1 | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SH36A9E115 | Each | pHR Reference Fill Solution Bridge, without pre-amplifier; 15 ft. cable | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SH36A9E210 | Each | pHR Reference Fill Solution Bridge, with pre-amplifier; 10 ft. cable | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SH36A9E220 | Each | pHR Reference Fill Solution Bridge, with pre-amplifier; 20 ft. cable | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SH36A9E230 | Each | pHR Reference Fill Solution Bridge, with pre-amplifier; 30 ft. cable | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The ROSS™ reference system provides a drift-free measurement system with accurate results.
Features:
Benefits: