Use the Orion Star T930 ion titrator for dedicated ion titrations including salt in foods, chloride in drinking and wastewater, ammonia of wastewater, surfactants in consumer products and total hardness of water. Titration techniques include equivalence point titrations and preset mV endpoint titrations plus multiple known addition (MKA) mode. Using MKA mode, the titrator performs an automated calibration and calculation of sample concentration by adding aliquots of standard to sample, removing the need for a separate calibration and minimizing matrix effects.
Catalog Number
START9305
Unit Size
Each
Description
Orion Star T930 ion titrator surfactant kit
Includes
9342BN surfactant electrode, 900200 reference electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240V power supplies
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator surfactant kit
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentration titrations including surfactants in consumer products
Includes
9342BN surfactant electrode, 900200 reference electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, literature on USB drive, 110-240V power supplies
Price (KRW)
Price: 7,030,000
Your price:
Availability
***
Full specifications
Quantity
Accuracy (ISE)
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator without electrode
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentration titrations including salt in food products, calcium in juice and milk, total hardness of drinking water and wastewater, chloride in drinking water and wastewater, ammonia and Total Kjeldahl Nitrogen (TKN) of wastewater and surfactants in consumer products
Includes
20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, literature on USB drive, 110-240V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
9780SC silver billet electrode, 91CBNC electrode cable, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, literature on USB drive, 110-240V power supplies
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator salt content kit
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentration titrations including salt in food products, chloride in drinking water and wastewater.
Includes
9780SC silver billet electrode, 91CBNC electrode cable, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, literature on USB drive, 110-240V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
8611BNWP ROSS sodium electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, pint bottle cap, computer cable, USB drive, 110-240 V power supplies
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator sodium MKA kit
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentrations analysis using multiple known addition (automated calibration and calculation of sample concentration) to determine sodium concentrations
Includes
8611BNWP ROSS sodium electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, pint bottle cap, computer cable, USB drive, 110-240 V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
9512HPBNWP high performance ammonia electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, pint bottle cap, computer cable, USB drive, 110-240 V power supplies
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator ammonia MKA kit
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentrations analysis using multiple known addition (automated calibration and calculation of sample concentration) to determine ammonia concentrations
Includes
9512HPBNWP high performance ammonia electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, pint bottle cap, computer cable, USB drive, 110-240 V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
9720BNWP calcium electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240V power supplies
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator total hardness kit
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentration titrations including calcium hardness of drinking water and wastewater and total hardness of drinking water and wastewater
Includes
9720BNWP calcium electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
Titration Process Control
Routine, quick, careful or user defined
Titration Setup Wizard
Yes, using Start a New Titration workflow
Titration Technique
Equivalence point or preset endpoint
Titration Types
Direct or back titration
Updateable Firmware
Yes, using USB flash drive
Warranty
1 year replacement warranty
Dimensions (L x W x H)
10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm
Electrical Requirements
100-240V, 50/60 Hz
Unit Size
Each
Showing 6 of 6
Catalog Number
Specifications
Unit Size
Description
Includes
Price (KRW)
Availability
Quantity
START9305
Full specifications
Each
Orion Star T930 ion titrator surfactant kit
9342BN surfactant electrode, 900200 reference electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240V power supplies
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator surfactant kit
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentration titrations including surfactants in consumer products
Includes
9342BN surfactant electrode, 900200 reference electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, literature on USB drive, 110-240V power supplies
Price: 7,030,000
Your price:
***
Accuracy (ISE)
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator without electrode
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentration titrations including salt in food products, calcium in juice and milk, total hardness of drinking water and wastewater, chloride in drinking water and wastewater, ammonia and Total Kjeldahl Nitrogen (TKN) of wastewater and surfactants in consumer products
Includes
20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, literature on USB drive, 110-240V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
9780SC silver billet electrode, 91CBNC electrode cable, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, literature on USB drive, 110-240V power supplies
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator salt content kit
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentration titrations including salt in food products, chloride in drinking water and wastewater.
Includes
9780SC silver billet electrode, 91CBNC electrode cable, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, literature on USB drive, 110-240V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
8611BNWP ROSS sodium electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, pint bottle cap, computer cable, USB drive, 110-240 V power supplies
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator sodium MKA kit
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentrations analysis using multiple known addition (automated calibration and calculation of sample concentration) to determine sodium concentrations
Includes
8611BNWP ROSS sodium electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, pint bottle cap, computer cable, USB drive, 110-240 V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
9512HPBNWP high performance ammonia electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, pint bottle cap, computer cable, USB drive, 110-240 V power supplies
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator ammonia MKA kit
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentrations analysis using multiple known addition (automated calibration and calculation of sample concentration) to determine ammonia concentrations
Includes
9512HPBNWP high performance ammonia electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, pint bottle cap, computer cable, USB drive, 110-240 V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
9720BNWP calcium electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240V power supplies
±0.2 mV or ±0.05% of reading, whichever is greater
Burette Functions
Automatic rinse cycles for flushing and discrete dispense volume with continuous option; Exceeds acc
Functions Available
Sample titration, titrant standardization, calibration and direct measure
Accuracy (mV)
±0.2 mV
Accuracy (Temperature)
±0.2 °C
Advanced ISE Functions
Multiple known addition (MKA); automated calibration and calculation of sample concentration by adding aliquots of standard to sample using the burette
Alarm Output
Notifications for Titration Cycle Complete, Maximum Titrant Volume, Data Log Full, Calibration Due, Maintenance Reminder
Backlight Option
Yes, adjustable
Blank Options
Fixed value or variable value using titration
Burette Sizes
10 mL, 20 mL (included) or 50 mL
Calibration
Ion concentration (ISE) and temperature
Calibration Points (ISE)
1 to 5
Certifications/Compliance
CE, TUV 3-in-1, FCC, EN/EIC61326-1, IEC 61010
Channels
1
Cycles Per Titration Run
1 to 5 cycles, option to exclude cycle results from average results and RSD calculations
Data Management Details
Data log export as CSV or PDF file, short or long format
Data Points
100 data sets each: sample titration, titrant standardization, calibration and direct measure
Description
Orion Star T930 ion titrator total hardness kit
Display Type
5.7” color capacitive touchscreen, 640 x 480 resolution
Type
Ion titrator
Equivalence Points
1 to 2
For Use With (Application)
Ion concentration titrations including calcium hardness of drinking water and wastewater and total hardness of drinking water and wastewater
Includes
9720BNWP calcium electrode, 20mL burette, stirrer probe, dispenser probe, standard tubing kit, 1L plastic bottle, GL38 bottle cap with two ports and drying tube, computer cable, USB drive, 110-240V power supplies
Chinese, English, French, German, Italian, Japanese, Korean, Portuguese and Spanish
Material
ABS Plastic
Memory
Non-volatile memory preserves data logs and settings
Methods
Up to 10 methods with optional password protection; import/export methods via USB flash drive
Model
Orion Star T930
Outputs
3 USB ports for printer, USB flash drive and computer software connections
Precision
0.5% RSD, dependent on environment and handling conditions
Preset Endpoints
1 to 3
Probe Type
Ion selective electrode (ISE), reference half-cell electrode, ATC temperature probe, stirrer probe
Range (ISE)
0.0001 to 19990
Range (mV)
-2000.0 to +2000.0 mV
Relative Humidity Range
5 to 85%, non-condensing
Resolution
Burette drive offers advanced micro-step technology that provides 25,600 micro-steps per motor revolution for smooth and precise burette positioning (over 2 million micro-steps over the full burette stroke range)
Resolution (ISE)
0.0001 minimum, 1 to 4 significant digits (user selectable)
Resolution (mV)
0.1 mV
Resolution (Temperature)
0.1 °C
Sample ID
Auto-incremental, manual or off
Stirrer Probe Speeds
5 user selectable speeds (250 to 3700 RPM)
Temperature (English) Operating
41°F to 104°F
Temperature (Metric) Operating
5°C to 40°C
Temperature Probe Calibration
Optional 1 point offset calibration
Temperature Range (Metric)
-5.0°C to +100.0°C
Temperature Selection
Manual or automatic
Time and Date
Yes, with nonvolatile battery backup
Titrant Determination
Standardization titration or manual concentration input
Titration Process Control
Routine, quick, careful or user defined
Titration Setup Wizard
Yes, using Start a New Titration workflow
Titration Technique
Equivalence point or preset endpoint
Titration Types
Direct or back titration
Updateable Firmware
Yes, using USB flash drive
Warranty
1 year replacement warranty
Dimensions (L x W x H)
10” x 16” x 14”; 25.4 cm x 40.6 cm x 35.6 cm
Electrical Requirements
100-240V, 50/60 Hz
Unit Size
Each
Showing 6 of 6
Accurate, reproducible results: Automating the titration workflow enables analysis to be run using the same setup parameters and calculations every time
Faster setup time: Setup and save electrode, titrant and titration parameters once using methods
Improved lab throughput: Start the titration and let the instrument run unattended
Reduced cost and downtime: Easily replace titrator parts to minimize maintenance downtime while long lasting electrodes reduce the cost of ownership
Securely document test results: View results live, in the summary table and within the 100 point data log
Applications database: Tested and validated preprogrammed methods can be loaded onto your titrator
Pair the titrator option with any of our premium Orion ion selective electrodes or select one of our preconfigured titrator and electrode kits for a bundled discount