Thermo Scientific™

Dionex™ Retention Time Standards for Ion Chromatography

카탈로그 번호: 088957
Thermo Scientific™

Dionex™ Retention Time Standards for Ion Chromatography

카탈로그 번호: 088957

Automate the task of entering and updating component retention times and names using Thermo Scientific™ Dionex™ Retention Time Standards for ion chromatography. Available for both anion and cation analyses, these standards contain specific ratios of analytes and have been developed for use with Thermo Scientific™ Dionex™ Chromeleon™ 7.2 software retention time standard (RTS) processing methods.

 
카탈로그 번호
088957
제품 사이즈
Each 1
표준 농도
Low
용도(애플리케이션)
Routine Anion Determinations
표준 구성요소
Fluoride, Chloride, Nitrite, Bromide, Nitrate, Phosphate
제품 정가(KRW)
전체 사양
유형Standard
표준 농도Low
표준 구성요소Fluoride, Chloride, Nitrite, Bromide, Nitrate, Phosphate
용도(애플리케이션)Routine Anion Determinations
부피(미터법)50 mL
스토리지Room Temperature
Unit SizeEach 1
카탈로그 번호
제품 사이즈
Each 1
표준 농도
High
용도(애플리케이션)
Routine Anion Determinations
표준 구성요소
Fluoride, Chloride, Nitrite, Bromide, Nitrate, Phosphate
제품 정가(KRW)
전체 사양
유형Standard
표준 농도High
표준 구성요소Fluoride, Chloride, Nitrite, Bromide, Nitrate, Phosphate
용도(애플리케이션)Routine Anion Determinations
부피(미터법)50 mL
스토리지Room Temperature
Unit SizeEach 1
카탈로그 번호
제품 사이즈
Each
표준 농도
Low
용도(애플리케이션)
Routine Cation Determinations
표준 구성요소
Lithium, Sodium, Ammonium, Potassium, Magnesium, Calcium
제품 정가(KRW)
전체 사양
유형Standard
표준 농도Low
표준 구성요소Lithium, Sodium, Ammonium, Potassium, Magnesium, Calcium
용도(애플리케이션)Routine Cation Determinations
부피(미터법)50 mL
스토리지Room Temperature
Unit SizeEach
카탈로그 번호
제품 사이즈
Each
표준 농도
High
용도(애플리케이션)
Routine Cation Determinations
표준 구성요소
Lithium, Sodium, Ammonium, Potassium, Magnesium, Calcium
제품 정가(KRW)
전체 사양
유형Standard
표준 농도High
표준 구성요소Lithium, Sodium, Ammonium, Potassium, Magnesium, Calcium
용도(애플리케이션)Routine Cation Determinations
부피(미터법)50 mL
스토리지Room Temperature
Unit SizeEach
4 / 4 표시
카탈로그 번호사양제품 사이즈표준 농도용도(애플리케이션)표준 구성요소제품 정가(KRW)
088957전체 사양
Each 1LowRoutine Anion DeterminationsFluoride, Chloride, Nitrite, Bromide, Nitrate, Phosphate연락처 ›
유형Standard
표준 농도Low
표준 구성요소Fluoride, Chloride, Nitrite, Bromide, Nitrate, Phosphate
용도(애플리케이션)Routine Anion Determinations
부피(미터법)50 mL
스토리지Room Temperature
Unit SizeEach 1
302511전체 사양
Each 1HighRoutine Anion DeterminationsFluoride, Chloride, Nitrite, Bromide, Nitrate, Phosphate연락처 ›
유형Standard
표준 농도High
표준 구성요소Fluoride, Chloride, Nitrite, Bromide, Nitrate, Phosphate
용도(애플리케이션)Routine Anion Determinations
부피(미터법)50 mL
스토리지Room Temperature
Unit SizeEach 1
088964전체 사양
EachLowRoutine Cation DeterminationsLithium, Sodium, Ammonium, Potassium, Magnesium, Calcium연락처 ›
유형Standard
표준 농도Low
표준 구성요소Lithium, Sodium, Ammonium, Potassium, Magnesium, Calcium
용도(애플리케이션)Routine Cation Determinations
부피(미터법)50 mL
스토리지Room Temperature
Unit SizeEach
088969전체 사양
EachHighRoutine Cation DeterminationsLithium, Sodium, Ammonium, Potassium, Magnesium, Calcium연락처 ›
유형Standard
표준 농도High
표준 구성요소Lithium, Sodium, Ammonium, Potassium, Magnesium, Calcium
용도(애플리케이션)Routine Cation Determinations
부피(미터법)50 mL
스토리지Room Temperature
Unit SizeEach
4 / 4 표시
How do they work?

Predefined components with assigned retention times are interpreted as peak area ratios. The peak area ratio for a component is its peak area percentage relative to the largest peak in the retention time standard. For example, if the largest peak has an area of 0.09, and peak 5 has an area of 0.045, then the ratio of peak 5 to the reference (largest) peak is 50%. Peak area ratios allow dynamic determination of expected component retention times. Even with a shift in retention time, Chromeleon software automatically recognizes and correctly assigns components based on these peak area ratios.

When a sequence is run, the retention time standard is included in the run and the injection is identified as a retention time standard. When the sequence data is processed, Chromeleon verifies that the retention time standard is valid based on predefined criteria. For each injection in a sequence that is assigned an RTS processing method, Chromeleon searches for the first valid retention time standard with the same assigned processing method. This is designated as the reference retention time standard for the injection. The retention times of the identified components from the reference retention time standard are then used as the expected retention times to identify components in unknown injections that reference this retention time standard.


Increase Your Productivity
  • Dynamic determination of expected retention times based on peak area ratios.
  • Easy and convenient IC standard preparation.
  • Reduce standard preparation time.
  • Reduce time-consuming standard validation.
  • Reduce time required to compensate for factors like variations in run conditions.
  • Easy access to default method templates that contain predefined component names and peak ratios using Chromeleon 7.2 SR3 or later.

Guarantee the Reliability of Your Analyses
  • Reduce standard preparation errors.
  • Increase accuracy of quantifications.
  • Improve day-to-day reproducibility.

The Quality You Expect from Thermo Fisher Scientific
  • Uses only high-purity, reagent-grade chemicals and water (18MΩ-cm), quality-control checked for ionic contamination.
  • All standards are National Institute of Standards and Technology (NIST) traceable.
  • A Certificate of Analysis is provided with every standard.

Unconditional Guarantee

Your satisfaction is guaranteed. All Thermo Scientific Dionex standards carry a 90-day warranty.

Limited warranty period: Subject to all warranty requirements and exclusions set out in our Terms and Conditions of Sale, this product is warranted from the date we ship the product and for ninety (90) days thereafter. Disclaimer to internal research use restriction: Any restrictions on the purchaser to utilize the product(s) for internal research purposes only does not apply to the product(s) on the web pages associated with this statement.