LightShift™ EMSA Optimization and Control Kit
LightShift™ EMSA Optimization and Control Kit
LightShift™ EMSA Optimization and Control Kit
LightShift™ EMSA Optimization and Control Kit
Thermo Scientific™

LightShift™ EMSA Optimization and Control Kit

Thermo Scientific LightShift EMSA Optimization and Control Kit는 EMSA(electrophoretic mobility shift assay)를 실행하여 단백질-DNA 결합 상호작용을 확인하고 특성을 분석하는 매우자세히 알아보기
Have Questions?
카탈로그 번호수량
20148X100 Reactions
카탈로그 번호 20148X
제품 가격(KRW)
289,000
Online offer
Ends: 31-Dec-2025
321,000
할인액 32,000 (10%)
Each
카트에 추가하기
수량:
100 Reactions
대량 주문 또는 맞춤형 요청
제품 가격(KRW)
289,000
Online offer
Ends: 31-Dec-2025
321,000
할인액 32,000 (10%)
Each
카트에 추가하기
Thermo Scientific LightShift EMSA Optimization and Control Kit는 EMSA(electrophoretic mobility shift assay)를 실행하여 단백질-DNA 결합 상호작용을 확인하고 특성을 분석하는 매우 견고하고 민감도 높은 시스템입니다. 이 키트에는 DNA 결합 상호작용을 설정하고 맞춤화하는 시약뿐 아니라, DNA와 단백질 추출물로 구성된 대조군 세트가 들어 있어 키트 시스템을 검사할 수 있습니다.

LightShift EMSA Optimization and Control Kit의 특징:

• 핵 추출물에서 미량 단백질을 검출하는 우수한 성능
• 방사성 방식과 다이곡시제닌(digoxigenin) 방식보다 우수한 민감도
• 유명한 DNA-단백질 상호작용에 대해 이전에 수립한 결합 조건 적용 가능
• 신규 사용자가 우수한 분석법을 개발하고 결합 특이성을 확인하는데 유용한 EBNA 제어 시스템 포함

LightShift EMSA 검출 원리는 웨스턴 블롯과 비슷합니다. 말단에 바이오틴이 표지된 duplex DNA는 핵 추출물이나 정제 인자와 함께 반응시킨후, 천연 겔(native gel)에서 전기영동하여 확인합니다. 그리고 나면 DNA는 신속하게(30분) 양의 나일론 막으로 전달되고, UV 교차연결되고, streptavidin-HRP 접합체로 조사되고 나서 기질을 사용해 배양됩니다. 표지부터 결과에 이르는 프로토콜을 단 하루만에 실시할 수 있습니다.

DNA와 단백질의 상호작용은 DNA 복제, 재조합 및 수복, 전사, 바이러스 어셈블리를 포함한 많은 세포 과정을 통제하는 데 있어 핵심적인 부분입니다. 유전자 조절 연구와 단백질:DNA 상호작용 확인에 핵심적인 한 가지 기법은 EMSA(electrophoretic mobility shift assay)입니다.

EMSA 기법은 비변성 polyacrylamide 또는 agarose 겔 전기영동을 적용하면 단백질:DNA 복합체가 자유 DNA 분자보다 느리게 이동한다는 관찰을 토대로 합니다. 단백질 결합 시 DNA 이동 속도는 바뀌거나 느려지기 때문에 이 분석을 겔 전이 또는 겔 지연 분석이라고도 합니다. EMSA의 개념이 정립되기 전에는 단백질:DNA 상호작용은 주로 nitrocellulose 필터-결합 분석을 사용해 연구되었습니다.

이 분석을 실시하려면 비오틴으로 말단 표지된 정제 DNA 표적, 검사할 단백질 추출물, 나일론 막(membrane), 기본 전기영동 장비만 있으면 됩니다. DNA 표적은 5' 또는 3' 비오틴 표지로 합성되거나 Thermo Scientific Biotin 3' End DNA Labeling Kit(제품 번호 89818)를 사용해 합성한 후 표지될 수 있습니다.. 핵, 세포질, 전체 세포 단백질 추출물은 Thermo Scientific NE-PER Nuclear and Cytoplasmic Extraction Reagent Kit(제품 번호 78833)를 비롯한 다양한 방법으로 채취할 수 있습니다.

관련 자료:

단백질-핵산 상호작용 기술 가이드
단백질-DNA 상호작용 검출 기술 가이드
겔 전이 분석(EMSA) 기술 가이드

관련 제품:
Biotin 3' End DNA Labeling Kit
NE-PER Nuclear and Cytoplasmic Protein Extraction Reagent Kit
Biodyne B Nylon Membrane for Chemiluminescent EMSA
Chemiluminescent Nucleic Acid Detection Module
LightShift Chemiluminescent RNA EMSA Kit

추가 제품 데이터
Pierce G2 Fast Blotter를 사용한 Transfer EMSA 겔
For Research Use Only. Not for use in diagnostic procedures.
사양
어세이EMSA Assay
용도(장비)myECL™ Imager, X-Ray Film
포함10X Binding Buffer (1 mL), Biotin-EBNA Control DNA (50 μL), Unlabeled EBNA DNA (50 μL), EBNA Extract (125 μL), Poly dI·dC (125 μL), 50% Glycerol (500 μL), 1% NP-40 (500 μL), 1M KCl (1 mL), 100mM MgCl(500 μL), 200mM EDTA pH 8.0 (500 μL), 5X Loading Buffer (1 mL)
제품라인LightShift
제품 유형LightShift EMSA Optimization and Control Kit
수량100 Reactions
타겟 특이도Not Target-Specific
기술Gel Shift
형식Kit
Unit SizeEach
구성 및 보관
Sufficient For: 100 binding reactions
• 10X Binding Buffer, 1 mL
• Biotin-EBNA Control DNA, 50 μL
• Unlabeled EBNA DNA, 50 μL
• EBNA Extract, 125 μL
• Poly (dI·dC), 125 μL
• 50% Glycerol, 500 μL
• 1% NP-40, 500 μL
• 1 M KCl, 1 mL
• 100mM MgCl2, 500 μL
• 200mM EDTA pH 8.0, 500 μL
• 5X Loading Buffer, 1 mL

Store at -20°C.

자주 묻는 질문(FAQ)

If the LightShift Chemiluminescent EMSA kit has been improperly stored (i.e., at room temperature, -20°C or +4°C), will it still work correctly?

The LightShift Chemiluminescent EMSA Kit is composed of two sets of components that require different storage temperatures. One component set consists of the chemiluminescent substrates and various buffers that are stored at 4°C. The other component set consists of the control DNAs and various optimization reagents that are stored at -20°C. The EBNA extract must be maintained at -20°C or it will lose activity (proteins will degrade). Short-term storage (overnight) of the other kit components at temperatures ranging from room temperature to -20°C will not adversely affect kit performance.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

I am using the LightShift Chemiluminescent EMSA kit. Can I probe for the proteins by performing a Western blot?

This has not been tested but may be possible. A better alternative is to perform a DNA binding protein pull-down assay using a probe. The following journal article is a good example of how the LightShift Chemiluminescent EMSA Kit and pull-down assays were used to detect a transcription factor bound to a DNA probe: Ragione, A.L., et al. (2003), J. Biol. Chem. 278(26):23360-8.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

I am using the LightShift Chemiluminescent EMSA kit. How much protein do I need for each reaction?

The amount of protein extract needed for a binding reaction depends on how much active DNA binding protein is in the sample. The LightShift Kit is sensitive and will easily detect 5 fmol of active protein bound to 5 fmol of biotinylated probe. If the protein being studied is abundant, 0.25 µg of a cell lysate may be sufficient for each binding reaction. However, if the protein of interest is rare, 10 µg or more of cell lysate may be needed. Using a large excess of protein extract may lead to high background signal and non-specific bands.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

What is a "supershift"?

A supershift assay is a method for positively identifying a protein:DNA interaction on an EMSA. An antibody (typically 1 µg) is added to the binding reaction. During electrophoresis, the antibody:protein:DNA complex migrates slowly, causing a “supershift” compared to the “shift” caused by a protein:DNA complex. Not all antibodies will cause a supershift. Some antibodies do not bind to proteins once they are bound to DNA. Some antibodies can prevent protein:DNA interactions but can still be used to confirm the identity of a protein that causes a shift in the absence of the antibody.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Can the LightShift Chemiluminescent EMSA Kit be used to perform supershifts?

Yes, the LightShift Chemiluminescent EMSA Kit can be used to detect supershifts. However, not all antibodies will work for supershift assays. Some antibodies will prevent protein:DNA interactions. In addition, the order in which the components of the binding reaction are assembled may affect the results of a supershift assay. Generally, 1 µg antibody is added as the last component in the binding reaction. For examples of how the LightShift Chemiluminescent EMSA Kit was used to detect supershifts, see the following:

Adimoolam, S. and Ford, J.M. (2002). PNAS. 99(20):12985-90
Magid, R., et al. (2003). J. Biol. Chem. 278(35):32994-9
Ragione, F.D., et al. (2003). J. Biol. Chem. 278(26):23360-8
Rinaldi, A.L., et al. (2002). Cancer Research. 62(19):5451-6


Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

인용 및 참조 문헌 (7)

인용 및 참조 문헌
Abstract
Downregulation of ATG14 by EGR1-MIR152 sensitizes ovarian cancer cells to cisplatin-induced apoptosis by inhibiting cyto-protective autophagy.
Authors:He J, Yu JJ, Xu Q, Wang L, Zheng JZ, Liu LZ, Jiang BH
Journal:
PubMed ID:25650716
'Cisplatin is commonly used in ovarian cancer treatment by inducing apoptosis in cancer cells as a result of lethal DNA damage. However, the intrinsic and acquired resistance to cisplatin in cancer cells remains a big challenge for improving overall survival. The cyto-protective functions of autophagy in cancer cells have been ... More
Tristetraprolin suppresses the EMT through the down-regulation of Twist1 and Snail1 in cancer cells.
Authors:Yoon NA, Jo HG, Lee UH, Park JH, Yoon JE, Ryu J, Kang SS, Min YJ, Ju SA, Seo EH, Huh IY, Lee BJ, Park JW, Cho WJ
Journal:Oncotarget
PubMed ID:26840564
Inhibition of epithelial-mesenchymal transition (EMT)-inducing transcription factors Twist and Snail prevents tumor metastasis but enhances metastatic growth. Here, we report an unexpected role of a tumor suppressor tristetraprolin (TTP) in inhibiting Twist and Snail without enhancing cellular proliferation. TTP bound to the AU-rich element (ARE) within the mRNA 3'UTRs of ... More
Regulation of RIP3 by the transcription factor Sp1 and the epigenetic regulator UHRF1 modulates cancer cell necroptosis.
Authors:Yang C, Li J, Yu L, Zhang Z, Xu F, Jiang L, Zhou X, He S
Journal:Cell Death Dis
PubMed ID:28981102
Receptor-interacting kinase-3 (RIP3) is a key regulator of necroptosis. It has been shown that the expression of RIP3 is silenced in most cancer cells and tissues due to genomic methylation. However, the regulatory mechanisms controlling RIP3 expression in cancer cells have not been fully elucidated. Here, we report that Sp1, ... More
Human rickettsial pathogen modulates arthropod organic anion transporting polypeptide and tryptophan pathway for its survival in ticks.
Authors:Taank V, Dutta S, Dasgupta A, Steeves TK, Fish D, Anderson JF, Sultana H, Neelakanta G
Journal:Sci Rep
PubMed ID:29038575
The black-legged tick Ixodes scapularis transmits the human anaplasmosis agent, Anaplasma phagocytophilum. In this study, we show that A. phagocytophilum specifically up-regulates I. scapularis organic anion transporting polypeptide, isoatp4056 and kynurenine amino transferase (kat), a gene involved in the production of tryptophan metabolite xanthurenic acid (XA), for its survival in ... More
Curcumin Exerted Neuroprotection against Ozone-Induced Oxidative Damage and Decreased NF-
Authors:Nery-Flores SD, Mendoza-Magaña ML, Ramírez-Herrera MA, Ramírez-Vázquez JJ, Romero-Prado MMJ, Cortez-Álvarez CR, Ramírez-Mendoza AA
Journal:Oxid Med Cell Longev
PubMed ID:30693069
Ozone is a harmful tropospheric pollutant, causing the formation of reactive oxygen and nitrogen species that lead to oxidative damage in living beings. NF-