Pierce™ Fluorescent Protease Assay Kit
Thermo Scientific™

Pierce™ Fluorescent Protease Assay Kit

Determine total protease activity in biological samples via fluorescent or colorimetric detection by measuring digestion of labeled casein substrate.

Have Questions?
카탈로그 번호수량
232662000 Test Kit
카탈로그 번호 23266
제품 가격(KRW)
395,000
Online offer
Ends: 31-Dec-2026
451,000
할인액 56,000 (12%)
Each
수량:
2000 Test Kit
대량 주문 또는 맞춤형 요청
제품 가격(KRW)
395,000
Online offer
Ends: 31-Dec-2026
451,000
할인액 56,000 (12%)
Each

The Thermo Scientific Pierce Fluorescent Protease Assay Kit measures total protease activity in samples, providing a means to assess the progress of protease isolation procedures or quantify protease contamination in biological samples.

This kit includes fluorescein-labeled casein as a substrate for assessing protease activity in a sample by either fluorescence resonance energy transfer (FRET) with a standard fluorometer or fluorescence polarization (FP) with capable instrumentation. FTC-Casein is native casein that has been labeled using a large molar excess of fluorescein isothiocyanate (FITC). Fluorescence properties of this heavily-labeled, intact protein substrate change dramatically upon digestion by proteases, resulting in a measurable indication of proteolysis.

Features of the Fluorescent Protease Assay Kit:

  • Casein substrate—measure activity of any protease that cleaves casein into peptide fragments
  • Trypsin standard—quantify protease activity relative to trypsin, a universally accepted reference
  • Sensitive—1000 times more sensitive than assays that use unmodified forms of casein
  • Simple and fast—test tube and microplate protocols are completed in less than one hour
  • Homogenous—addition steps only; no separation, transfer or stop steps required
  • Customizable—easily adapt time, temperature and pH to optimize sensitivity for proteases of interest

Applications:

  • Assess functional integrity and overall progress of protease purification
  • Quantify protease contamination in protein samples
  • Characterize the activity of unusual proteases compared to trypsin
  • Evaluate buffer conditions for their affects on protease function and activity

Additional Specifications:

  • Substrate: fluorescein-labeled casein (FITC-casein); available separately as Part No. 23267
  • Basis of assay: change in fluorescence resonance (FRET) or fluorescence polarization (FP)
  • Measurement: instrument with fluorescein excitation and emission filters (485/538nm)

Related Products

Pierce™ Colorimetric Protease Assay Kit (Cat. No. 23263)

FITC-Casein for Pierce™ Fluorescent Protease Assay Kit (Cat. No. 23267)

For Research Use Only. Not for use in diagnostic procedures.
사양
어세이Protease Assay
용도(애플리케이션)Protease Activity
용도(장비)Microplate Reader
제품라인Pierce
제품 유형Protein Activity Assay
수량2000 Test Kit
기질Casein
기질 특성Protein-Based Substrate
기질 유형Protease Substrate
충분2000 Microplate Assays
타겟Proteases
검출 방법Fluorescence
이뮤노어세이 키트 형식96-well Plate
라벨 유형Classic Dye
Unit SizeEach
구성 및 보관
Sufficient For: 2000 microplate assays using an instrument fitted with a fluorescein filter set (ex/em 485 nm/538 nm)
• FTC-Casein, lyophilized, 2.5 mg
• TPCK Trypsin Standard, 50 mg
• TBS Buffer Pack (makes 500 mL), 1 pack

Store FTC-Casein and TPCK Trypsin at 4°C.

자주 묻는 질문(FAQ)

In the Fluorescent Protease Assay Kit (Cat. No. 23266), I had poor reproducibility within my plate or across experiments. What could be the cause?

Variations in pipetting can directly contribute to assay error, especially in the FRET-mode, because the working reagent itself has some intrinsic background fluorescence. Use reverse-pipetting or other techniques to prevent the introduction of small air bubbles into the plate wells. In FP-mode, if the sample matrix contains very high amounts of interfering fluorescent material, better quality results may be obtained by subtraction of buffer blanks from the data used for the mP calculation. In addition, FP detection is very sensitive to the position of the optical head in relation to the center of the well with respect to its X and Y coordinates, especially with 384-well plates. This position-artifact may be identified as reproducible patterned data by positioning the plate for a second reading 180 degrees relative to the first reading. Ensure that the instrument read positioning settings are appropriate for the type of plate chosen.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

In the Fluorescent Protease Assay Kit (Cat. No. 23266), I saw no change in signal. What can I do?

Ensure that the instrument gain setting is sufficiently low to avoid saturating the instrument detector. For fluorescence readers containing multiple excitation/emission positions, ensure that “top/top” is selected for excitation/emission settings.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Do you offer any protein assays that are protein specific?

We offer several “specialty” protein assays including: Protease assay kits (Cat. Nos. 23263 and 23266), Glycoprotein Carbohydrate Estimation Kit (Cat. No. 23260), Phosphoprotein Phosphate Estimation Kit (Cat. No. 23270), Quantitative Peroxide assay kits (Cat. Nos. 23280 and 23285), and Easy-Titer Assay kits for IgG and IgM.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.