Pierce™ Reversible Protein Stain Kit for Nitrocellulose Membranes
Pierce™ Reversible Protein Stain Kit for Nitrocellulose Membranes
Thermo Scientific™

Pierce™ Reversible Protein Stain Kit for Nitrocellulose Membranes

The Pierce Reversible Protein Stain Kit for Nitrocellulose Membranes is a rapid and sensitive alternative to Ponceau S stain for자세히 알아보기
Have Questions?
카탈로그 번호수량
245801.5 L
카탈로그 번호 24580
제품 가격(KRW)
238,000
キャンペーン価格
Ends: 31-Dec-2025
280,000
할인액 42,000 (15%)
Each
카트에 추가하기
수량:
1.5 L
대량 주문 또는 맞춤형 요청
제품 가격(KRW)
238,000
キャンペーン価格
Ends: 31-Dec-2025
280,000
할인액 42,000 (15%)
Each
카트에 추가하기
The Pierce Reversible Protein Stain Kit for Nitrocellulose Membranes is a rapid and sensitive alternative to Ponceau S stain for protein detection on nitrocellulose membranes after transfer from polyacrylamide gels.

Features:
Sensitive—high-avidity, total-protein stain; lower limit of detection equals 25 to 50 ng per band
Specific—detects only protein; does not bind or interact with other electrophoresis or sample components
Protocol—stain in less than five minutes; completely erase and reverse staining in less than 15 minutes
Stability—components are stable at room temperature, saving refrigerator space and eliminating equilibration steps

Compare all membrane stains ›

This kit for membrane staining uses a nondestructive, reversible, reliable, and sensitive method to stain and detect proteins on nitrocellulose membranes. The lower limit of detection with this method is 25 to 50 ng per band (at least five times more sensitive than traditional Ponceau S staining). The stain has minimal nonspecific interactions with the membrane surface and protein-transfer reagents. The staining protocol is simple and quick and results in turquoise-blue bands that do not fade and are easily photographed for future reference. The stain can be easily reversed in less than 15 minutes. Subsequent western blot detection is unaffected because the stain does not alter the protein and is completely removed. In addition, the stain is compatible with N-terminal sequence analysis of proteins excised and eluted from membrane.
For Research Use Only. Not for use in diagnostic procedures.
사양
설명Pierce Reversible Protein Stain Kit for Nitrocellulose Membranes
검출 위치In-Blot Detection
검출 방법Colorimetric
제품라인Pierce
제품 유형Reversible Protein Stain Kit
수량1.5 L
타겟 분자Protein
라벨 또는 염료Proprietary Mix
Unit SizeEach
구성 및 보관
Sufficient For: 10 nitrocellulose membranes (8 cm x 8 cm) from mini gels (SDS-PAGE)
• Reversible Stain, 250 mL
• Destain, 2 x 500 mL
• Stain Eraser, 250 mL

Store at room temperature

자주 묻는 질문(FAQ)

How can I increase the signal intensity when I am using SuperSignal West Femto Maximum Sensitivity Substrate?

The following are possible causes for weak signal intensity:
- Low level of protein transferred from the gel to the membrane. This is particularly true for high molecular weight proteins. Reversible Protein Stain Kits for Nitrocellulose and PVDF membranes (Cat. Nos. 24580 and 24585, respectively) may be used to stain the bands on the membrane to indicate transfer efficiency.
- Over-diluted primary and secondary antibody probes. We suggest using the recommended dilution for the antibody probes for each substrate. More sensitive substrates will require a more dilute antibody solution.
- Short substrate incubation time. For best results, incubate the membrane for 5-15 min in the SuperSignal substrate.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

How can I increase the signal intensity when I am using SuperSignal West Dura Extended Duration Substrate?

The following are possible causes for weak signal intensity:
- Low level of protein transferred from the gel to the membrane. This is particularly true for high molecular weight proteins. Reversible Protein Stain Kits for Nitrocellulose and PVDF membranes (Cat. Nos. 24580 and 24585, respectively) may be used to stain the bands on the membrane to indicate transfer efficiency.
- Over-diluted primary and secondary antibody probes. We suggest using the recommended dilution for the antibody probes for each substrate. More sensitive substrates will require a more dilute antibody solution.
- Short substrate incubation time. For best results, incubate the membrane for 5-15 min in the SuperSignal substrate.

Find additional tips, troubleshooting help, and resources within our Protein Electrophoresis and Western Blotting Support Center.

인용 및 참조 문헌 (1)

인용 및 참조 문헌
Abstract
A high-affinity reversible protein stain for Western blots.
Authors:Antharavally BS, Carter B, Bell PA, Krishna Mallia A
Journal:Anal Biochem
PubMed ID:15158487
'We describe a reversible staining technique, using MemCode, a reversible protein stain by which proteins can be visualized on nitrocellulose and polyvinylidine fluoride (PVDF) membranes without being permanently fixed to the membrane itself. This allows subsequent immunoblot analysis of the proteins to be performed. The procedure is applicable only to ... More