384 Well Black Plate, Non-Treated Surface, Non-Sterile, Pack of 25
Thermo Scientific™

384 Well Black Plate, Non-Treated Surface, Non-Sterile, Pack of 25

Thermo Scientific™ Nunc™ black microplates are ideal for fluorescence measurements, with minimum back-scattered light and background fluorescence.
Have Questions?
카탈로그 번호수량
262260Case of 100
카탈로그 번호 262260
제품 가격(KRW)
-
수량:
Case of 100
Improve background, autofluorescence and crosstalk with Thermo Scientific™ Nunc™ 384-Well Polystyrene Black and White Microplates.
  • Black microplates are recommended for fluorescence measurements; with minimum back-scattered light and background fluorescence
  • White microplates are recommended for luminescence measurements; with maximum reflection and minimal autoluminescence
사양
인증/적합성All microplates manufactured by Nunc meet the recommendation of American National Standards (ANSI) (ANSI/SBS 1-2004)
배양 면적0.084 cm2/well
뚜껑Without Lid
케이스당 수100
팩당 수25
포장25/Pk., 100/Cs.
제품 유형Microplate
수량Case of 100
스커트 스타일Low Flange Pinchbar
부피(미터법) 작동10 to 100 μL
어레이16 x 24
색상Black
물질Polystyrene
웰 수384
제품라인Nunc
멸균Non-sterile
표면 처리Non-treated
부피(미터법) 웰120 μL
웰 형상Flat Bottom (F-well)
Unit SizeCase of 100

자주 묻는 질문(FAQ)

Do you offer Nunc Microplate Lids for the Nunc Black or White 384-Well Microplates?

We offer Nunc Microplate Lids: Cat. No. 448143, that fit both the 384-well microplates and the 1,536-well microplates.

Why do you offer Nunc 384-Well Black or White Microplates when the cells cannot be observed using an inverted light microscope?

We offer Nunc Black or White 384-Well microplates that are intended for use in conjunction with 384-well microplate luminometers and fluorometers that have excitation and detection systems located above the plate. Due to the opaque quality of these microplates, all detection systems must rely on either luminescent or fluorescent reagents, such as viability stains that report cell activity and membrane integrity.

Should I use an opaque black/white immuno plate, or an "optical-bottom" design?

Opaque plates can only be used on “top reader” instruments, which detect (or, in fluorescence mode, excite and detect) from above the plate. Readers that detect from underneath the plate (or imaging systems) use optical-bottom plates, which have a black or white upper well structure and a transparent (polystyrene film or optical coverglass) bottom.

Find additional tips, troubleshooting help, and resources within our Antibodies and Immunoassays Support Center.