384 Well White Plate, Non-Treated Surface, Non-Sterile, Pack of 25
Product Image
Thermo Scientific™

384 Well White Plate, Non-Treated Surface, Non-Sterile, Pack of 25

Color:White; Sterility:Non-sterile; Lid:Without Lid
Have Questions?
카탈로그 번호수량
262360100/Cs.
카탈로그 번호 262360
제품 가격(KRW)
1,135,000
Online offer
Ends: 31-Mar-2026
1,261,000
할인액 126,000 (10%)
Case of 100
카트에 추가하기
수량:
100/Cs.
제품 가격(KRW)
1,135,000
Online offer
Ends: 31-Mar-2026
1,261,000
할인액 126,000 (10%)
Case of 100
카트에 추가하기

Improve background, autofluorescence and crosstalk with Thermo Scientific™ Nunc 384-Well Polystyrene Black and White Microplates.

  • Black microplates are recommended for fluorescence measurements; with minimum back-scattered light and background fluorescence
  • White microplates are recommended for luminescence measurements; with maximum reflection and minimal autoluminescence
사양
인증/적합성All microplates manufactured by Nunc meet the recommendation of American National Standards (ANSI) (ANSI/SBS 1-2004)
배양 면적0.05 cm2
뚜껑Without Lid
케이스당 수100
팩당 수25
포장25/Pk., 100/Cs.
제품 유형Microplate
수량100/Cs.
부피(미터법) 작동10 to 100 μL
어레이16 x 24
색상White
물질Polystyrene
웰 수96
제품라인Nunc
멸균Non-sterile
표면 처리Non-treated
부피(미터법) 웰120 μL
웰 형상Flat Bottom (F-well)
Unit SizeCase of 100

자주 묻는 질문(FAQ)

Can I use Nunc White 384-Well Microplates for fluorescent assays?

Nunc White 384-Well Microplates can be used for fluorescent applications, but background fluorescence will be much higher compared to Nunc Black 384-Well Microplates.
We recommend the white microplates for scintillation and luminescent detection systems, in which the reflective properties of the microplate enhance the signal without producing any endogenous background signal.

Do you offer Nunc Microplate Lids for the Nunc Black or White 384-Well Microplates?

We offer Nunc Microplate Lids: Cat. No. 448143, that fit both the 384-well microplates and the 1,536-well microplates.

Why do you offer Nunc 384-Well Black or White Microplates when the cells cannot be observed using an inverted light microscope?

We offer Nunc Black or White 384-Well microplates that are intended for use in conjunction with 384-well microplate luminometers and fluorometers that have excitation and detection systems located above the plate. Due to the opaque quality of these microplates, all detection systems must rely on either luminescent or fluorescent reagents, such as viability stains that report cell activity and membrane integrity.

Should I use an opaque black/white immuno plate, or an "optical-bottom" design?

Opaque plates can only be used on “top reader” instruments, which detect (or, in fluorescence mode, excite and detect) from above the plate. Readers that detect from underneath the plate (or imaging systems) use optical-bottom plates, which have a black or white upper well structure and a transparent (polystyrene film or optical coverglass) bottom.