PageRuler™ Unstained High Range Protein Ladder
PageRuler™ Unstained High Range Protein Ladder
Thermo Scientific™

PageRuler™ Unstained High Range Protein Ladder

Thermo Scientific PageRuler Unstained High Range Protein Ladder is a mixture of eight (8) unstained proteins (60 to 250kDa) for자세히 알아보기
Have Questions?
카탈로그 번호수량
266372 x 250 μL
카탈로그 번호 26637
제품 가격(KRW)
443,000
Online offer
Ends: 31-Dec-2025
521,000
할인액 78,000 (15%)
Each
카트에 추가하기
수량:
2 x 250 μL
대량 주문 또는 맞춤형 요청
제품 가격(KRW)
443,000
Online offer
Ends: 31-Dec-2025
521,000
할인액 78,000 (15%)
Each
카트에 추가하기

Thermo Scientific PageRuler Unstained High Range Protein Ladder is a mixture of eight (8) unstained proteins (60 to 250kDa) for use as size standards in protein electrophoresis (SDS-PAGE) and Western blotting.

Features of PageRuler Unstained High Range Protein Ladder:

  • Size range—8 proteins spanning 60 to 250kDa
  • Ready-to-use—supplied in a loading buffer for direct loading on gels
  • Sharp bands—excellent accuracy for detection in with coomassie or silver stains
  • Reference band—150kDa band has greater intensity for easy orientation
  • Tagged—each protein in the ladder contains an integral Strep-tag™ II Sequence
  • Quality tested—each lot evaluated by SDS-PAGE and Western blotting

The protein MW markers in this ladder resolve into clearly identifiable sharp bands when analyzed by SDS-PAGE and stained with coomassie dye or silver. The 150kDa band is of greater intensity and serves as a reference band. Proteins can be detected on Western blots by staining with Ponceau S, coomassie blue or other protein stains. In addition, the ladder proteins contain an integral Step-tag™ II Sequence and may be detected on Western blots using Strep-Tactin™ Conjugates. The PageRuler Unstained High Range Protein Ladder is supplied ready-to-use: no heating, dilution or addition of a reducing agent is required before use.

Includes:

  • Proteins (0.02 to 0.05 mg/mL of each) in 62.5 mM Tris-H3PO4 (pH 7.5 at 25°C), 1 mM EDTA, 2% SDS, 100 mM DTT, 1 mM NaN3, 0.01% bromophenol blue and 33% glycerol

Applications:

  • Accurate protein sizing on SDS-polyacrylamide gels and Western blots.
For Research Use Only. Not for use in diagnostic procedures.
사양
용도(애플리케이션)Tris-acetate gels
젤 호환성Bolt™ Bis-Tris Plus Gels, Novex™ Tricine Gels, Novex™ Tris-Glycine Gels, NuPAGE™ Bis-Tris Gels, NuPAGE™ Tris-Acetate Gels, SDS-PAGE Gels
분자량250, 200, 150, 120, 100, 85, 70, 60 kDa
제품라인PageRuler
제품 유형Protein Ladder
수량2 x 250 μL
로드 준비Yes
권장 애플리케이션Tris-acetate gels
배송 조건Approved for shipment on Wet or Dry Ice
염색 유형Unstained
시스템 유형Western Blotting, SDS-PAGE
Number of Markers8
크기 범위60 to 250 kDa
Unit SizeEach
구성 및 보관
Upon receipt store at -20°C. Product is shipped with an ice pack.

자주 묻는 질문(FAQ)

The upper bands of the ladder are missing. What could be the reason?

The upper bands of the ladder may be degraded by proteases. Ladder, gel, buffer, pipettes, pipette tips, or equipment can be contaminated by proteases during usage. A general recommendation would be to avoid working with proteases in the same room. We would recommend preparing fresh solutions, cleaning the equipment, and using clean pipettes and tips. If the ladder itself is contaminated, please use a new tube of the ladder.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Some additional bands or smears were observed on the gel when using a PageRuler unstained ladder. What may have caused this?

Additional bands can appear due to dithiothreitol (DTT) oxidation in the storage buffer. Please add newly prepared DTT solution to the final concentration of 100 mM and boil for 5 min at 95 degrees C. This should solve the issue. Addition of DTT is NOT recommended for prestained protein ladders, since too high a concentration of reducing agents can cause protein destaining.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Do the proteins in Thermo Scientific protein ladders have a His-Tag or would otherwise react with an anti-His-Tag antibody?

No, proteins in Thermo Scientific protein ladders are not His tagged. However, non-specific interaction between the ladder proteins and primary or secondary antibodies is possible and some His-Tag detection systems, such as Thermo Scientific 6xHis Protein Tag Stain Reagent Kit, show non-specific interaction. The protein ladder bands are more readily detected when using high antibody concentrations. The non-specific cross-reactivity is difficult to predict, it often has a different pattern dependent on the antibodies used in each individual experiment. The most general way to handle this problem would be to use lower concentrations of antibodies and to use lower amount of protein ladders. It may also be useful to leave one empty well between the ladder and the sample to overcome a possible leakage of the signal to the nearby sample lane.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Can Thermo Scientific protein ladders be detected by Strep-Tactin conjugates?

PageRuler Unstained protein ladders can be detected directly on Western blots by using Strep-Tactin conjugates or an antibody against the Strep-tag II sequence. All PageRuler and Spectra ladder proteins contain an integral Strep-tag II sequence, however the prestained ladders cannot be detected by Strep-Tactin conjugates.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Why is non-specific binding detected after Western blot?

Protein ladder bands can sometimes be detected with chemiluminescent techniques due to non-specific interactions of ladder proteins with either primary or secondary antibodies (or with both). The ladder bands are only rarely detected by chromogenic substrates. The extremely high sensitivity of the chemiluminescent assays is needed to see the bands, so the actual degree of cross-reactivity is low. The non-specific cross-reactivity is difficult to predict, it often has a different pattern depending on the antibodies used. If antibodies recognize a linear epitope, the cross-reactivity may be due to sequence homology. If antibodies react with a denaturation-resistant conformational epitope it could be impossible to identify the exact reason for detected cross-reactivity. The most general way to handle this problem would be to use lower concentrations of antibodies.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.