Plate and Module with Affinity Binding Surface
Plate and Module with Affinity Binding Surface
Thermo Scientific™

Plate and Module with Affinity Binding Surface

Thermo Scientific™ Plate and Module with Affinity Binding Surface로 분자 배향의 변동성을 줄이십시오.
Have Questions?
보기 방식 변경buttonViewtableView
카탈로그 번호색상제품 유형표면 처리전체 부피(미터법) 웰
436033WhiteMicroplateGlutathione400 μL
436014ClearMicroplateStreptavidin400 μL
436015WhiteMicroplateStreptavidin400 μL
436016BlackMicroplateStreptavidin400 μL
436017ClearMicroplateStreptavidin120 μL
436020ClearSolid Module F8 (x12) in FrameStreptavidin400 μL
436022ClearLock-Well Module C8 (x12) in FrameStreptavidin350 μL
95029263ClearMicroplateStreptavidin400 μL
95029293ClearBreakable Module F8 (x12) in FrameStreptavidin400 μL
카탈로그 번호 436033
제품 가격(KRW)
-
색상:
White
제품 유형:
Microplate
표면 처리:
Glutathione
전체 부피(미터법) 웰:
400 μL
Thermo Scientific™ Plate and Module with Affinity Binding Surface로 분자 배향의 변동성을 줄이십시오.

친화도 포획 표면(패시브 스트렙타아비딘 및 임모빌라이저 스트렙타아비딘, 니켈 킬레이트 및 글루타티온, 바이오밴드):

  • 특이도가 높은 결합 표면이 분자 배향의 변동성을 줄입니다.
  • 임모빌라이저 표면이 신호 대 잡음비를 개선합니다.
  • 스트렙타아비딘 바이오틴 상호 작용을 활용하여 광범위한 생체 분자를 부동태화시킬 수 있습니다.
  • 책임 보증 기간: 판매 약관에 제시된 모든 보증 요건 및 배제 조항에 따라 달라질 수 있으나 이 제품의 보증 기간은 제품을 선적한 날짜부터 이후 구십(90)일입니다.

    내부 연구 목적 사용 제한에 대한 면책 사항: 내부 연구 목적만을 위해 제품을 이용하는 구매자에 대한 어떠한 제한 사항도 이 문구와 관련된 웹 페이지의 제품에 적용되지 않습니다.

    사양
    결합 유형Affinity
    검출 방법Chemiluminescence
    케이스당 수15
    팩당 수1
    포장15 Cases
    플레이트 블로킹Unspecified
    제품 유형Microplate
    타겟 분자GST
    전체 부피(미터법) 웰400 μL
    부피(미터법) 작동100 μL
    어레이8 x 12
    색상White
    형식Standard
    물질Polystyrene
    웰 수96
    멸균Non-sterile
    표면 처리Glutathione
    부피(미터법) 웰400 μL
    웰 형상Flat Bottom (F-well)
    Unit SizeCase of 15

    자주 묻는 질문(FAQ)

    What is the detection limit of proteins with Immobilizer Glutathione plates?

    The background is extremely low when using the Immobilizer Glutathione plates. This results in a high signal-to-noise ratio and a low detection limit which in general means that the detection limit (OD 0.5) is 3 ng per well (100 µL).

    How long are Immobilizer Glutathione plates stable?

    The Immobilizer Glutathione plates are extremely stable over long periods of time, if stored at room temperature (20-25 degrees C). We guarantee 12 mths of shelf life in unopened foil package after the date of shipment.

    With Immobilizer Glutathione plates, why should I use Tween-20 surfactant in the washing step and in the buffers containing the antibodies?

    We recommend using 0.05% Tween-20 surfactant (as the non-ionic detergent) to improve the signal-to-noise ratio of the assay and thus decrease the background.

    Should I optimize the concentration of the purified GST or GST-tagged protein to be used with Immobilizer Glutathione plates?

    Yes. We recommend using a solution of the purified GST or GST-tagged protein diluted in Phosphate Buffered Saline (PBS), pH 7.2 in a concentration ranging from 0.01-1 µg/mL. During the coupling, non-ionic detergents like Tween-20 surfactant should not be present, as these will suppress the coupling.

    Which type of molecules can I use with Immobilizer Glutathione plates?

    The Immobilizer Glutathione plates are designed for optimal detection of glutathione-S-transferase (GST)-tagged proteins or purified GST.