Immuno Standard Module White and Black
Immuno Standard Module White and Black
Immuno Standard Module White and Black
Immuno Standard Module White and Black
Immuno Standard Module White and Black
Immuno Standard Module White and Black
Immuno Standard Module White and Black
Thermo Scientific™

Immuno Standard Module White and Black

Thermo Scientific™ Immuno Standard Module White and Black을 사용해 형광/발광 면역 분석법 및 결합 분석법을 수행할 수 있습니다.
Have Questions?
보기 방식 변경buttonViewtableView
카탈로그 번호색상부피(미터법) 웰표면 처리
437702White350 μLPolySorp
437591White350 μLMaxiSorp
437915Clear350 μLMaxiSorp
475515Black400 μLMaxiSorp
475523Black400 μLPolySorp
7566White380 μLHydrophobic
카탈로그 번호 437702
제품 가격(KRW)
1,061,000
Case of 60
카트에 추가하기
색상:
White
부피(미터법) 웰:
350 μL
표면 처리:
PolySorp
제품 가격(KRW)
1,061,000
Case of 60
카트에 추가하기
Thermo Scientific™ Immuno Standard Module White and Black을 사용해 형광/발광 면역 분석법 및 결합 분석법을 수행할 수 있습니다.
특징:
  • 8웰, 12웰 또는 16웰 스트립으로 제공
  • 최적의 분석을 위해 프레임이 있거나 없는 형태 선택
  • 편평 바닥 또는 C형 웰
  • 최적의 결합을 위한 세 가지 표면 옵션
  • 낮은 배경 형광으로 가능한 높은 신호 반사를 제공하는 흰색 형식(형광 관찰에 권장)
  • 형광 관찰 시 발생할 수 있는 후방 산란광을 줄이는 검정색 형식
  • 시간 분해 형광 분야에서만 사용되는 투명 형식
  • 표면 옵션:

  • Thermo Scientific™ PolySorp™ 및 Microlite™ 1+는 소수성 분자를 흡착하는 데 사용됩니다.
  • Microlite 2+는 약간의 친수성을 가지며 다양한 생체 분자와 결합합니다.
  • Thermo Scientific™ MaxiSorp™는 친수성이며 항체 샌드위치 분석에 이상적입니다.

  • 책임 보증 기간: 판매 약관에 제시된 모든 보증 요건 및 배제 조항에 따라 달라질 수 있으나 이 제품의 보증 기간은 제품을 선적한 날짜부터 이후 구십(90)일입니다.

    내부 연구 목적 사용 제한에 대한 면책 사항: 내부 연구 목적만을 위해 제품을 이용하는 구매자에 대한 어떠한 제한 사항도 이 문구와 관련된 웹 페이지의 제품에 적용되지 않습니다.

    사양
    결합 특성Hydrophobic
    분리No
    인증No
    검출 방법Chemiluminescence
    용도(애플리케이션)Fluorescence and Luminescence
    케이스당 수60
    팩당 수5
    포장60 Cases
    플레이트 블로킹None
    제품 유형Microplate Strip
    수량60/Cs.
    타겟 분자Lipids
    부피(미터법) 작동250 μL
    어레이8 x 12
    색상White
    형식Standard
    물질Polystyrene
    웰 수96
    멸균Non-sterile
    표면 처리PolySorp
    부피(미터법) 웰350 μL
    웰 형상Round, C Bottom
    Unit SizeCase of 60

    자주 묻는 질문(FAQ)

    For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

    The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
    - Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
    - Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
    - "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
    - StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

    Which surfaces do you recommend for RIA (radioimmunoassay)?

    The choice of plates or modules will depend on the type of RIA you are planning to perform and specific assay conditions. Nunc provides two different surfaces for immunoassays, PolySorp and MaxiSorp.
    - MaxiSorp surface is highly charged and should be used if the assay requires quantitative measurement of proteins (antibodies) or molecules with polar groups.
    - PolySorp surface should be used if the assay consists of less polar molecules with hydrophobic characteristics.

    Which 96-well Immuno plates or modules do you recommend for various applications?

    The following list offers a brief description of the features of Nunc products and their specific applications:
    - Nunc-Immuno Plates, MaxiSorp surface - These plates are designed for solid phase immuno assays and have a polystyrene surface with high affinity for polar groups and hydrophilic molecules. These 96-well plates are available with flat (F), round (U), or (C) bottom-well designs.
    - Nunc-Immuno Plates, PolySorp surface - These plates have a polystyrene surface which adsorps less polar molecules compared to the MaxiSorp surface and has a high affinity for hydrophobic groups. These 96-well plates are available with flat (F), round (U), or (C) bottom-well designs.
    - Nunc-Immuno Modules - These modules are designed for solid-phase immuno assays. The modules are available in 8-, 12- or 16-well formats with (F), (U), and (C) bottom-well and 8-well BreakApart with (C) bottom-well designs. These different formats allow one to choose the style which is appropriate for their assay design.
    BreakApart Modules and LockWell Modules can be used for radioimmunoassays.
    - Nunc StarWell Immuno Breakable Modules - The 8-well modules feature eight fins on the inner wall of the (C) bottom wells. This design increases the surface area by 50%. The increase in surface area allows more molecules to be immobilized, increasing assay signal. The fin configuration provides shorter diffusion distance to the surface, reducing incubation times.
    - LockWell Immuno Breakable Modules - Each plate consists of 1 x 8 breakable strips. These strips are assembled in a designed frame which locks each well into place by a spring lock. This spring lock design orientates each well at the same horizontal level allowing uniform washing and reading. The LockWell Modules are available with round (U), (C) or StarWell bottom-well designs.
    - Plates and Modules with (CovaLink) Covalent Binding Surfaces: These plates can be used to bind proteins, peptides, DNA or carbohydrates. Covalent linkage occurs via secondary amine group. This allows a specific orientation and provides improved stability compared to passive adsorption due to chemical binding between molecules. Binding of molecules on PolySorp and MaxiSorp surfaces is obtained by passive adsorption. CovaLink is a surface grafted with secondary amino groups (<NH) which serves as a bridge for covalent coupling. The covalent binding can immobilize small molecules such as biotin or peptides which may otherwise bind weakly by physical adsorption and facilitate the recognition by detection molecule.
    - Nunc FluoroNunc/LumiNunc 96-Well Plates: These plates are optimized for IFMA (Immunofluorometric Assays) or FIA (Fluorometric Immuno Assays). The transparent polystyrene plates give a low background fluorescence and are optimal where a read-through system is used. The white plates/modules provide maximum reflection of fluorescence signal while maintaining low background. The white plates/modules are often used for epifluorescence reading. Black modules reduce background fluorescence and minimize back-scatter light which is often encountered in epifluorescence.

    What is the maximum binding capacity for proteins on the Thermo Scientific MaxiSorp surface and PolySorp surface?

    Molecules bind to our PolySorp and MaxiSorp surfaces through passive adsorption.
    Using IgG as a reference molecule and knowing that it is a globular molecule, theoretical calculations indicate that the maximum binding for proteins are:
    - For the MaxiSorp surface, in monolayer: 650 ng/cm^2
    - For the PolySorp surface: 220 ng/cm^2.

    What is the difference between your Thermo Scientific PolySorp, MaxiSorp, and MiniSorp surfaces?

    MaxiSorp, PolySorp and MiniSorp surfaces were developed for immunology assays:
    - The MaxiSorp surface is a modified, highly charged polystyrene surface with high affinity for molecules with polar or hydrophilic groups. The surface has a high binding capacity for proteins, including globular antibodies in proper orientation. Thus, it offers very high sensitivity in double antibody "sandwich" tests.
    - The PolySorp surface is more hydrophobic than the MaxiSorp surface. It has high affinity to molecules of a more hydrophobic character. This surface is particularly suited to non-protein antigens including virus antigens.
    - The MiniSorp surface is a polyethylene surface with very low affinity to molecules of any type. This type of surface is ideal for the liquid phase immuno techniques.
    - The MiniSorp surface is only available in a tube format, while the MaxiSorp and PolySorp surfaces are offered in both 96-well plate and module formats.