카탈로그 번호표면 처리인증부피(미터법) 작동바코드
439454MaxiSorpYes350 μLNo Barcode
3355Immulon 1 BNo230 μLNo Barcode
3455Immulon 2 HBNo280 μLNo Barcode
3855Immulon 4 HBXNo280 μLNo Barcode
442404MaxiSorpNo350 μLNo Barcode
456529PolySorpNo350 μLNo Barcode
456537MaxiSorpYes350 μLNo Barcode
460984MaxiSorpYes350 μLIncludes Barcode
467320MediSorpYes350 μLNo Barcode
467340MultiSorpNo350 μLNo Barcode
475094PolySorpNo350 μLNo Barcode
9502227Universal BindingNo330 μLNo Barcode
95029330Enhanced BindingYes330 μLNo Barcode
카탈로그 번호 439454
제품 가격(KRW)
164,000
온라인 행사
Ends: 31-Dec-2025
199,000
할인액 35,000 (18%)
Case of 60
카트에 추가하기
표면 처리:
MaxiSorp
인증:
Yes
부피(미터법) 작동:
350 μL
바코드:
No Barcode
제품 가격(KRW)
164,000
온라인 행사
Ends: 31-Dec-2025
199,000
할인액 35,000 (18%)
Case of 60
카트에 추가하기
정량 및 정성 solid phase immunoassay에 이상적인 Thermo Scientific™ Nunc™, Immulon™ 및 Microtiter™ 투명 플레이트를 특징으로 하는 Thermo Scientific™ Clear Flat-Bottom Immuno Nonsterile 96-Well Plate는 colormetric assays에서 신뢰할 수 있고 재현성있는 결과를 보여주며, 네 가지 결합 표면 옵션으로 제공됩니다.

96-웰 솔리드 플레이트:

  • 투명 폴리스티렌
  • 최적의 결합을 위한 네 가지 표면 옵션
  • 행과 열에 알파벳과 숫자로 라벨링됨

표면:

  • Thermo Scientific™ PolySorp™, Immulon™ 1B, Universal Binding(UB)은 소수성 분자를 흡착하는 데 사용됩니다.
  • Thermo Scientific™ Medisorp™ 및 Immulon 2HB는 약한 친수성이고 다양한 생물 분자를 결합합니다.
  • Thermo Scientific™ MaxiSorp™, Immulon 4 HBX, Enhanced Binding(EB)는 친수성이고 항체 샌드위치 어세이에 이상적입니다.
  • Thermo Scientific™ MultiSorp™는 친수성이 매우 강하며 글리칸과 수용성 단백질에 이상적입니다.

주문 정보:

국가별로 제공 여부가 달라질 수 있습니다. 467320, 456537, 460984 및 439454에는 인증서가 포함됩니다.

보증: 90일

내부 연구 목적 사용 제한에 대한 면책 사항: 내부 연구 목적만을 위해 제품을 이용하는 구매자에 대한 어떠한 제한 사항도 이 문구와 관련된 웹 페이지의 제품에 적용되지 않습니다.
사양
결합 특성Hydrophilic
인증Yes
검출 방법Colorimetric
뚜껑Without Lid
케이스당 수60
팩당 수5
포장12 inner bags of 5 each
플레이트 블로킹None
제품 유형Microplate
수량60/Cs.
스커트 스타일Pinchbar
타겟 분자Antibodies (Glycoproteins)
부피(미터법) 작동350 μL
웰 디자인F96
어레이8 x 12
바코드No Barcode
색상Clear
형식Standard
물질Polystyrene
웰 수96
멸균Non-sterile
표면 처리MaxiSorp
부피(미터법) 웰400 μL
웰 형상Flat Bottom (F-well)
Unit SizeCase of 60

자주 묻는 질문(FAQ)

What is a good alternative to Clear Flat-Bottom Immuno Nonsterile 96-Well Plates, MaxiSorp, 350 µL (Cat. No. 439454)?

There is no exact alternative. The closest alternative can be found on the same product page, Cat. No. 442404. Two other potential alternatives on the same product page are Cat. No. 456537 and Cat. No. 460894. You can view the specific differences between these products on the product page by clicking into the "Full Specifications" dropdown for each.

For Clear Flat-Bottom Immuno Nonsterile 96-Well Plates, is the surface treatment solely on the bottom of the well, or is it also applied to the sides?

For energy treated plates, the entire plate surface receives the energy treatment. The MaxiSorp, PolySorp, MediSorp and MultiSorp plates are energy treated plates. For traditionally treated plates, the well surface is treated up to the listed working volume.

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.