Megaplex™ Primer Pools, Rodent Pools B v3.0
Product Image
Applied Biosystems™

Megaplex™ Primer Pools, Rodent Pools B v3.0

Megaplex™ Primer Pools, Rodent Pool B v3.0 is available under a single part number containing both the Megaplex™ RT Primers자세히 알아보기
Have Questions?
카탈로그 번호수량
444475250 reactions
카탈로그 번호 4444752
제품 가격(KRW)
2,265,000
Each
카트에 추가하기
수량:
50 reactions
제품 가격(KRW)
2,265,000
Each
카트에 추가하기
Megaplex™ Primer Pools, Rodent Pool B v3.0 is available under a single part number containing both the Megaplex™ RT Primers and Megaplex™ PreAmp Primers, Rodent Pools B v3.0. Megaplex™ RT Primers, Rodent Pool B contains RT primers for 306 and 135 unique microRNAs for mouse and rat respectively plus 4 species specific controls. For use when assay sensitivity is of the utmost importance, Megaplex™ PreAmp Primers significantly enhance the ability to detect low expressed microRNAs enabling the generation of a comprehensive expression profile using far less sample, as low as 1 ng of input total RNA. The microRNA targets represented in this pool tend be less well characterized, more narrowly expressed and⁄or expressed at a lower level compared to Rodent Pool A. Rodent Pool B is intended for use with the TaqMan Rodent MicroRNA B Array v3.0, however, it can also be used to prepare cDNA for real-time analysis using the individual TaqMan® MicroRNA Assays.
For Research Use Only. Not for use in diagnostic procedures.
사양
반응 수50 Reactions
프라이머RT Primers, PreAmp Primers
제품라인Megaplex, TaqMan
제품 유형Primer Pool
수량50 reactions
Rat, Mouse
충분50 Reactions
용도(애플리케이션)miRNA analysis
GC-Rich PCR PerformanceLow
PCR 방법qPCR
Unit SizeEach
구성 및 보관
Store at -20°C.

자주 묻는 질문(FAQ)

Can Ct's greater than a cut-off be considered valid results?

Yes they can. However, it is important to recognize the true linearity and detection limits of your assay: Ct values above the cut-off can indicate non-specific amplification, unless your NTC is a true- no-target control, and you have run a statistically significant number of replicates. Any results with Ct above the recommended cut-off need to be validated with individual assays on plates.

What is a good Ct cut-off for the TaqMan MicroRNA Array Cards and TaqMan Advanced miRNA Array Cards? In other words, beyond what Ct should I not trust the data?

The typical Ct cut-off on TaqMan Array Cards is 32, which is equivalent to Ct 35 on a plate (10 µl reaction). Previous studies show that if you use pre-amplification, a Ct cut-off of 29 or 30 can be used to reduce numbers of false positives (see Technical Note Optimized protocols for human or rodent microRNA profiling with precious samples). To ensure that you have selected a correct cut-off, you should run replicates of the same sample and use Ct cut-off before you see an increase in the Standard Deviation.