Veriti™ Dx 96-well Thermal Cycler, 0.2 mL
Veriti™ Dx 96-well Thermal Cycler, 0.2 mL
Applied Biosystems™

Veriti™ Dx 96-well Thermal Cycler, 0.2 mL

The Veriti™ Dx 96-Well Thermal Cycler delivers the proven reliability you expect from Applied Biosystems for in vitro diagnostic PCR자세히 알아보기
Have Questions?
카탈로그 번호수량
44523001 instrument
카탈로그 번호 4452300
제품 가격(KRW)
-
수량:
1 instrument
The Veriti™ Dx 96-Well Thermal Cycler delivers the proven reliability you expect from Applied Biosystems for in vitro diagnostic PCR use. It features an easy-to-use color touch screen to simplify setup and use of the system, and VeriFlex™ Blocks, six independent temperature blocks designed to give precise control over your PCR optimization. Optional setups for fast PCR or standard PCR methods provide flexibility to shorten your PCR cycling time.

• Classified as US FDA Class I Medical Device for in vitro diagnostic use
• Conforms to IVDD (98⁄79⁄EC) requirements and labeled in Europe with a CE IVD mark
• Manufactured to ISO 13485 and GMP requirements
• Features an easy-to-use graphical interface (6.5 inch VGA touch screen)
• Innovative VeriFlex™ Blocks provide convenient PCR optimization
• Standard and fast-enabled cycling to address your current and future PCR needs
• Reduced PCR reaction time when using faster ramp rates
Classified as US FDA Class I Medical Device for in vitro diagnostic use. Conforms to IVDD (98/79/EC) requirements.
사양
치수19.1 x 9.3 x 9.6 in. (48.5 x 23.7 x 24.5 cm)
디스플레이 유형6.5 in. VGA 32 k Color Touchscreen
용도(장비)Veriti Dx Thermal Cycler
최대 램프 속도3.9°C/sec. (Block), 3.35°C/sec. (Sample)
수량1 instrument
반응 속도Fast, Standard
열 정확도±0.25°C (35°C to 99.9°C)
열 범위0°C to 100°C
열 균일성<0.5°C (20 sec. after reaching 95°C)
사용자 인터페이스USB, Wi-Fi, Ethernet
전압100/240 V
워런티Limited Warranty
무게25 lb. (11.4 kg)
블럭 구성96-well, 6-Zone VeriFlex Block
블록 형식Non-interchangeable
용량96-well, 0.2 mL
프로그램 수>500
제품 유형Thermal Cycler
Unit SizeEach
구성 및 보관
Store at room temperature.

자주 묻는 질문(FAQ)

Which thermal cyclers have been tested for use with Cytoscan HD?

We recommend using the following thermal cyclers with Cytoscan HD:

For pre-PCR, we recommend 2720 Thermal Cycler (Cat. No. 4359659)

For pre- and post-PCR , we recommend the following thermal cyclers:
- GeneAmp PCR System 9700 Gold (Cat. No. 4314878) (Note: This instrument has been discontinued and therefore cannot be ordered)
- GeneAmp PCR System 9700 Silver (Cat. No. N8050001) (Note: This instrument has been discontinued and therefore cannot be ordered)
- Applied Biosystems Veriti Dx 96-Well Thermal Cycler (Cat. No. 4452300)
- Applied Biosystems Veriti 96-Well Thermal Cycler (Cat. No. 4375786)
- Bio-Rad® DNA Engine® PTC-200 Thermal Cycler
- Eppendorf® Mastercycler® Pro S Thermal Cycler


Note: You must use thermal cyclers with silver or gold-plated silver blocks. Do not use thermal cyclers with aluminum blocks.

Find additional tips, troubleshooting help, and resources within our Microarray Analysis Support Center.

What is the optimal ramp rate for my thermal cycler?

There is no universal ramp rate for a thermal cycler because both the block and sample ramp rates are different for each thermal cycler. The sample ramp rate changes with the volume of the sample since more time and energy are required to heat higher sample volumes. The ramp rate may also need to be changed for a particular PCR assay or primer pair if you are trying to use the same PCR assay on two different thermal cyclers, for example.

As a reference, the block ramp rate commonly used with DreamTaq Polymerase on the MiniAmp thermal cycler is 3.0 C/sec. In a 50 µL PCR reaction, this translates to a sample ramp rate of ~1 C/sec.

Please refer to the following application note for further information about thermocycler ramp rates: https://assets.thermofisher.com/TFS-Assets/LSG/brochures/Thermal_Cycler_Ramp_RatesAppNote.pdf

Find additional tips, troubleshooting help, and resources within ourPCR Thermal Cyclers Support Center.