Thermo Scientific™

Immuno Clear Standard Module

Immuno Clear Standard Modules을 사용하여 웰과 웰간의 재현성을 보여주는 작업을 수행하십시오. 표준 장비와 호환되도록 제조되었습니다.
Have Questions?
보기 방식 변경buttonViewtableView
카탈로그 번호표면 처리부피(미터법) 작동웰 형상웰 디자인
468667MaxiSorp350 μLRound, Flat Bottom (F-well)F8
434797MaxiSorp350 μLRound, Flat Bottom (F-well)F8
441653MaxiSorp250 μLRound, C BottomC8
444865PolySorp250 μLRound, C BottomC8
445101MaxiSorp250 μLRound, C BottomC8
467120MediSorp350 μLRound, Flat Bottom (F-well)F8
467140MultiSorp350 μLRound, Flat Bottom (F-well)F8
467466MaxiSorp350 μLRound, Flat Bottom (F-well)F16 (2x8 wells)
467679PolySorp350 μLRound, Flat Bottom (F-well)F16
469078PolySorp350 μLRound, Flat Bottom (F-well)F8
469264Hydrophilic250 μLRoundU16
469914MaxiSorp350 μLRound, Flat Bottom (F-well)F16 (2x8 wells)
469922PolySorp350 μLRound, Flat Bottom (F-well)F16 (2x8 wells)
469949MaxiSorp350 μLRound, Flat Bottom (F-well)F8
469957PolySorp350 μLRound, Flat Bottom (F-well)F8
473709MaxiSorp250 μLRound, C BottomC12
475078MaxiSorp250 μLRoundU8
475086PolySorp250 μLRoundU8
6302Immulon 2 HB330 μLRound, Flat Bottom (F-well)F12
6309Immulon 2 HB330 μLRound, Flat Bottom (F-well)F12
6310Immulon 1 B330 μLRound, Flat Bottom (F-well)F12
6405Immulon 4 HBX330 μLRound, Flat Bottom (F-well)F12
95029100Enhanced Binding350 μLRound, Flat Bottom (F-well)F8
6301TS1
6301으로도 사용됨
Immulon 1 B330 μLRound, Flat Bottom (F-well)F12
카탈로그 번호 468667
제품 가격(KRW)
314,500
온라인 행사
Ends: 31-Dec-2025
382,000
할인액 67,500 (18%)
Case of 60
카트에 추가하기
표면 처리:
MaxiSorp
부피(미터법) 작동:
350 μL
웰 형상:
Round, Flat Bottom (F-well)
웰 디자인:
F8
제품 가격(KRW)
314,500
온라인 행사
Ends: 31-Dec-2025
382,000
할인액 67,500 (18%)
Case of 60
카트에 추가하기

ELISA 기술용으로 개발된 Nunc™, Immulon™ 및 Microtiter™ 모듈 플레이트를 채택한 Thermo Scientific™ Immuno Clear Standard Module을 이용하여 웰과 웰 사이의 재현성을 보여주는 작업을 수행하십시오. 표준 장비와 함께 사용할 수 있도록 제조된 이 모듈은 작은 샘플 사이즈 사용으로 구성 요소들의 유연한 사용이 가능합니다. 업계 최고의 품질 기준과 인증이 뒷받침됩니다.

특징:

  • 여러 가지 스트립(strip) 형태: 8웰 스트립, 12웰 스트립, 16웰 스트립(8웰 컬럼 두 개)
  • 여러 가지 웰 모양: 평평한 바닥, C 바닥(반경 엣지), U자 웰, 스타웰(웰에 표면적을 넓히고 작업 성능을 향상시키는 핀이 있음)
  • 분석 성능을 극대화하는 여러 가지 표면
  • 뒤집었을 경우에도 프레임 내에 유지되는 모듈
  • 뚜껑 방향을 위한 표시가 있으며 적재 가능한 프레임
  • 폴리에틸렌 프레임에 폴리스티렌 웰
  • 확장 치수: 128 × 86mm

표면 옵션:

  • Thermo Scientific™ PolySorp™, Immulon™ 1B, Universal Binding(UB)은 소수성 분자를 흡착하는 데 사용됩니다.
  • Thermo Scientific™ Medisorp™ 및 Immulon 2HB는 약한 친수성이고 다양한 생물 분자를 결합합니다.
  • Thermo Scientific™ MaxiSorp™, Immulon 4 HBX, Enhanced Binding(EB)는 친수성이고 항체 샌드위치 어세이에 이상적입니다.
  • Thermo Scientific™ MultiSorp™는 친수성이 매우 강하며 글리칸과 수용성 단백질에 이상적입니다.

주문 정보:

모듈은 자체적으로 세워집니다. 카탈로그 번호 95029440 및 464394는 인증을 획득했습니다. 프레임과 모듈을 따로 사용 가능합니다. 밀봉 테이프 및 스트립 캡 사용이 가능합니다. 요청 시에는 색상 코딩된(color-coded) 모듈 사용이 가능합니다. 자세한 정보는 고객 서비스 부서 또는 영업 담당자에게 문의하십시오.

보증: 90일

내부 연구 목적 사용 제한에 대한 면책 사항: 내부 연구 목적만을 위해 제품을 이용하는 구매자에 대한 어떠한 제한 사항도 이 문구와 관련된 웹 페이지의 제품에 적용되지 않습니다.
사양
결합 특성Hydrophilic
인증/적합성Certified for adsorption of IgG; CV of <5% between wells
인증Yes
검출 방법Colorimetric
뚜껑Without Lid
케이스당 수60
팩당 수ROC 5, ROS 10
포장12 inner bags of 5 each
플레이트 블로킹None
제품 유형Strip Plate
수량60/Cs.
타겟 분자Antibodies (Glycoproteins)
부피(미터법) 작동350 μL
웰 디자인F8
어레이8 x 12
색상Clear
형식Strip Plate
물질Polystyrene
웰 수96
멸균Non-sterile
표면 처리MaxiSorp
부피(미터법) 웰400 μL
웰 형상Round, Flat Bottom (F-well)
Unit SizeCase of 60

자주 묻는 질문(FAQ)

What frames do you recommend for your Immuno Clear Standard Modules?

We recommend Frames and Accessories for Immuno Breakable Modules, BreakApart frame (Cat. No. 465404). This frame is designed to hold the Immuno Clear Standard Modules.

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

What is the difference between certified and non-certified MaxiSorp plates and modules?

Both of these surfaces are identical. The only difference between them is that for the certified plates, a representative sample from each manufacturing lot undergoes a Binding Capacity test. This test is an ELISA-like assay used in our quality control laboratories to ensure binding capabilities.