Choose from four surfaces and a variety of wells and configurations with these immuno breakable modules, which offer an optimal choice of products for the specific assay.
Have Questions?
보기 방식 변경buttonViewtableView
카탈로그 번호표면 처리웰 형상팩당 수제품 유형
473768MaxiSorpRound, C Bottom5Strip Plate
446442PolySorpRound, C Bottom5Strip Plate
446469MaxiSorpRound, C Bottom10Strip Plate
446477PolySorpRound10Frame
446490MultiSorpRound, C Bottom10Frame
446639MaxiSorpRound10Microplate Strip
448526MaxiSorpRound, Starwell10Microplate Strip
473539PolySorpRound, C Bottom5Microplate Strip
95029390Universal BindingRound, Flat Bottom (F-well)50Microplate Strip
카탈로그 번호 473768
제품 가격(KRW)
1,541,000
Case of 60
카트에 추가하기
표면 처리:
MaxiSorp
웰 형상:
Round, C Bottom
팩당 수:
5
제품 유형:
Strip Plate
제품 가격(KRW)
1,541,000
Case of 60
카트에 추가하기

Choose from four surfaces and a variety of wells and configurations with Thermo Scientific™ Immuno Breakable Modules, which offer reliability, well-to-well reproducibility and an optimal choice of products for the specific assay.

  • Free-standing modules are easy to handle
사양
결합 특성Hydrophilic
결합 유형Adsorption
분리Breakable Strips
인증Yes
설명High optical quality for reliable results
검출 방법Colorimetric
용도(애플리케이션)For antibody sandwich assays
뚜껑Without Lid
케이스당 수60
팩당 수5
포장10 Pk., 60 Cases
플레이트 블로킹None
제품 유형Strip Plate
수량60/Cs.
타겟 분자Antibodies (Glycoproteins)
부피(미터법) 작동250 μL
웰 디자인C8
어레이8 x 12
색상Clear
형식Strip Plate
물질Polystyrene
웰 수96
표면 처리MaxiSorp
부피(미터법) 웰350 μL
웰 형상Round, C Bottom
Unit SizeCase of 60

자주 묻는 질문(FAQ)

What length of peptide is ideal for binding to the Thermo Scientific MaxiSorp surface? What are the detection limitations?

We have tested and found that a 3 amino acid peptide (Pro, Leu, Gly) cannot be detected when passively adsorbed on the MaxiSorp surface. However, this peptide can be detected when covalently immobilized using CovaLink NH Modules and CovaLink NH2 Modules and Plates. Using covalent immobilization of small peptide residues, you can typically obtain a better orientation of the molecule and reduced problems with antibody recognition of the peptide due to masking of the epitope. We have discovered that a 7 amino acid peptide from the MHC Class II antigen can be detected when adsorbed on the MaxiSorp surface. We state that the detection limitation using the MaxiSorp surface is between 3 and 7 amino acid residues.
One additional note is that detection is contingent upon the orientation of the peptide when immobilized. If the active site is inactivated or hidden at the site facing the solid phase, no detection signal is observed.

Can I bind either single- or double-stranded DNA to the Thermo Scientific MaxiSorp surface?

Single-stranded DNA can be adsorbed to our MaxiSorp surface using approximately 10 µg ssDNA per mL PBS, pH 8.2, although the stability is uncertain. Based on our experience, ssDNA immobilized on the MaxiSorp surface is so loosely bound that it can be removed by stringent washing.
Double-stranded DNA will not bind to the MaxiSorp surface. DNA, however, can be covalently bound to Nunc NucleoLink Strips.

For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
- Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
- Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
- "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
- StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

What is the difference between certified and non-certified MaxiSorp plates and modules?

Both of these surfaces are identical. The only difference between them is that for the certified plates, a representative sample from each manufacturing lot undergoes a Binding Capacity test. This test is an ELISA-like assay used in our quality control laboratories to ensure binding capabilities.

How can I reduce high background readings and non-specific binding, when performing ELISA using Nunc-Immuno MaxiSorp Plates?

Assay sensitivity depends strongly on efficient removal of non-specific reacting molecules. High background readings and coating instability can be minimized by addition of a blocking step after the first coating. The excess surface is then occupied by indifferent molecules.
We recommend washing three times after each coating step by using a solution of 0.15 M phosphate buffer (pH 7.2) with 0.2 M NaCl and 0.05% Tween 20.
For blocking, we recommend using 0.5% BSA, 1% casein or 1% gelatin in 0.15 M phosphate buffer (pH 8.2) or carbonate buffer (pH 9.6).