iodoTMTsixplex™ Isobaric Mass Tagging Kit
iodoTMTsixplex™ Isobaric Mass Tagging Kit
iodoTMTsixplex™ Isobaric Mass Tagging Kit
iodoTMTsixplex™ Isobaric Mass Tagging Kit
iodoTMTsixplex™ Isobaric Mass Tagging Kit
Thermo Scientific™

iodoTMTsixplex™ Isobaric Mass Tagging Kit

Thermo Scientific iodoTMTsixplex Isobaric Mass Tag Labeling Kit contains iodoTMT™ reagents and associated materials for the irreversible labeling of sulfhydryl자세히 알아보기
Have Questions?
카탈로그 번호수량
9010330 reactions
카탈로그 번호 90103
제품 가격(KRW)
3,914,000
キャンペーン価格
Ends: 31-Dec-2025
4,604,000
할인액 690,000 (15%)
Each
카트에 추가하기
수량:
30 reactions
대량 주문 또는 맞춤형 요청
제품 가격(KRW)
3,914,000
キャンペーン価格
Ends: 31-Dec-2025
4,604,000
할인액 690,000 (15%)
Each
카트에 추가하기

Thermo Scientific iodoTMTsixplex Isobaric Mass Tag Labeling Kit contains iodoTMT™ reagents and associated materials for the irreversible labeling of sulfhydryl groups. Iodoacetyl Tandem Mass Tag™ Reagents enable selective labeling of cysteine-containing peptides for multiplexed sample quantitation using LC-MS/MS analysis.

The iodoTMT Reagents are sets of isobaric (mass and structure) isomers that are iodoacetyl-activated for covalent, irreversible labeling of sulfhydryl (—SH) groups. Similar to iodoacetamide, iodoTMT Reagents react specifically with reduced cysteines (Cys) in peptides and proteins and enable quantitation of the relative abundance of cysteine modifications, such as S-nitrosylation and the oxidation of disulfide bonds.

The Thermo Scientific iodoTMTzero Label Reagent allows testing and optimization of sample preparation, labeling, fractionation and MS fragmentation for peptide identification and reporter detection without using the more costly isotope-labeled compounds.

Features of the iodoTMT Reagents:
Specific—only reacts with sulfhydryl groups (reduced, unmodified cysteine residues)
Irreversible—labeled proteins and peptides are not susceptible to reducing agents
Flexible—options for duplex isotopic (MS) or sixplex isobaric (MS/MS) quantitation
Versatile—can be used to study cysteine modifications (e.g. di-sulfide bridges, S-nitrosylation)

To selectively analyze the cysteine-labeled peptides, the sample may be enriched using the Thermo Scientific Immobilized Anti-TMT Antibody Resin (Cat. No. 90076) and TMT Elution Buffer (Cat. No. 90104). This approach of selective thiol-labeling and affinity enrichment is similar to isotope-coded affinity tags (ICAT™ Method) but allows for affinity enrichment with a non-biological tag and higher multiplex quantitation.

For Research Use Only. Not for use in diagnostic procedures.
사양
설명iodoTMTsixplex™ Isobaric Mass Tagging Kit
최종 제품 유형Protein
용도(장비)Mass Spectrometer
라벨 또는 염료Tandem Mass Tag™ (TMT) Labels
수량30 reactions
워크플로우 단계Protein Labeling
검출 방법Mass Spectrometry
제품라인iodoTMTsixplex
시작 물질Cell Lysate
Unit SizeEach
구성 및 보관
• iodoTMT6-126 Label Reagent, 5 x 0.2 mg
• iodoTMT6-127 Label Reagent, 5 x 0.2 mg
• iodoTMT6-128 Label Reagent, 5 x 0.2 mg
• iodoTMT6-129 Label Reagent, 5 x 0.2 mg
• iodoTMT6-130 Label Reagent, 5 x 0.2 mg
• iodoTMT6-131 Label Reagent, 5 x 0.2 mg
• HES Buffer, 15 mL
• Bond-Breaker TCEP Solution, 0.5 mL
• DTT, No-Weigh Format, 8 x 7.7 mg
• Trypsin, 5 x 20 μg
• Trypsin Storage Solution, 250 μL
• Albumin (bovine), 2.5 mg

Upon receipt store all products at –20°C

자주 묻는 질문(FAQ)

What is the difference between IodoTMT tags and Iodoacetamido-LC-Phosphonic Acid?

Both IodoTMT tags and Iodoacetamido-LC-Phosphonic Acid react with sulfhydryl groups. Iodo TMT tags allow the quantitation of proteins with cysteine amino acids and the oxidative state of sulfhydryl groups, while Iodoacetamido-LC-Phosphonic Acid allow the detection and enrichment of those specific proteins. This is a great tool for mass spectrometry (MS) analysis, and High-Select Fe-NTA Magnetic Phosphopeptide Enrichment Kit (Cat. No. A52283), can be used for the enrichment step.

Find additional tips, troubleshooting help, and resources within our Mass Spectrometry Support Center.