BrightComp eBeads™ Compensation Bead Kits
BrightComp eBeads™ Compensation Bead Kits
Invitrogen™

BrightComp eBeads™ Compensation Bead Kits

BrightComp eBeads compensation beads provide a consistent, accurate, and simple-to-use technique for setting flow cytometry compensation when using fluorescent protein-expressing samples.
Have Questions?
보기 방식 변경buttonViewtableView
카탈로그 번호설명
A10514GFP BrightComp eBeads Compensation Bead Kit
A54740RFP BrightComp eBeads Compensation Bead Kit
A54741YFP BrightComp eBeads Compensation Bead Kit
A54742CFP BrightComp eBeads Compensation Bead Kit
A54743mCherry BrightComp eBeads Compensation Bead Kit
카탈로그 번호 A10514
제품 가격(KRW)
484,000
Online offer
Ends: 31-Mar-2026
569,000
할인액 85,000 (15%)
Each
카트에 추가하기
설명:
GFP BrightComp eBeads Compensation Bead Kit
제품 가격(KRW)
484,000
Online offer
Ends: 31-Mar-2026
569,000
할인액 85,000 (15%)
Each
카트에 추가하기
BrightComp eBeads compensation beads provide a consistent, accurate, and simple-to-use technique for setting flow cytometry compensation when using fluorescent protein-expressing samples.
• Three levels of intensity, perfect for any samples no matter the level of fluorescent protein expression
• Near-identical, spectrally-matched dye to native protein
• Consistent, reliable performance

Accurate compensation is crucial for effective multicolor analysis in flow cytometry. Each kit provides polystyrene microspheres with near-identical, spectrally-matched fluorescent protein dye as well as negative control beads in a single dropper bottle.
사양
색상Green
설명GFP BrightComp eBeads Compensation Bead Kit
여기 파장 범위488/525
용도(장비)Flow Cytometer
수량25 tests
배송 조건Room Temperature
용도(애플리케이션)Flow Cytometry
제품라인eBeads
제품 유형Compensation Beads
Unit SizeEach
구성 및 보관
Store at 2°C to 8°C. DO NOT FREEZE.

자주 묻는 질문(FAQ)

Can I use the GFP BrightComp eBeads to compensate for FITC or Alexa Fluor 488?

No. You must always compensate with the same fluorophore present on the samples. The GFP BrightComp eBeads Compensation Bead Kit spectrally emulates GFP and must only be used on GFP-expressing samples.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

I used the GFP BrightComp eBeads Compensation Bead Kit. My peaks are broader than what I see in the manual (Figure 1). What is causing this?

This may be caused by aggregation of the beads. Mix thoroughly before dispensing a drop from the stock vial and mix again after adding buffer. Aggregation may be also be caused by microbial contamination or if the beads were frozen. In these cases, they can no longer be used.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

What material are the beads in the GFP BrightComp eBeads Compensation Bead Kit composed of?

These are polystyrene beads.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.