Century™-Plus RNA Markers
Century™-Plus RNA Markers
Invitrogen™

Century™-Plus RNA Markers

Ambion™ RNA Century™-Plus Markers are a set of 7 in vitro transcripts of 100, 200, 300, 400, 500, 750, and자세히 알아보기
Have Questions?
카탈로그 번호수량
AM71451 tube
카탈로그 번호 AM7145
제품 가격(KRW)
250,000
온라인 행사
Ends: 31-Mar-2026
293,000
할인액 43,000 (15%)
Each
카트에 추가하기
수량:
1 tube
대량 주문 또는 맞춤형 요청
제품 가격(KRW)
250,000
온라인 행사
Ends: 31-Mar-2026
293,000
할인액 43,000 (15%)
Each
카트에 추가하기
Ambion™ RNA Century™-Plus Markers are a set of 7 in vitro transcripts of 100, 200, 300, 400, 500, 750, and 1000 bases. They are unlabeled for staining with EtBr and are provided in one tube containing 50 μg at a concentration of 1 mg/mL. They are premixed to give equivalent staining on a 5% polyacrylamide/8 M urea gel and are useful as RNA size standards in denaturing gel electrophoresis. 1–2 μg (2–4 μL) markers will generate 7 distinct bands on a TBE-Urea acrylamide gel with EtBr staining. Markers are also tested to be nuclease-free and stable overnight at 37°C.
For Research Use Only. Not for use in diagnostic procedures.
사양
농도1 mg/ml
젤 호환성Denaturing Agarose Gels, Denaturing Polyacrylamide Gels
질량50 μg
제품라인Ambion, RNA Century
제품 유형RNA Marker
수량1 tube
로드 준비No
배송 조건Dry Ice
크기 범위0.1 to 1 kb
Unit SizeEach
구성 및 보관
Store below –70°C.

자주 묻는 질문(FAQ)

Why are my RNA bands not sharp?

(1) RNA was not completely denatured. Electrophorese RNA under denaturing conditions. Use urea, formamide or formaldehyde gels, or glyoxal-treated RNA.

(2) For glyoxal-treated RNA, a buffer gradient formed during electrophoresis. Recirculate buffer during electrophoresis to prevent gradient formation.

What is the cause of extra bands when using an RNA ladder?

Extra bands appear in RNA Ladders for a few reasons:

(1) RNA was not completely denatured. Electrophorese RNA under denaturing conditions. Use urea, formamide or formaldehyde gels, or glyoxal-treated RNA.

(2) Extra bands may be a result of using formaldehyde that is not fresh; the pH becomes acidic in older formaldehyde. In our hands, when fresh formaldehyde with neutral pH was used, the extra bands disappeared.

(3) Alternatively, if the extra bands appear after hybridization, it could be that the gel purified probe contains contaminating vector DNA (pUC or pBR) that hybridizes to RNA Ladder template DNA.

Why are some of the RNA marker bands not visible?

Missing RNA bands may be due to:

(1) A small amount of RNA diffused out of gel during extended destaining. Minimize destaining time. Destaining for 2 hours is sufficient for most applications.

(2) RNA bands of similar molecular size were not resolved. Use the correct gel type and denaturing conditions.

Why are the RNA bands disappearing when looking and photographing a gel on a UV box?

RNA was exposed to UV light for extended periods of time. Minimize exposure to UV light. Stain and destain gels in the dark and photograph the gel immediately.

Why are the RNA marker bands so faint?

Many factors could affect the intensity of the bands as summarized below.

(1) Insufficient RNA was loaded on the gel. Increase the amount of RNA loaded.

(2) RNA was degraded. Avoid nuclease contamination of the RNA standards. Store RNA at -70 degrees C in formamide. Deionize formamide and glyoxal, store aliquots at -20 degrees C.

(3) RNA was electrophoresed off the gel. Electrophorese the gel for less time, at a lower voltage, or in a higher percentage gel.

(4) For ethidium bromide-stained RNA, improper UV light source was used. Use short-wavelength (254 nm) UV light. For ethidium bromide-stained RNA, improper staining and destaining conditions were used. Stain in the dark with 5 mg/mL ethidium bromide. For thin (3.2 mm) formaldehyde gels, stain 5 min and destain 1 h. For thicker gels, stain 30 min and destain 2 hr. To reduce background staining, use 0.66 M formaldehyde instead of 2.2 M formaldehyde in gels. For glyoxal RNA gels, stain and destain in 0.5 M ammonium acetate to help reduce background staining.

(5) For radiolabeled RNA, an improper labeling method was used.