Click-iT™ EdU Colorimetric IHC Detection Kit
FWS 제품은 특정 승인이 필요하므로 배송이 약 2-3주 더 소요됩니다.
Click-iT™ EdU Colorimetric IHC Detection Kit
Invitrogen™

Click-iT™ EdU Colorimetric IHC Detection Kit

The Click-iT™ EdU Colorimetric IHC (Immunohistochemistry) Detection Kit is a superior alternative to traditional methods for the colorimetric detection of자세히 알아보기
Have Questions?
카탈로그 번호수량
C1064450 Slides
카탈로그 번호 C10644
제품 가격(KRW)
954,000
온라인 행사
Ends: 31-Dec-2025
1,192,000
할인액 238,000 (20%)
Each
카트에 추가하기
수량:
50 Slides
제품 가격(KRW)
954,000
온라인 행사
Ends: 31-Dec-2025
1,192,000
할인액 238,000 (20%)
Each
카트에 추가하기
The Click-iT™ EdU Colorimetric IHC (Immunohistochemistry) Detection Kit is a superior alternative to traditional methods for the colorimetric detection of proliferating cells within tissue sections. In this assay, 5-ethynyl-2'-deoxyuridine (EdU), a nucleoside analog of thymidine containing an alkyne moiety, is incorporated into newly synthesized DNA. When biotin containing an azide group is added, a brief 'click reaction' attaches the azide to the alkyne moiety on the EdU molecule. Upon addition of streptavidin–peroxidase and a peroxidase substrate, an enzymatic reaction generates a signal that can be detected with light microscopy and stored for future analysis.

Find more tools for image-based detection of proliferating cells >

• Optimized—enables colorimetric detection of proliferating cells in either tissue or cell samples
• Efficient—no denaturation steps or harsh treatment required
• Robust—improved preservation of cell morphology and the cellular environment offers content-rich results
• Consistent—not dependent on variable antibody lots for detection
• Simple—designed to work consistently, in less time than traditional methods

Traditional methods yield inconsistent results
Measuring changes to cell proliferation is a fundamental method for assessing cell health, determining genotoxicity, and evaluating anti-cancer drug research. The most accurate method of doing this is by directly measuring DNA synthesis. The traditional method utilizes the nucleoside analog 5-bromo-2'-deoxyuridine (BrdU), a nucleoside analog of thymidine, which is incorporated into newly transcribed DNA. After incorporation, the samples are treated with harsh methods (HCl, heat, or enzymes) to denature the DNA and expose the BrdU molecules to detection by anti-BrdU antibodies. These harsh treatments can adversely affect sample integrity, cell morphology, and image quality. In addition, manufacturing variability, nonspecific binding, and cross-reactivity issues can result in inconsistent results.

Advantages over other assays
The Click-iT EdU Colorimetric IHC Detection Kit offers many advantages over traditional methods like the BrdU assay. The small size of the biotin-azide moiety allows efficient detection of incorporated EdU using mild conditions. In contrast, BrdU assays require harsh denaturation methods using HCl and/or heat-induced epitope retrieval (HIER). Additionally, unlike the BrdU assay, which relies on antibodies that can sometimes exhibit nonspecific binding, the Click-iT EdU Colorimetric IHC Detection Kit utilizes a bioorthogonal (biologically unique) moiety—resulting in low background signal, high detection sensitivities, and no cross-reactivity issues.

The kit contains all the components needed to detect incorporated EdU present in formalin-fixed, paraffin-embedded (FFPE) tissue samples. The kit includes sufficient reagents for labeling fifty (50) 18 x 18 mm coverslips using 100 μL reaction reagent per test.
For Research Use Only. Not for use in diagnostic procedures.
사양
검출 방법Colorimetric
용도(애플리케이션)IHC (Immunohistochemistry)
용도(장비)EVOS™ XL Core Imaging System, EVOS™ XL Imaging System
포장Slides
제품 유형IHC Detection Kit
수량50 Slides
배송 조건Wet Ice
기질DAB
기질 유형HRP
타겟 종All species
콘주게이트HRP
제품라인Click-iT
Unit SizeEach
구성 및 보관
Store at 2°C to 8°C.

자주 묻는 질문(FAQ)

I have the Click-iT EdU Colorimetric IHC Detection Kit, but have decided that I want to use a fluorescent label but I don't want to buy another kit. What can I do?

You need to only substitute the peroxidase-conjugated streptavidin with a dye-conjugated streptavidin and not use the DAB. You would have to optimize the final concentration of the dye-conjugated streptavidin to use.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

Can other peroxidase substrates be used with the Click-iT EdU Colorimetric IHC Detection Kit instead of the DAB?

Yes, but we have not optimized the amount of substrate to use. The labeling may be punctate and therefore an intense dark label such as DAB is recommended.

Find additional tips, troubleshooting help, and resources within our Cell Analysis Support Center.

인용 및 참조 문헌 (1)

인용 및 참조 문헌
Abstract
A Whole Brain Staining, Embedding, and Clearing Pipeline for Adult Zebrafish to Visualize Cell Proliferation and Morphology in 3-Dimensions.
Authors:Lindsey BW, Douek AM, Loosli F, Kaslin J,
Journal:Front Neurosci
PubMed ID:29386991
'The field of macro-imaging has grown considerably with the appearance of innovative clearing methods and confocal microscopes with lasers capable of penetrating increasing tissue depths. The ability to visualize and model the growth of whole organs as they develop from birth, or with manipulation, disease or injury, provides new ways ... More