Invitrogen™

DAF-FM (4-Amino-5-Methylamino-2',7'-Difluorofluorescein)

카탈로그 번호: D23841
Invitrogen™

DAF-FM (4-Amino-5-Methylamino-2',7'-Difluorofluorescein)

카탈로그 번호: D23841
카탈로그 번호
D23841
D-23841으로도 사용됨
제품 사이즈
1 mg
제품 정가(KRW)
제품 정가 1,099,000
온라인 행사 879,200
(01-Jul-2024에 종료)
공급가
재고 정보
***
수량
카탈로그 번호제품 사이즈제품 정가(KRW)재고 정보수량
D23841
D-23841으로도 사용됨
1 mg
제품 정가 1,099,000
온라인 행사 879,200
(01-Jul-2024에 종료)
공급가
***
제품 개요
그림
동영상
관련 제품 추천
관련 제품 추천
문서
FAQ
인용 및 참조 문헌
추가 정보
관련 제품 추천
DAF-FM is a reagent that is used to detect and quantify low concentrations of nitric oxide (NO). It is essentially nonfluorescent until it reacts with NO to form a fluorescent benzotriazole. DAF-FM fluorescence can be detected by any instrument that can detect fluorescein, including flow cytometers, microscopes, fluorescent microplate readers and fluorometers.

DAF-FM Specifications:
• Ex/Em of DAF-FM: ∼495/515 nm
• Lyophilized product should be dissolved using DMSO and then added to an aqueous buffer to create a working solution
• DAF-FM can be introduced into cells by pressure injection or perfusion from a patch-clamp pipette (choose DAF-FM diacetate if you need a cell-permeant version)
• Buffers containing bovine serum albumin (BSA) and phenol red may affect the fluorescence and should be used with caution
• The fluorescence quantum yield of DAF-FM is ∼0.005, but increases about 160-fold, to ∼0.81, after reacting with NO


Applications of DAF-FM:
• Assessment of NO production in transaldolase-deficient lymphoblasts by flow cytometry
• Detection of NO accumulation in embryonic cortical neurons following neurotrophin stimulation
in vivo imaging of NO in zebrafish
• Intravital microscopic detection of NO generation associated with angiogenesis in mice
• Quantitation of ATP-induced NO release in rabbit platelets

Important Advantages of DAF-FM Over DAF-2
The spectra of the NO adduct of DAF-FM are independent of pH above pH 5.5. Also, the NO adduct of DAF-FM is significantly more photostable than that of DAF-2, which means additional time for image capture. Finally, DAF-FM is a more sensitive reagent for NO than is DAF-2 (NO detection limit for DAF-FM ∼3 nM versus ∼5 nM for DAF-2).

Probes for Nitric Oxide Research
We offer several products for the detection of reactive oxygen species (ROS) and nitric oxide (NO). Review these products in Probes for Nitric Oxide Research—Section 18.3 in the Molecular Probes™ Handbook.

For Research Use Only. Not for human or animal therapeutic or diagnostic use.
For Research Use Only. Not for use in diagnostic procedures.

사양

인디케이터 특성
Fluorescent Dye-Based
배송 조건
Room Temperature
Excitation/Emission
495/515 nm
Indicator
Free Radical Sensor
제품라인
Invitrogen™

그림

문서 및 다운로드

Certificates | 증명서

    자주 묻는 질문(FAQ)

    인용 및 참조 문헌

    Search citations by name, author, journal title or abstract text