ProcartaPlex™ Reading Buffer
ProcartaPlex™ Reading Buffer
Invitrogen™

ProcartaPlex™ Reading Buffer

The ProcartaPlex Reading Buffer is included in our basic kits and off the shelf panels. Additionally, we offer the Reading자세히 알아보기
Have Questions?
카탈로그 번호수량
EPX-77777-0001 Ea.
카탈로그 번호 EPX-77777-000
제품 가격(KRW)
92,000
線上優惠
Ends: 31-Mar-2026
108,000
할인액 16,000 (15%)
Each
카트에 추가하기
수량:
1 Ea.
제품 가격(KRW)
92,000
線上優惠
Ends: 31-Mar-2026
108,000
할인액 16,000 (15%)
Each
카트에 추가하기

The ProcartaPlex Reading Buffer is included in our basic kits and off the shelf panels. Additionally, we offer the Reading Buffer as a stand-alone item.

Reported Application

  • Multiplex Immunoassay
For Research Use Only. Not for use in diagnostic procedures.
사양
용도(장비)Luminex™ Instruments
형태Liquid
제품라인ProcartaPlex
제품 유형Buffer
수량1 Ea.
Unit SizeEach

자주 묻는 질문(FAQ)

Do you offer a Mac-compatible version of the ProcartaPlex Analyst Software?

Unfortunately, we do not currently offer a Mac-compatible version of the ProcartaPlex Analyst Software. ProcartaPlex Analyst Software is compatible with PC, or xPONENT Software is available on Luminex instruments to analyze your data.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

I am getting poor recovery with my ProcartaPlex multiplex immunoassay. What can I do?

Here are possible causes and solutions:
- The wrong cell culture media may have been used to prepare the standards. We recommend using the same cell culture media that was used to culture the cells.
- The samples and antigen standards may not have been stored on ice. We recommend preparing the samples and standards on ice before setting up the assay.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

I am seeing low signal or sensitivity in my ProcartaPlex multiplex immunoassay. What should I do?

Standards may not have been reconstituted and diluted correctly. We recommend preparing fresh antigen standards following the instructions provided in the corresponding ProcartaPlex user guide.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

With my ProcartaPlex multiplex immunoassay, I am getting a low bead count. What is causing this?

Here are possible causes and solutions:
- Volume of the bead solution is too low. We recommend adding 120 µL Reading Buffer into each well and shaking at 600 rpm for 5 mins at room temperature to resuspend beads before reading on the Luminex instrument.
- High bead aggregation. We recommend vortexing the bead suspension well before using in the assay and ensuring that the beads are properly mixed during the incubation steps.
- Dyes contained in the beads are photo-bleached from overexposure to light. We recommend storing the bead solution and the 96-well plate in the dark.
- Samples causing the instrument to clog. We recommend removing the 96-well Flat Bottom Plate and performing a wash and rinse to the instrument and then re-running the assay with further dilution of samples.
- Probe height is incorrect. We recommend referring to the Luminex manual for proper adjustment of the needle height.
- The instrument needle is partially clogged. We recommend replacing or cleaning the needle according to the manufacturer's recommendations.
- Beads stuck to the bottom of the plate. We recommend confirming that the plate shaker is set to 600 rpm and shaking for at least 5 mins before reading.
- Air bubble in the sample loop. We recommend referring to the specific Luminex manual for your assay for proper removal of the air bubble.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

In ProcartaPlex multiplex immunoassays, we are seeing a limited dynamic range for BioPlex software users. Why is this?

The instrument may have been calibrated at high PMT settings. We recommend calibrating the instrument using the CAL2 Low RP1 target value.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.