FocalCheck™ Fluorescence Microscope Test Slide #2, for spectral imaging systems
FocalCheck™ Fluorescence Microscope Test Slide #2, for spectral imaging systems
Invitrogen™

FocalCheck™ Fluorescence Microscope Test Slide #2, for spectral imaging systems

The FocalCheck™ fluorescence microscope test slide #2 is specifically designed for calibrating fluorescence microscope systems and evaluating system and filter자세히 알아보기
Have Questions?
카탈로그 번호수량
F369131 Ea.
카탈로그 번호 F36913
제품 가격(KRW)
670,000
Online offer
Ends: 31-Mar-2026
788,000
할인액 118,000 (15%)
Each
카트에 추가하기
수량:
1 Ea.
제품 가격(KRW)
670,000
Online offer
Ends: 31-Mar-2026
788,000
할인액 118,000 (15%)
Each
카트에 추가하기
The FocalCheck™ fluorescence microscope test slide #2 is specifically designed for calibrating fluorescence microscope systems and evaluating system and filter performance. This slide provides a robust, reproducible method of evaluating the performance of spectral imaging systems, as well as the ability to discriminate closely overlapping spectra. The slide consists of 6 μm-diameter microspheres labeled with a series of spectrally overlapping dyes.

See our full collection of microscope calibration reagents ›

For Research Use Only. Not for use in diagnostic procedures.
사양
보정 유형Confocal Microscope Calibration, Fluorescence Microscope Calibration
용도(장비)Spectral Imaging System
형식Suspension Beads
제품라인FocalCheck
수량1 Ea.
배송 조건Room Temperature
색상Assorted Colors
직경(미터법)6 μm
제품 유형Fluorescence Microscope Test Slide
Unit SizeEach
구성 및 보관
Store at room temperature.

인용 및 참조 문헌 (3)

인용 및 참조 문헌
Abstract
Quality assessment of confocal microscopy slide-based systems: instability.
Authors:Zucker RM
Journal:Cytometry A
PubMed ID:16807898
'BACKGROUND: All slide-based fluorescence cytometry detections systems basically include an excitation light source, intermediate optics, and a detection device (CCD or PMT). Occasionally, this equipment becomes unstable, generating unreliable and inferior data. METHODS: A number of tests have been devised to evaluate equipment performance and instability. The following four instability ... More
Reliability of confocal microscopy spectral imaging systems: use of multispectral beads.
Authors:Zucker RM, Rigby P, Clements I, Salmon W, Chua M,
Journal:Cytometry A
PubMed ID:17266146
BACKGROUND: There is a need for a standardized, impartial calibration, and validation protocol on confocal spectral imaging (CSI) microscope systems. To achieve this goal, it is necessary to have testing tools to provide a reproducible way to evaluate instrument performance. METHODS: We evaluated fluorescent spectral beads (FocalCheck) from Molecular Probes/Invitrogen ... More
Lenslet array tunable snapshot imaging spectrometer (LATIS) for hyperspectral fluorescence microscopy.
Authors:Dwight JG, Tkaczyk TS
Journal:Biomed Opt Express
PubMed ID:28663875
Snapshot hyperspectral imaging augments pixel dwell time and acquisition speeds over existing scanning systems, making it a powerful tool for fluorescence microscopy. While most snapshot systems contain fixed datacube parameters (x,y,?), our novel snapshot system, called the lenslet array tunable snapshot imaging spectrometer (LATIS), demonstrates tuning its average spectral resolution ... More