HP-210/HP-360 Series Pancake Geiger-Mueller Detectors
Actual product may vary
HP-210/HP-360 Series Pancake Geiger-Mueller Detectors
HP-210/HP-360 Series Pancake Geiger-Mueller Detectors
Thermo Scientific™

HP-210/HP-360 Series Pancake Geiger-Mueller Detectors

Prevent the spread of radioactive contamination in your lab with sensitive pancake Geiger-Mueller radiation detectors designed for frequent surface contamination surveys.
Have Questions?
보기 방식 변경buttonViewtableView
카탈로그 번호설명커넥터 유형
HP210TTungsten ShieldMHV Connector
HP360HP-360 Geiger-Mueller Pancake ProbeMHV Connector
카탈로그 번호 HP210T
제품 가격(KRW)
-
설명:
Tungsten Shield
커넥터 유형:
MHV Connector

Workplace safety in facilities that use radiation depends on frequent surveys to detect spills and prevent the spread of contamination in and beyond the lab. Thermo Scientific™ HP-210/HP-360 Series Pancake Geiger-Mueller Detectors are designed for daily contamination surveys on personnel, table tops, floors, equipment and any surfaces that could be exposed to radioactive material. Featuring a thin mica window protected by a stainless steel screen, HP-210/HP-360 meters permit sensitive detection of beta-emitting surface contamination that meets the environmental health and safety requirements of your lab.

HP-210/HP-360 Series Pancake Geiger-Mueller Detectors handheld probes provide sensitive alpha and beta detection featuring a “Pancake” Geiger-Mueller tube with a thin mica window.

General features of both probes:

  • Open mica window protected by an etched stainless steel screen.
  • High beta sensitivity; permits useful beta sensitivities down to 40keV and is alpha sensitive above 3MeV.

Features of the HP-210 Series Pancake Geiger-Mueller Detectors

  • With optional sample holder “SH4A.”
  • The two versions offer both integrated shielding against radiation:
  • HP-210T, with a high density tungsten shield, permits relatively low level beta monitoring in a gamma background; HP-210AL for low-level beta monitoring in a low background area; aluminum housing may be used.

Features of the HP-360 Geiger-Mueller Pancake Probe

  • Capable of seeing low energy photons down to approximately 10keV.
  • Economic product design with ergonomic enclosure constructed from rugged ABS plastic.
사양
커넥터 유형MHV Connector
설명Tungsten Shield
작동 온도(영국식 단위)-22°F to 167°F
작동 온도(미터법)−30°C to 75°C
전원 공급 장치900 ± 50V
민감도Alpha (3 MeV at window)
두께(미터법) 창1.4 to 2.0 mg/cm2
중량(영국식 단위)1.5 lb.
창 크기1.75 in.
효율Beta: With Screen: 22% 13cCs, 16% 60Co, 32% 90Sr/90Y, 15% 99Tc, 6% 14Cs; Without Screen: 33% 13cCs, 22% 60Co, 37% 90Sr/90Y, 20% 99Tc, 9% 14Cs
제품 유형Pancake Geiger-Mueller Detector
방사선 유형Alpha, Beta
중량(미터법)0.7 kg
Unit SizeEach