Neon™ NxT Electroporation System 1-Channel Tubes
Neon™ NxT Electroporation System 1-Channel Tubes
Invitrogen™

Neon™ NxT Electroporation System 1-Channel Tubes

Neon NxT Electroporation System 1-Channel Tubes are designed specifically for use with the Neon NxT Electroporation System with 1-Channel Pipette.
Have Questions?
보기 방식 변경buttonViewtableView
카탈로그 번호수량
NT9696 tubes, 96 tubes
NT2424 Tubes, 24 Tubes
카탈로그 번호 NT96
제품 가격(KRW)
848,000
온라인 행사
Ends: 31-Mar-2026
942,000
할인액 94,000 (10%)
Each
카트에 추가하기
수량:
96 tubes, 96 tubes
제품 가격(KRW)
848,000
온라인 행사
Ends: 31-Mar-2026
942,000
할인액 94,000 (10%)
Each
카트에 추가하기

Neon NxT Electroporation System 1-Channel Tubes are designed specifically for use with the Neon NxT Electroporation System with 1-Channel Pipette (Cat. Nos. NEON1S, NEON1SK, NEON18S, NEON18SK). Each Neon NxT Electroporation System Kit for 25 x 2 reactions (Cat. Nos. N1025 and N10025) comes with eight 1-channel tubes, and each Neon NxT Electroporation System Kit with 1-Channel Tubes for 96 x 2 reactions (Cat. Nos. N1096 and N10096) comes with 32 1-channel tubes. This pack of additional tubes is offered for those wishing to use single tubes per reaction depending on their experimental setup or for reactions with the 1-channel pipette when predominately using the 8-channel pipette and utilizing kits that contain the 8-channel tubes.

For Research Use Only. Not for use in diagnostic procedures.
사양
용도(애플리케이션)Transfection
용도(장비)Neon™ NxT Electroporation System
수량96 tubes, 96 tubes
셀 유형Stem Cells, Primary Cells, Hard-to-Transfect Cells
용도(애플리케이션)Electroporation
용도 (장비)Neon™ NxT Electroporation System
형식Electroporation Pipette Tip
Transfection TechniqueElectroporation
Unit SizeEach

자주 묻는 질문(FAQ)

How are the Neon NxT Electroporation System 1-Channel Tubes (Cat. No. NT24 and NT96) packaged?

The tubes are packaged in groups of 4. Therefore, Cat. No. NT24 will have 6 bags of 4 tubes and Cat. No. NT96 will have 24 bags of 4 tubes.

Find additional tips, troubleshooting help, and resources within our Transfection Support Center.

What state should the cells be in for best results with the Neon Nxt Electoporation System?

For best results with the Neon Nxt Electoporation System, the cells should be healthy (not stressed) and actively dividing so that the nuclear membrane integrity is already weakened for payload needing to enter the nucleus. Consider “starving” the cells of serum or other essential nutrients.

Find additional tips, troubleshooting help, and resources within our Transfection Support Center.

I'm experiencing arcing issues with the Neon Nxt Electoporation System. What could be causing this?

Arcing could be caused by high voltage or pulse length settings, high salt or contaminants in the DNA sample, incorrect cell density, and air bubbles formed during mixing of cell samples. Mix samples gently to avoid air bubble formation and pipette samples in a slow, smooth motion to avoid air uptake.

Find additional tips, troubleshooting help, and resources within our Transfection Support Center.

After electroporation using the Neon NxT Electroporation System, how long should I wait before analyzing protein expression?

The optimal time for analysis of protein expression is dependent upon the stability of the protein being expressed. For a short-lived protein, like luciferase, analysis of protein expression should be done at 6-18 hours after electroporation. For a more stable protein, such as GFP, you should start the analysis at 24 hours or longer post-electroporation.

Find additional tips, troubleshooting help, and resources within our Transfection Support Center.

What is the best time for analysis of CRISPR/Cas9-based KO/KI application in T cells after electroporation using the Neon NxT Electroporation System?

We recommend analyzing the cells 72 hours post-electroporation.

Find additional tips, troubleshooting help, and resources within our Transfection Support Center.