Column Type | Analytical Column |
Crosslinking | 55% DVB |
Column Capacity | 940 μeq |
Column Chemistry | Acidic |
Flow Rate | 0.5 to 1.0 mL/min. |
For Use With (Application) | Cation Exchange |
For Use With (Equipment) | CSRS |
Hydrophobicity | Medium |
Max. Pressure | 4000 psi (275 bar) |
Solvent Compatibility | Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided |
Particle Size | 5 μm |
Stationary Phase | IonPac CS12A-5μm |
Format | Microbore |
Packing Material | Ethylvinylbenzene/Divinylbenzene |
Solvents | 0 to 100% Acetonitrile. Alcohols Should be Avoided. |
Length (Metric) | 150 mm |
Diameter (Metric) | 3 mm |
Unit Size | Each 1 |
Column Type | Analytical Column |
Crosslinking | 55% DVB |
Column Capacity | 2800 μeq |
Column Chemistry | Acidic |
Flow Rate | 1.0 to 2.0 mL/min. |
For Use With (Application) | Cation Exchange |
For Use With (Equipment) | CSRS |
Hydrophobicity | Medium |
Max. Pressure | 4000 psi (275 bar) |
Solvent Compatibility | Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided |
Particle Size | 8 μm |
Stationary Phase | IonPac CS12A-8μm |
Format | Standard Bore |
Packing Material | Ethylvinylbenzene/Divinylbenzene |
Solvents | 0 to 100% Acetonitrile. Alcohols Should be Avoided. |
Length (Metric) | 250 mm |
Diameter (Metric) | 4 mm |
Unit Size | Each 1 |
Column Type | Guard Column |
Description | CG12 A-8 um (4 x 50 mm) |
Column Chemistry | Acidic |
For Use With (Application) | Cation Separation |
For Use With (Equipment) | Separation of Cations |
Hydrophobicity | Medium |
Max. Pressure | 4000 psi (275 bar) |
Solvent Compatibility | Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided |
Particle Size | 8 μm |
Stationary Phase | IonPac CG12A-8μm |
Format | Standard Bore |
Length (Metric) | 50 mm |
Diameter (Metric) | 4 mm |
Unit Size | Each 1 |
Column Type | Analytical Column |
Crosslinking | 55% DVB |
Column Capacity | 700 μeq |
Column Chemistry | Acidic |
Flow Rate | 0.25 to 0.5 mL/min. |
For Use With (Application) | Cation Exchange |
For Use With (Equipment) | CSRS |
Hydrophobicity | Medium |
Max. Pressure | 4000 psi (275 bar) |
Solvent Compatibility | Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided |
Particle Size | 8 μm |
Stationary Phase | IonPac CS12A-8μm |
Format | Microbore |
Packing Material | Ethylvinylbenzene/Divinylbenzene |
Solvents | 0 to 100% Acetonitrile. Alcohols Should be Avoided. |
Length (Metric) | 250 mm |
Diameter (Metric) | 2 mm |
Unit Size | Each 1 |
Column Type | Guard Column |
Description | CG12 A-8 um (2 x 50 mm) |
Column Chemistry | Acidic |
For Use With (Application) | Cation Separation |
For Use With (Equipment) | Separation of Cations |
Hydrophobicity | Medium |
Max. Pressure | 4000 psi (275 bar) |
Solvent Compatibility | Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided |
Particle Size | 8 μm |
Stationary Phase | IonPac CG12A-8μm |
Format | Microbore |
Length (Metric) | 50 mm |
Diameter (Metric) | 2 mm |
Unit Size | Each 1 |
Column Type | Guard Column |
Description | CG12 A-5 μm (3 x 30 mm) |
Column Chemistry | Acidic |
For Use With (Application) | Cation Separation |
For Use With (Equipment) | Separation of Cations |
Hydrophobicity | Medium |
Max. Pressure | 4000 psi (275 bar) |
Solvent Compatibility | Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided |
Particle Size | 5 μm |
Stationary Phase | IonPac CG12A-5μm |
Format | Microbore |
Length (Metric) | 30 mm |
Diameter (Metric) | 3 mm |
Unit Size | Each 1 |
Column Type | Analytical Column |
Crosslinking | 55% DVB |
Description | CS12 A-MS-8 μm (2 x 100 mm) |
Column Capacity | 280 μeq |
Column Chemistry | Acidic |
Flow Rate | 0.25 to 0.75 mL/min. |
For Use With (Application) | IC-MS, Cation Exchange |
For Use With (Equipment) | IC-MS Systems |
Hydrophobicity | Medium |
Max. Pressure | 4000 psi (275 bar) |
Solvent Compatibility | Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided |
Particle Size | 8 μm |
Stationary Phase | IonPac CS12A-MS |
Format | Microbore |
Packing Material | Ethylvinylbenzene/Divinylbenzene |
Solvents | 0 to 100% Acetonitrile. Alcohols Should be Avoided. |
Length (Metric) | 100 mm |
Diameter (Metric) | 2 mm |
Unit Size | Each 1 |
Column Type | Guard Column |
Column Chemistry | Acidic |
For Use With (Application) | IC-MS |
For Use With (Equipment) | IC-MS Systems |
Hydrophobicity | Medium |
Max. Pressure | 5000 psi (345 bar) |
Solvent Compatibility | Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided |
Particle Size | 8 μm |
Stationary Phase | IonPac CG12A-8μm |
Format | Capillary |
Length (Metric) | 50 mm |
Diameter (Metric) | 0.4 mm |
Unit Size | Each 1 |
Column Type | Capillary Column |
Crosslinking | 55% DVB |
Column Capacity | 9.4 μeq |
Column Chemistry | Acidic |
Flow Rate | 0.008 to 0.20 mL/min. |
For Use With (Application) | Separation of Group I and II Cations, Cation Exchange |
For Use With (Equipment) | Separation of Group I and II Cations |
Hydrophobicity | Medium |
Max. Pressure | 5000 psi (345 bar) |
Solvent Compatibility | Acidic Eluents, 0 to 100% Acetonitrile, Alcohols Should be Avoided |
Particle Size | 5 μm |
Stationary Phase | IonPac CS12A-5μm |
Format | Capillary |
Packing Material | Ethylvinylbenzene/Divinylbenzene |
Solvents | 0 to 100% Acetonitrile. Alcohols Should be Avoided. |
Length (Metric) | 150 mm |
Diameter (Metric) | 0.4 mm |
Unit Size | Each 1 |
Column Type | Guard Column |
Column Chemistry | Acidic |
For Use With (Application) | IC-MS |
For Use With (Equipment) | IC-MS Systems |
Hydrophobicity | Medium |
Max. Pressure | 5000 psi (345 bar) |
Solvent Compatibility | Acidic Eluents, 100% Acetonitrile, Alcohols Should be Avoided |
Particle Size | 5 μm |
Stationary Phase | IonPac CS12A-5μm |
Format | Capillary |
Length (Metric) | 35 mm |
Diameter (Metric) | 0.4 mm |
Unit Size | Each 1 |
Catalog Number | Specifications | Unit Size | Column Type | Diameter (Metric) | Length (Metric) | Price (MXN) | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
057185 | Each 1 | Analytical Column | 3 mm | 150 mm | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
046073 | Each 1 | Analytical Column | 4 mm | 250 mm | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
046074 | Each 1 | Guard Column | 4 mm | 50 mm | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
046075 | Each 1 | Analytical Column | 2 mm | 250 mm | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
046076 | Each 1 | Guard Column | 2 mm | 50 mm | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
057184 | Each 1 | Guard Column | 3 mm | 30 mm | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
059960 | Each 1 | Analytical Column | 2 mm | 100 mm | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
072067 | Each 1 | Guard Column | 0.4 mm | 50 mm | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
072068 | Each 1 | Capillary Column | 0.4 mm | 150 mm | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
072069 | Each 1 | Guard Column | 0.4 mm | 35 mm | Contact Us › | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
The Dionex IonPac CS12A-8μm and CS12A-5μm Capillary Columns offer the same selectivity as their analytical-scale counterparts with lowering operating costs.
Recommended for Common Cations and Ammonium in Diverse Sample MatricesThe Dionex IonPac CS12A capillary columns provide the same performance as the standard bore and microbore Dionex IonPac CS12A columns because they are packed with the same material. Operating costs are reduced because the capillary system operates at only 1% of the eluent flow rate of the standard bore system, requiring less eluent and producing less waste.
Multiple Formats Available for Application Flexibility