DS-30 Matrix Standard Kit (Dye Set D)
DS-30 Matrix Standard Kit (Dye Set D)
Applied Biosystems™

DS-30 Matrix Standard Kit (Dye Set D)

El kit DS-30 de patrón de matriz contiene 4 oligonucleótidos etiquetados respectivamente con 6-FAM™, HEX™, NED™y ROX™, previamente agrupados enMás información
Have Questions?
Número de catálogoCantidad
43458278 procesamientos
Número de catálogo 4345827
Precio (MXN)
-
Cantidad:
8 procesamientos
El kit DS-30 de patrón de matriz contiene 4 oligonucleótidos etiquetados respectivamente con 6-FAM™, HEX™, NED™y ROX™, previamente agrupados en un solo tubo.Este conjunto de patrones de matriz se utiliza para generar la “matriz multicomponente” necesaria al analizar fragmentos de ADN con etiqueta de colorante fluorescente en los sistemas Applied Biosystems™ de las series 3100 y 3130.El software de recopilación de datos para estos instrumentos utiliza la matriz de multicomponentes para analizar automáticamente las cuatro muestras etiquetadas con tintes fluorescentes diferentes en un solo capilar.

Para uso exclusivo en investigación.No apto para uso en procedimientos diagnósticos.
Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
Para utilizar con (equipo)™Instrumentos de las series SeqStudio , 3500, 3730xl y 3130
Cantidad8 procesamientos
Almacenamiento recomendadoContiene 4 oligonucleótidos etiquetados respectivamente con 6FAM™, HEX™, NED™ y. ROX™.Para calibración espectral del conjunto de colorantes D.Almacenar el kit entre 2 y 8 °C.No la congele.
Condiciones de envíoHielo húmedo
Unit SizeEach

Preguntas frecuentes

What is a spectral calibration?

A spectral calibration is an algorithm applied to raw data, which converts it into the component 4 or 5 dye data stored in the sample files. A spectral is created for a specific dye set (combination of dyes), array type (4 or 16 capillaries), and array length (36cm or 50cm). It is used to correct for the natural overlap of the fluorescent dyes.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Instruments Support Center.

Which fragment analysis matrix standards can I use for my Applied Biosystems 3130 Series instrument?

DS-02 (Dye Set E5), DS-30 (Dye Set D), DS-31 (Dye Set D), DS-32 (Dye Set F), and DS-33 (Dye Set G5) are all supported on the Applied Biosystems 3130 Series systems. Please refer to the Applied Biosystems 3130/3130xl Genetic Analyzers Getting Started Guide (http://tools.thermofisher.com/content/sfs/manuals/cms_041468.pdf) for more information.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Applications Support Center.

I am using only one dye for fragment analysis but I see peaks in other colors below my peak of interest. Why is this?

If the peaks in other colors are directly below the peak of interest, the issue could be that the fluorescent dye being used is not part of the selected dye set, the spectral calibration needs to be performed, or the peaks are offscale. Confirm that the dye set selected on the instrument is compatible with the dye being used, run a new spectral calibration if the correct dye set has been selected and, if the signal intensity is too high, decrease sample concentration during PCR or when preparing samples for electrophoresis.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Applications Support Center.

Can I switch dyes during a fragment analysis project?

We do not recommend that you switch dyes in the middle of a project. Switching dyes may result in a shift in the allele sizes as dyes differ in their mobility. If dyes are switched in the middle of a project, it will be necessary to identify the size shift for all the markers/targets in the amplicon product range. The size shift will be consistent throughout the project and it is only necessary to make the adjustment once.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Applications Support Center.

What is a dye set?

A dye set is a combination of dyes that have minimum spectral overlap, which will allow you to multiplex products of similar size using different dyes. Although the size ranges may overlap, the use of a different dye will allow the software to easily distinguish between these products.