Placas blancas de 96 pocillos para inmunoanálisis
Placas blancas de 96 pocillos para inmunoanálisis
Placas blancas de 96 pocillos para inmunoanálisis
Placas blancas de 96 pocillos para inmunoanálisis
Placas blancas de 96 pocillos para inmunoanálisis
Placas blancas de 96 pocillos para inmunoanálisis
Thermo Scientific™

Placas blancas de 96 pocillos para inmunoanálisis

Lleve a cabo inmunoensayos cuantitativos y cualitativos como ELISA, así como ensayos de unión con estas placas blancas de 96 pocillos para inmunoensayos.
Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoForma del pocilloTratamiento de superficieVolumen de trabajo (métrico)
436111RedondoPolySorp350 μl
436110RedondoMaxiSorp350 μl
6905TS
también denominado 6905
RedondoMicrofluor 1280 μl
7571RedondoMicroliter 1+280 μl
7572RedondoMicrolite 2+280 μl
7705RedondoMicrofluor 1280 μl
7905RedondoMicrofluor 2280 μl
9502887RedondoAdhesión universal (UB)330 μl
Número de catálogo 436111
Precio (MXN)
-
Forma del pocillo:
Redondo
Tratamiento de superficie:
PolySorp
Volumen de trabajo (métrico):
350 μl

Lleve a cabo inmunoensayos cuantitativos y cualitativos como ELISA, así como ensayos de unión mediante las placas blancas de 96 pocillos para inmunoensayos Thermo Scientific™. Estas placas, que son compatibles con instrumentos comunes, ofrecen resultados óptimos, fiabilidad entre lotes y reproducibilidad entre pocillos.

Características
  • La placa tiene un formato de dimensiones SBS y se adapta al equipo estándar
  • Disponible con pocillos de fondo plano o redondo
  • Selección de tres tipos de superficie para una unión óptima
  • Homogeneidad/reproducibilidad de unión certificadas
  • Selección de superficie:

  • Thermo Scientific™ PolySorp™, Microfluor™ 1, Microlite™ 1+ y Universal Binding (UB) para la adsorción de moléculas hidrófobas.
  • Thermo Scientific™ MaxiSorp™ es hidrófila e ideal para ensayos de tipo sándwich de anticuerpos.
  • Thermo Scientific™ Microfluor 2 y Microlite 2+ son ligeramente hidrófilas y unen una amplia variedad de biomoléculas.
  • Blanco:

  • Ofrece la máxima reflexión
  • Autofluorescencia y autoluminiscencia mínimas
  • Compatible con:

    Tapas para placas Thermo Scientific™ MicroWell™, cinta de sellado y membrana transpirable

    Información sobre pedidos:

    La disponibilidad puede variar según el país.

    Periodo de garantía limitado: este producto está sujeto a todos los requisitos de la garantía y a las exclusiones establecidas por nuestros términos y condiciones de venta. El plazo de garantía comienza a partir de la fecha del envío del producto y finaliza tras noventa (90) días.

    Exención de responsabilidad de la restricción de uso para investigación interna: cualquier restricción impuesta al comprador para utilizar el producto o productos únicamente para fines de investigación interna no se aplica al producto o productos que aparecen en las páginas web asociadas a esta declaración.

    Periodo de garantía limitado: este producto está sujeto a todos los requisitos de la garantía y a las exclusiones establecidas por nuestros términos y condiciones de venta. El plazo de garantía comienza a partir de la fecha del envío del producto y finaliza tras noventa (90) días.
    Especificaciones
    Propiedad de uniónhidrófobos
    Método de detecciónQuimioluminiscencia
    Para utilizar con (aplicación)Fluorescencia y luminiscencia
    TapaCon tapa
    N.º por caja80
    N.° por paquete10
    Envase80 cajas
    Bloqueo de placasNinguno
    Tipo de productoMicroplaca
    Cantidad80/caja
    Molécula dianaLípidos
    Volumen de trabajo (métrico)350 μl
    matriz, red, conjunto8 x 12
    ColorBlanco
    FormatoEstándar
    MaterialPoliestireno
    N.° de pocillos96
    EsterilidadNo estéril
    Tratamiento de superficiePolySorp
    Forma del pocilloRedondo
    Unit SizeCase of 80

    Preguntas frecuentes

    For Clear Flat-Bottom Immuno Nonsterile 96-Well Plates, is the surface treatment solely on the bottom of the well, or is it also applied to the sides?

    For energy treated plates, the entire plate surface receives the energy treatment. The MaxiSorp, PolySorp, MediSorp and MultiSorp plates are energy treated plates. For traditionally treated plates, the well surface is treated up to the listed working volume.

    Are your Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules compatible with all Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates?

    Our Thermo Scientific 8-Well Strip Caps for Immuno Standard Modules were designed to provide a positive seal for flat and round bottom wells of our Nunc MicroWell 96-Well Microplates and Nunc Immuno 96-Well Plates.
    8-Well Strip Caps for Immuno Standard Modules are not compatible with C or V bottom wells of the Nunc Microwell 96-Well Microplates and Nunc Immuno 96-Well Plates.

    For Nunc Immuno plates and modules, what are the advantages of one well geometry type over another? Which types should I use for various applications?

    The following list describes the geometries of wells available for Nunc Immuno-plates and modules:
    - Flat bottom (F): Allows maximum transmission of light. These plates can be read on a monochromatic reader.
    - Round bottom (U): This geometry optimizes washing and coating. These plates can be read using a dual wavelength reader.
    - "C" bottom (C): This design of the well is a combination of both flat and round bottoms. Basically, it is a flat bottomed well with curved edges at the bottom. These plates also can be read using a monochromatic reader combining optimal reading and washing.
    - StarWell: These wells have a modified "C" shape geometry with eight fins strategically placed at the bottom. This feature increases surface area, allowing more molecules to become immobilized which reduces incubation times.

    Which surfaces do you recommend for RIA (radioimmunoassay)?

    The choice of plates or modules will depend on the type of RIA you are planning to perform and specific assay conditions. Nunc provides two different surfaces for immunoassays, PolySorp and MaxiSorp.
    - MaxiSorp surface is highly charged and should be used if the assay requires quantitative measurement of proteins (antibodies) or molecules with polar groups.
    - PolySorp surface should be used if the assay consists of less polar molecules with hydrophobic characteristics.

    Which 96-well Immuno plates or modules do you recommend for various applications?

    The following list offers a brief description of the features of Nunc products and their specific applications:
    - Nunc-Immuno Plates, MaxiSorp surface - These plates are designed for solid phase immuno assays and have a polystyrene surface with high affinity for polar groups and hydrophilic molecules. These 96-well plates are available with flat (F), round (U), or (C) bottom-well designs.
    - Nunc-Immuno Plates, PolySorp surface - These plates have a polystyrene surface which adsorps less polar molecules compared to the MaxiSorp surface and has a high affinity for hydrophobic groups. These 96-well plates are available with flat (F), round (U), or (C) bottom-well designs.
    - Nunc-Immuno Modules - These modules are designed for solid-phase immuno assays. The modules are available in 8-, 12- or 16-well formats with (F), (U), and (C) bottom-well and 8-well BreakApart with (C) bottom-well designs. These different formats allow one to choose the style which is appropriate for their assay design.
    BreakApart Modules and LockWell Modules can be used for radioimmunoassays.
    - Nunc StarWell Immuno Breakable Modules - The 8-well modules feature eight fins on the inner wall of the (C) bottom wells. This design increases the surface area by 50%. The increase in surface area allows more molecules to be immobilized, increasing assay signal. The fin configuration provides shorter diffusion distance to the surface, reducing incubation times.
    - LockWell Immuno Breakable Modules - Each plate consists of 1 x 8 breakable strips. These strips are assembled in a designed frame which locks each well into place by a spring lock. This spring lock design orientates each well at the same horizontal level allowing uniform washing and reading. The LockWell Modules are available with round (U), (C) or StarWell bottom-well designs.
    - Plates and Modules with (CovaLink) Covalent Binding Surfaces: These plates can be used to bind proteins, peptides, DNA or carbohydrates. Covalent linkage occurs via secondary amine group. This allows a specific orientation and provides improved stability compared to passive adsorption due to chemical binding between molecules. Binding of molecules on PolySorp and MaxiSorp surfaces is obtained by passive adsorption. CovaLink is a surface grafted with secondary amino groups (<NH) which serves as a bridge for covalent coupling. The covalent binding can immobilize small molecules such as biotin or peptides which may otherwise bind weakly by physical adsorption and facilitate the recognition by detection molecule.
    - Nunc FluoroNunc/LumiNunc 96-Well Plates: These plates are optimized for IFMA (Immunofluorometric Assays) or FIA (Fluorometric Immuno Assays). The transparent polystyrene plates give a low background fluorescence and are optimal where a read-through system is used. The white plates/modules provide maximum reflection of fluorescence signal while maintaining low background. The white plates/modules are often used for epifluorescence reading. Black modules reduce background fluorescence and minimize back-scatter light which is often encountered in epifluorescence.