SMART Digest RNase Columns
SMART Digest RNase Columns
Thermo Scientific™

SMART Digest RNase Columns

Thermo Scientific SMART Digest™ RNase Columns provide simple, fast and highly reproducible digestion of ribonucleic acid (RNA) to enable oligonucleotide mapping and quantitation.

Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoEnzima
60140-101ARNasa T1
60140-102ARNasa A
Número de catálogo 60140-101
Precio (MXN)
-
Enzima:
ARNasa T1

Thermo Scientific SMART Digest Immobilized Ribonucleases (Rnases) Columns are designed using the same proven technology as the Thermo Scientific SMART Digest Rnase kits to provide simple, fast and highly reproducible digestion of ribonucleic acid (RNA) in a flow through format.

Obtain high-quality analytical results from mRNA digestions using SMART Digest RNase columns. A significant advance in sample preparation for oligonucleotide mapping, the columns provide fast, simple digestion with high levels of reproducibility, RNase columns use immobilized ribonucleases which allow control of partial digestion to produce required fragments of ideal length for sequencing by HRAM-MS.

Easy and simple

  • Simple process allows control of digestion time ensuring required fragment length for comprehensive mRNA sequencing by HRAM MS
  • Single nuclease digestion allows full characterization of mRNA

Reliable results

  • Increased reproducibility over existing protocols
  • Higher data confidence
  • No nuclease contamination of the analytical column

RNase columns are available with two enzyme specificities:

  • RNase T1 is an endoribonuclease that specifically degrades single-stranded RNA at G residues
  • RNase A is an endoribonuclease that specifically degrades single-stranded RNA at C and U residues
Especificaciones
Formato de columnaImmobilized enzyme
Tipo de columnaImmobilized enzyme in PEEK cartridge
DescripciónSMART Digest RNase T1 column
Diámetro2.1 mm
Caudal10 to 500 μL/min
Para utilizar con (aplicación)Oligionucleotide Mapping
Longitud30 mm
Presión máxima2500 psi (170 bar)
Compatibilidad de fase móvilAmmonium acetate or Tris without saline
Intervalo de temperatura de funcionamiento20 °C to 50°C
Material de embalajeHydrophilic/coated DVB
Tamaño de partículas˜20 μm
Tamaño de poro> 1000Å
Estabilidad3 years
Fase estacionariaImmobilized enzyme
Temperatura de almacenamiento4 °C for extended period of time (refrigerate in Tris without Saline)
TécnicaBioLC
Peso8 g
CleavageDegrades single-stranded RNA at G residues
EnzimaARNasa T1
TipoSMART Digest RNase T1 column
pH7 to 8.5
Unit SizeEach