Estreptavidina T1 Dynabeads™ MyOne™
Estreptavidina T1 Dynabeads™ MyOne™
Invitrogen™

Estreptavidina T1 Dynabeads™ MyOne™

La estreptavidina T1 Dynabeads MyOne es el referente en el aislamiento y la manipulación de ácidos nucleicos biotinilados, anticuerpos uMás información
Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoTipo de productoCantidad
65601Dynabeads™ MyOne™ Streptavidin T12 mL
65001Dynabeads™ MyOne™ Streptavidin C12 mL
65002Dynabeads™ MyOne™ Streptavidin C110 mL
65604DDynabeads™ MyOne™ Streptavidin T150 mL
65602Dynabeads™ MyOne™ Streptavidin T110 mL
65605DDynabeads™ Streptavidin for Target Enrichment2 mL
65606DDynabeads™ Streptavidin for Target Enrichment10 mL
65607DDynabeads™ Streptavidin for Target Enrichment50 mL
11205DDynabeads™ M-280 Streptavidin2 mL
11206DDynabeads™ M-280 Streptavidin10 mL
60210Dynabeads™ M-280 Streptavidin100 mL
65305Dynabeads™ M-270 Streptavidin2 mL
65306Dynabeads™ M-270 Streptavidin10 mL
60101Dynabeads™ kilobaseBINDER™ Kit200 Isolations
65801DDynabeads™ Streptavidin Trial Kit4 x 1 mL
Número de catálogo 65601
Precio (MXN)
-
Tipo de producto:
Dynabeads™ MyOne™ Streptavidin T1
Cantidad:
2 mL

La estreptavidina T1 Dynabeads MyOne es el referente en el aislamiento y la manipulación de ácidos nucleicos biotinilados, anticuerpos u otros ligandos y objetivos biotinilados. La elevada afinidad de unión de la interacción entre estreptavidina y biotina (Kd = 10-15) se utiliza en un gran número de aplicaciones. Ventajas y características:

• Aislamiento rápido y directo de cualquier molécula biotinilada
• Protocolos flexibles con cinética de reacción de fase líquida suave y eficaz
• Microesferas de baja carga y neutras, óptimas para la unión de proteínas, péptidos y anticuerpos
• Su pequeño y uniforme tamaño ofrece una gran área de superficie por mg de microesferas y la consecuente gran capacidad para la molécula diana
• Baja tasa de sedimentación con un alto contenido de hierro, lo que garantiza una rápida separación magnética
• Protocolos biomagnéticos que se adaptan fácilmente a las plataformas automatizadas
• Alta reproducibilidad entre lotes que garantiza unos resultados uniformes en la aplicación

Acerca de la estreptavidina Dynabeads MyOne T1
Estas microesferas uniformes y superparamagnéticas poseen un diámetro de 1 μm, con una monocapa (y no una multicapa) de estreptavidina recombinante unida covalentemente a la superficie y bloqueada con BSA. La monocapa de estreptavidina hace que la gran mayoría de los sitios de unión de biotina estén disponibles estéricamente para la unión, no solo de biotina libre, sino también de ligandos y objetivos biotinilados. Las microesferas muestran una rápida cinética de reacción en fase líquida. Su superficie definida y específica permite disfrutar de una captura, separación y posterior manipulación de gran eficacia. La monocapa de estreptavidina garantiza unas fugas insignificantes, mientras que la ausencia de exceso de estreptavidina adsorbida garantiza la uniformidad de los lotes y la reproducibilidad de los resultados. Las microesferas Dynabeads MyOne de 1 μm tienen una gran superficie, una alta capacidad, una eficiente atracción magnética y una lenta tasa de sedimentación durante la incubación. Diseñados a medida para su uso en protocolos automatizados en los que un alto rendimiento es crucial.

Aplicaciones
En los últimos 15 años, las Dynabeads acopladas con estreptavidina se han empleado y citado para una gran variedad de aplicaciones. Entre las aplicaciones clave se incluyen la preparación de plantillas de ADN de una sola cadena, aislamiento de proteínas de unión de ARN y ADN, inmovilización de grandes fragmentos de ADN, purificación de productos de secuenciación y captura específica de ácidos nucleicos. Fácilmente adaptable a procesos automatizados. Dynabeads se emplea rutinariamente en más de 25.000 instrumentos de IVD en todo el mundo.

Capacidad de unión
El tamaño de la molécula y el procedimiento de biotinilación afectarán a la capacidad de unión. La capacidad depende también de la disponibilidad estérica y la interacción de la carga entre microesferas y moléculas y moléculas entre sí. Hay dos o tres sitios de unión de biotina disponibles para cada molécula de estreptavidina en la superficie de la microesfera después de la inmovilización. 1 mg de estreptavidina Dynabeads MyOne T1 normalmente une:

• 950–1500 pmol sin biotina
• ∼20 μg de IgG biotinilada
• ∼400 pmol de péptidos biotinilados
• ∼20 μg de ADNbc
• ∼400 pmol de oligonucleótidos de cadena simple

Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.

Especificaciones
Tipo de esferaMagnetic polystyrene-based beads covalently coupled with recombinant Streptavidin
Propiedad de unión950-1500 pmoles free biotin/mg beads
Certificaciones/conformidadISO9001 and ISO13485
Concentración10 mg/mL
Diámetro (métrico)1 μm (CV < 5%)
Para utilizar con (aplicación)Immunoassays, IP, ChIP, RIP, cell isolations, or DNA isolation for downstream amplification reactions or NGS, requiring high sensitivity, rapid target capture with compatibility with subsequent enzymatic reactions
Para utilizar con (equipo)KingFisher™ Sample Purification System, DynaMag™ magnets
Compatibilidad de alto rendimientoHigh-throughput Compatible
Línea de productosDynabeads
Tipo de productoDynabeads™ MyOne™ Streptavidin T1
Cantidad2 mL
Estado normativoFor Research Use Only
Duración de almacenamiento48 months from date of manufacture
Condiciones de envíoAmbient Temperature
Funcionalidad de superficieTosylactivated hydrophobic surface blocked with BSA
FormatoBeads in Suspension
Isolation TechnologyMagnetic Bead
Unit SizeEach
Contenido y almacenamiento
Dynabeads MyOne Streptavidin T1 are supplied in PBS, pH 7.4, with 0.1% BSA and 0.02% NaN3 . Store at 2–8°C.

Preguntas frecuentes

Can Dynabeads Streptavidin magnetic beads be boiled?

We do not recommend this as streptavidin becomes hydrophobic and aggregates during denaturation.

My Dynabeads magnetic beads are not pelleting well with the magnet. Do you have any suggestions for me?

Please review the following possibilities for why your Dynabeads magnetic beads are not pelleting:

- The solution is too viscous.
- The beads have formed aggregates because of protein-protein interaction.

Try these suggestions: - Increase separation time (leave tub on magnet for 2-5 minutes)
- Add DNase I to the lysate (~0.01 mg/mL)
- Increase the Tween 20 concentration to ~0.05% of the binding and/or washing buffer.
- Add up to 20 mM beta-merecaptoethanol to the binding and/or wash buffers.

Find additional tips, troubleshooting help, and resources within our Dynabeads Nucleic Acid Purification Support Center.

Which streptavidin-conjugated Dynabeads magnetic beads are the right beads for my application?

Which product to choose depends on the properties of your sample, the buffers and solutions applied, as well as the downstream application. In general, all Dynabeads Streptavidin beads can be used in applications involving biotinylated ligands; however, some beads may perform better than others in particular applications due to their characteristics. Dynabeads M-280 Streptavidin beads and Dynabeads MyOne Streptavidin T1 beads are commonly used for protein and nucleic acid applications. Dynabeads M-270 Streptavidin beads and MyOne Streptavidin C1 beads are preferred for nucleic acid diagnostics, specifically with samples that have a high concentration of chaotropic salts, immunoassays involving small biotinylated antigens, and in applications that are not compatible with BSA, as these beads are not blocked with BSA. Dynabeads MyOne Streptavidin beads offer increased binding capacity and slower sedimentation rate, making them ideal for automated applications and when larger amounts of a biotinylated compound or its specific target need to be isolated. Please see the selection guide here ( https://www.thermofisher.com/us/en/home/brands/product-brand/dynal/streptavidin-coupled-dynabeads.html?icid=fr-strep-1).

How do I measure the binding of biotinylated nucleic acid on streptavidin beads?

You can assay the supernatant for unbound nucleic acid to determine the amount of nucleic acid bound to the Dynabeads Streptavidin beads. The concentration of nucleic acids can be checked by measuring the OD or by running them on a gel. Alternatively, the nucleic acids can be labeled radioactively and the concentration measured directly on the beads, or fluorescently and measured in the supernatant.

Can Dynabeads Streptavidin beads be used directly in PCR or real-time PCR reactions?

Our Dynabeads Streptavidin magnetic beads can be used directly in PCR or real-time PCR. However, you would have to empirically optimize the amount of beads to be used per volume of reaction.

Citations & References (4)

Citations & References
Abstract
Quantification of ricin, RCA and comparison of enzymatic activity in 18 Ricinus communis cultivars by isotope dilution mass spectrometry.
Authors:Schieltz DM, McWilliams LG, Kuklenyik Z, Prezioso SM, Carter AJ, Williamson YM, McGrath SC, Morse SA, Barr JR
Journal:
PubMed ID:25576235
'The seeds of the Ricinus communis (Castor bean) plant are the source of the economically important commodity castor oil. Castor seeds also contain the proteins ricin and R. communis agglutinin (RCA), two toxic lectins that are hazardous to human health. Radial immunodiffusion (RID) and the enzyme linked immunosorbent assay (ELISA) ... More
Design and characterization of ebolavirus GP prehairpin intermediate mimics as drug targets.
Authors:Clinton TR, Weinstock MT, Jacobsen MT, Szabo-Fresnais N, Pandya MJ, Whitby FG, Herbert AS, Prugar LI, McKinnon R, Hill CP, Welch BD, Dye JM, Eckert DM, Kay MS
Journal:
PubMed ID:25287718
'Ebolaviruses are highly lethal filoviruses that cause hemorrhagic fever in humans and nonhuman primates. With no approved treatments or preventatives, the development of an anti-ebolavirus therapy to protect against natural infections and potential weaponization is an urgent global health need. Here, we describe the design, biophysical characterization, and validation of ... More
Minimalistic sample preparation strategies for LC-MS quantification of large molecule biopharmaceuticals: a case study highlighting alpha-1 antitrypsin protein.
Authors:Wright K, Dufield D
Journal:
PubMed ID:25157487
Large molecule biotherapeutics pose a distinctive bioanalytical challenge for LC-MS assay development, particularly when optimizing sample enrichment steps. Alpha-1 antitrypsin (AAT) is used as an example for highlighting large-molecule assay-development strategies. ... More
A U1 snRNP-specific assembly pathway reveals the SMN complex as a versatile hub for RNP exchange.
Authors:So BR, Wan L, Zhang Z, Li P, Babiash E, Duan J, Younis I, Dreyfuss G
Journal:Nat Struct Mol Biol
PubMed ID:26828962
Despite equal snRNP stoichiometry in spliceosomes, U1 snRNP (U1) is typically the most abundant vertebrate snRNP. Mechanisms regulating U1 overabundance and snRNP repertoire are unknown. In Sm-core assembly, a key snRNP-biogenesis step mediated by the SMN complex, the snRNA-specific RNA-binding protein (RBP) Gemin5 delivers pre-snRNAs, which join SMN-Gemin2-recruited Sm proteins. ... More