Concentrador de proteínas de PES Pierce™, MWCO de 3 K, de 5 a 20 ml
Concentrador de proteínas de PES Pierce™, MWCO de 3 K, de 5 a 20 ml
El producto real puede variar
Thermo Scientific™

Concentrador de proteínas de PES Pierce™, MWCO de 3 K, de 5 a 20 ml

Los concentradores de proteínas de PES Thermo Scientific™ Pierce™ son dispositivos de ultrafiltración centrífuga desechables con una membrana de polietersulfonaMás información
Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoMWCOCantidadVolumen de muestra
885123 kDa25 concentradores≤ 0,5ml
885143 kDa10 concentradoresDe 2 a 6 ml
885153 kDa24 concentradoresDe 2 a 6 ml
885253 kDa10 concentradoresDe 5 a 20 ml
885263 kDa24 concentradoresDe 5 a 20 ml
885345 kDa4 concentradoresDe 20 a 100 ml
Número de catálogo 88512
Precio (MXN)
-
MWCO:
3 kDa
Cantidad:
25 concentradores
Volumen de muestra:
≤ 0,5ml
Los concentradores de proteínas de PES Thermo Scientific™ Pierce™ son dispositivos de ultrafiltración centrífuga desechables con una membrana de polietersulfona (PES) para la concentración, la desalinización y el intercambio de tampones de muestras biológicas.Este producto tiene un tope de peso molecular (MWCO) de 3K y se puede utilizar para el procesamiento de volúmenes de muestra de 5 a 20 ml.

Características de los concentradores de proteínas de PES Pierce:

•Concentración proteica rápida: puede conseguirse una concentración de la muestra de 10 a 30 veces en un periodo de 5 a 30 minutos para MWCO de 10K (el tiempo puede variar para un producto con un MWCO diferente)
• Excelente recuperación de proteínas: la recuperación de proteínas típica es >90 %
• Versatilidad: concentración de muestras sencillo, diafiltración o intercambio de tampones de muestras biológicas
• Compatibilidad: puede usarse tanto en rotores de ángulo fijo como en rotores de vasos basculantes; recoger y recuperar muestras sin centrifugación inversa

Para facilitar la identificación, el valor de MWCO se graba en el lateral de cada dispositivo.Para facilitar la adición y recuperación de muestras, hay una ventana transparente con graduaciones en el lateral de cada dispositivo, lo que permite la determinación visual del volumen de retención.El diseño vertical de la membrana permite altas velocidades de flujo, baja unión no específica y una agregación proteica insignificante en la membrana; y proporciona resultados fiables y coherentes.

Los concentradores de proteínas de PES Pierce contienen una membrana clasificada para retener moléculas con un peso molecular al menos 2 veces mayor que la clasificación MWCO de la membrana de PES del dispositivo.Una menor recuperación puede ocurrir cuando se usa un concentrador con moléculas más pequeñas que la masa recomendada.La recuperación de proteínas variará dependiendo de la proteína específica de la muestra y de su concentración inicial.Para lograr una recuperación >90 % de la proteína, la concentración mínima de la muestra de proteína debe ser de 0,1 mg/ml.
For Research Use Only. Not for use in diagnostic procedures.
Especificaciones
DescripciónConcentradores de proteínas de PES Pierce™, MWCO de 3000, 0,5 ml
Línea de productosPierce
Diana de purificaciónproteína
Cantidad25 concentradores
Condiciones de envíoTemperatura ambiente
TipoFiltro
Desechables
Tipo de filtroFiltro de membrana
FormatoMicrocentrífuga, columna de centrifugación
MWCO3 kDa
Material (membrana)PES
Volumen de muestra≤ 0,5ml
Unit SizeEach
Contenido y almacenamiento
Almacenar a temperatura ambiente.

Preguntas frecuentes

Besides precipitation with ammonium sulfate, what are some ways I can concentrate my protein sample?

You may remove excess solvent and smaller moieties by centrifugation through a microconcentrator. This will concentrate your protein sample.

(1) Choose microconcentrator tube (available from a variety of commercial suppliers) with a protein cutoff smaller than the molecular weight of the protein in the sample. Check our Pierce Protein Concentrators PES.

(2) Add 1 µL of 20% w/v SDS to a dry microconcentrator tube (if sample does not already contain SDS).

(3) Slowly add sample (a few microliters at a time) to membrane until membrane is completely wet. Centrifuge to near (but not complete) dryness.

(4) If intention is to desalt sample or buffer exchange: Add ~50 µL water to microconcentrator and spin until nearly dry. Repeat buffer exchange. Sample will remain on membrane. Check our Zeba desalting proteins.

(5) Using a new collection tube, invert membrane and spin at low speed (1000 x g) to elute protein from membrane. Add 2X SDS-Sample Buffer containing 10 mM DTT to membrane: vortex, invert and spin. Final volume should be ~20 µL.

Find additional tips, troubleshooting help, and resources within our Protein Dialysis, Desalting, and Concentration Support Center.

Can I autoclave PES protein concentrators?

We do not recommend autoclaving the PES protein concentrators. High temperatures will significantly increase the membrane molecular weight cutoff (MWCO). To sterilize, we recommend using a 70% ethanol solution.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

Can I use PES protein concentrators for desalting and buffer exchange?

Yes, the PES membrane is compatible with desalting and buffer exchange. Protocols for concentrating, desalting, and buffer exchange only are provided in the product manuals.

How do PES protein concentrators work?

The protein concentrator columns have an upper compartment that holds the sample, and a lower compartment. The two compartments are separated by a polyethersulfone (PES) semipermeable membrane. Centrifugation is applied to force solvent through the membrane, leaving a more concentrated sample in the upper chamber. The protein concentrator cassettes also contain a PES membrane and a unique channel design that ensures high optimal flux with no optimization effort. Unlike other systems, the fluid is passed parallel to the filter, rather than being pushed through a membrane perpendicularly, which can clog the filter. For maximum protein recovery in both columns and cassettes, samples should have a molecular weight two-fold greater than the molecular weight cutoff (MWCO) of the concentrator membrane.

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.

What are the different sizes of PES protein concentrators you offer?

Pierce polyethersulfone (PES) protein concentrators are offered in six distinct MWCOs of 3K, 5k, 10K, 30K, 50K, and 100K, and the cassettes are offered in five membrane MWCOs of 3K, 10K, 30K, 50K, and 100K. The columns can process four different sample volumes ranges of 100-500 µL, 2-6 mL, 5-20 mL, and 20-100 mL, while the cassettes can process 0.5-6 L. Please see our selection chart and video found here (https://www.thermofisher.com/us/en/home/life-science/protein-biology/protein-purification-isolation/protein-dialysis-desalting-concentration/protein-concentrators.html).

Find additional tips, troubleshooting help, and resources within our Protein Assays and Analysis Support Center.