LanthaScreen™ TR-FRET ER alpha Competitive Binding Kit
LanthaScreen™ TR-FRET ER alpha Competitive Binding Kit

LanthaScreen™ TR-FRET ER alpha Competitive Binding Kit

El kit de unión competitiva LanthaScreen™ TR-FRET ER alfa proporciona un método sensible y robusto para el cribado analítico masivoMás información
Have Questions?
Número de catálogoCantidad
A15887800 ensayos de 20 μL
Número de catálogo A15887
Precio (MXN)
-
Cantidad:
800 ensayos de 20 μL
El kit de unión competitiva LanthaScreen™ TR-FRET ER alfa proporciona un método sensible y robusto para el cribado analítico masivo de ligandos para el receptor de estrógeno (ER) alfa. El kit utiliza un dominio humano de unión a ligando (LBD) ER alfa marcado con glutatión S-transferasa (GST), un anticuerpo anti-GST marcado con terbio y un ligando ER fluorescente de molécula pequeña (Fluormone™ ES2) en un formato de ensayo homogéneo de mezcla y lectura.

El ensayo de unión competitiva LanthaScreen ER alfa es:

• Listo para su uso tras sacarlo del envase: todos los reactivos incluidos, solo tiene que añadir sus compuestos de prueba
• Compatible con alto rendimiento: ensayos TR-FRET en 1 placa de 384 pocillos
• Práctico: componentes disponibles a granel para las necesidades de detección más grandes
Para uso exclusivo en investigación. No apto para uso en procedimientos diagnósticos.
Especificaciones
Para utilizar con (aplicación)Ensayo de unión competitiva, ensayo de receptores nucleares
Línea de productosLanthaScreen
Cantidad800 ensayos de 20 μL
TipoKit de unión competitiva TR-FRET ER alpha
Unit SizeEach
Contenido y almacenamiento
1 tubo de proteína recombinante de dominio de unión de ligando ER alfa (almacenar entre -68 y -85 °C)
1 tubo de Fluormone ES2 (almacenar entre -5 y -30 °C)
2 frascos de tampón NR (almacenar entre -5 y -30 °C)
1 tubo de Tb-Anti-GST Ab (almacenar entre -5 y -30 °C)
1 tubo de DTT (almacenar entre -5 y -30 °C)

Preguntas frecuentes

I'm using the TaqMan hPSC Scorecard Panel. What web browsers are compatible with the hPSC Scorecard Analysis Software?

The hPSC Scorecard Analysis Software is accessible through Thermo Fisher Connect and is compatible with the following web browsers:

  • Safari
  • Google Chrome


Find additional tips, troubleshooting help, and resources within our Real-Time PCR and Digital PCR Applications Support Center

How does the LanthaScreen technology compare to other TR-FRET assay formats?

We performed a comparison between the LanthaScreen assay and other commercially available TR-FRET assays from 2 different suppliers for the PKC kinase target. Our data revealed that the assays performed comparably, but that the LanthaScreen assay was simpler to optimize and contained fewer components that required optimization. The LanthaScreen assay is a two component system, whereas the other assay formats utilize a trimolecular mechanism which is more time consuming to optimize and has added costs.

For my kinase assay, can I pre-mix the Tb-Ab and EDTA so that I can stop the kinase assay and begin detection with a single reagent addition?

Yes, this is possible depending on the concentrations of reagents used and the time for which they are mixed. We recommend developing and optimizing the assay by using separate reagent additions, because this method will work under the widest range of conditions. Once the assay is optimized, the performance of the assay using pre-mixed antibody and EDTA can be evaluated. We have successfully developed robust assays in which the antibody and EDTA were pre-mixed and then stored overnight at 4 degrees C prior to use the following day. A loss of signal intensity was observed in this case, however, by using the ratiometric readout, this effect was minimal.

Are the LanthaScreen reagents stable to interference from Mg2+, Mn2+, and EDTA?

The chelate is completely stable to Mg2+. The amount of Mn2+ or EDTA that the chelate can tolerate depends largely on how long they are mixed together and the combination of additives used in the reaction. If a reaction requires either Mg2+ or Mn2+ for activation, it is best to stop the reaction by adding an equimolar amount (or slight excess) of EDTA to chelate the metal ions present. This will then essentially eliminate any interference on the terbium chelate by EDTA or Mn2+. Regardless, when LanthaScreen assays are performed using a ratiometric readout (division of the acceptor signal by the donor signal), any interference caused by Mn2+ or EDTA is largely cancelled out.

What is the optimal and/or maximum distance for a Tb-fluorescein pair?

The Förster radius, the distance at which energy transfer efficiency is half-maximal, is around 50-angstroms for the terbiumÆ fluorescein pair. However, the Förster radius does not give a complete indication of energy transfer efficiency when using long lifetime fluorophores such as terbium chelates. When using terbium chelates, energy transfer efficiency is determined by the distance of closest approach between the donor and acceptor during the excited state lifetime of the donor. In many assay systems, such as those designed using antibodies or peptides, there is a large degree of conformational freedom that allows the donor and acceptor to approach one another, effectively enhancing the FRET signal. Additionally, it is important to note that as the donor/acceptor pair approach one another and the efficiency of energy transfer increases, the fluorescent lifetime decreases to a comparable extent. From a practical standpoint, this means that when energy transfer is extremely efficient, FRET cannot be measured in time-resolved mode (because the energy transfer is complete before the measurement is made). This is another reason why TR-FRET assays based around terbium-labeled antibodies or streptavidin perform so well, because there exist a range of donor/acceptor distances, several of which are optimal for measuring FRET.