NanoDrop™ Reagents
NanoDrop™ Reagents
Thermo Scientific™

NanoDrop™ Reagents

Certified standards for verifying instrument performance to factory specifications are available separately.
Have Questions?
Cambiar vistabuttonViewtableView
Número de catálogoTipo
CHEM-CF-8Kit de comprobación de calibración
CHEM-CF-1Solución acuosa de dicromato de potasio (K2Cr207)
CHEM-PR1-KITKit acondicionador NanoDrop PR-1
CHEM-PV-1Verificación de rendimiento PV-1
Número de catálogo CHEM-CF-8
Precio (MXN)
-
Tipo:
Kit de comprobación de calibración
Certified standards for verifying instrument performance to factory specifications are available separately.

CHEM-PV-1 - PV-1 Performance Verification Solution

For use with NanoDrop Ultra Spectrophotometers and Fluorometers, NanoDrop One/OneC and NanoDrop Lite Plus
Solution with certified absorbance values.
Use to create a record of correct photometric performance.
Intended for single use only.
 

CHEM-PV-8 - PV-8 Performance Verification Kit

For use with NanoDrop Eight
Solution with certified absorbance values.
Use to create a record of correct photometric performance.
Intended for single use only.
 

CHEM-CF-1 - CF-1 Calibration Fluid

For use with NanoDrop 1000, NanoDrop 2000/2000c, NanoDrop Lite
Solution with certified absorbance values.
Use to create a record of correct photometric performance.
Intended for single use only.
 

CHEM-CF-8 - CF-8 Calibration Check Kit

For use with NanoDrop 8000
Solution with certified absorbance values.
Use to create a record of correct photometric performance.
Intended for single use only.
 

CHEM-PR1-KIT - PR-1 Reconditioning Kit

For use with all NanoDrop models
This kit is useful for reconditioning the sample measurement pedestals to a hydrophobic state if they become “unconditioned” (see user manual for more information). The PR-1 kit consists of a small screw cap vial of specially formulated compound and a supply of 25 convenient applicators.

Especificaciones
Para utilizar con (equipo)Espectrofotómetro NanoDrop 8000
Incluye2 ampollas CF-1; tira de 8 tubos para PCR.
EnvaseAmpollas de vidrio rompibles de 0,5 ml.
TipoKit de comprobación de calibración
Unit SizeEach

Preguntas frecuentes

How often should I check the calibration of my NanoDrop 8000 Spectrophotometer?

We recommend you check the calibration of your NanoDrop 8000 Spectrophotometer every 6 months using the NanoDrop CF-8 Calibration Check Kit.

How do I check the calibration of my NanoDrop 8000 Spectrophotometer? Do I need to calibrate it?

You can easily check the calibration of your NanoDrop 8000 Spectrophotometer by using the NanoDrop CF-8 Calibration Check Kit, which contains two CF-1 Ampules and two 8-well PCR tube strips. The CF-8 kit is available from the Thermo Fisher website (Cat. No. CHEM-CF-8).
If re-calibration is ever needed, it is performed by a trained service technician. Due to the precise nature of the NanoDrop instrument design, these spectrophotometers rarely require re-calibration.