Disco Oxoid™ Vibrios O129
Disco Oxoid™ Vibrios O129
El producto real puede variar
Thermo Scientific™

Disco Oxoid™ Vibrios O129

Differentiate Vibrios from other Gram-negative rods using these diagnostic discs.
Have Questions?
Número de catálogoConcentración
DD0015T150 μg
Número de catálogo DD0015T
Precio (MXN)
-
Concentración:
150 μg

Differentiate vibrios from other Gram-negative rods using Thermo Scientific™ Oxoid™ 0129 Discs. The test exploits the sensitivity of vibrios to the vibrio static agent 0129 (2,4-Diamino-6,7-di-iso-propylpteridine phosphate)1. 0129 Discs are of great value in differentiating vibrios from other Gram-negative rods and particularly from aeromonads, which are characteristically resistant to 0129. The degree of sensitivity of vibrios to 0129 can also be used as a diagnostic feature in differentiation of Vibrio species.

Vibrio is a genus of comma shaped Gram-negative bacteria responsible for number of foodborne infections often associated with undercooked seafood. Use 0129 Discs as a rapid and simple method for differentiation of vibrios from other Gram-negative rods.

  • Rapid Results
  • Simple and ready-to-use in cartridge format
  • Can be used in differentiation of Vibrio

The degree of sensitivity of vibrios to 0129 can also be used as a diagnostic feature in differentiation of Vibrio species.

  1. parahaemolyticus – (10μg) Resistant – (150μg) Sensitive
  2. alginolyticus – (10μg) Resistant – (150μg) Sensitive
  3. fluvialis – (10μg) Resistant – (150μg) Sensitive
  4. furnissii – (10μg) Resistant – (150μg) Sensitive

Aeromonas – (10μg) Resistant – (150μg) Resistant

  1. cholerae 0139 – (10μg) Resistant – (150μg) Resistant
  2. cholerae 01 – (10μg) Resistant – (150μg) Resistant
  3. cholerae – (10μg) Sensitive – (150μg) Sensitive
  4. cholera spp – (10μg) Sensitive – (150μg) Sensitive
  5. vulnificus – (10μg) Sensitive – (150μg) Sensitive

Negative 0129 tests must be interpreted with caution. Strains of Vibrio cholerae resistant to 0129 and trimethoprim have been reported2. Both plasmids and transposons appear to be responsible3.

Specialised sensitivity testing media which contain low levels of sodium chloride should not be used as these may give poor growth of halophilic vibrios and may also give false positive results with Enterobacteriaceae4. Nutrient Agar CM0003 can be recommended for such testing.

Not all products are available for sale in all territories. Please inquire.

Remel™ and Oxoid™ products are now part of the Thermo Scientific brand.


Para uso diagnóstico in vitro
For In Vitro Diagnostic Use.  

Referencias generales:

  1. Shewan J. M. and Hodgkiss W. (1954) Nature 173.208-209.
  2. The Lancet, August 8th 1992, 340.366-367.
  3. Gerbaud G., Dodin A., Goldstein F. and Courvain P. (1985) Ann.Inst.Past./Microbiol.136B.265-273.
  4. Furniss A. L., Lee J.V. and Donovan T.J.(1978) The Vibrios.Public Health Laboratory Service, Monograph Series.Number 11
Especificaciones
Concentración150 μg
FormatoDisk, Cartucho
Tipo de empaquetado50 discos/cartucho
Cantidad150 μg
TipoDisco Vibrios O129
Analitos detectablesVibriones y otros bacilos gramnegativos
Unit SizeEach
Contenido y almacenamiento
De 2 °C a 8 °C