TurboFlow™ Columns for Automated Online LC-MS Sample Cleanup
TurboFlow™ Columns for Automated Online LC-MS Sample Cleanup
Actual product may vary
Thermo Scientific™

TurboFlow™ Columns for Automated Online LC-MS Sample Cleanup

Automate online matrix cleanup of complex matrices on your LC-MS to eliminate manual cleanup and improve productivity and certainty of results.

Have Questions?
Change viewbuttonViewtableView
Catalog NumberDescriptionColumn Phase
CH-953244TurboFlow Cyclone C18 Column 1 x 50 mmSilica based reversed phase
CH-952434TurboFlow Cyclone Column 1 x 50 mmPolymer based
CH-952813TurboFlow Cyclone MCX Column 1 x 50 mmPolymer based phase mixed cation exchange
CH-952979TurboFlow Cyclone MAX Column 1 x 50 mmPolymer based mixed mode anion exchange
CH-953275TurboFlow Cyclone C18-P Column 1 x 50 mmSilica based reversed phase
CH-953276TurboFlow Cyclone C8 Column 1 x 50 mmSilica based reversed phase
CH-953277TurboFlow Cyclone Fluro Column 1 x 50 mmSilica based fluorinated alkyl
CH-953279TurboFlow Cyclone C2 Column 1 x 50 mmSilica based reversed phase
CH-953280TurboFlow Cyclone C18 Column 0.5 x 50 mmSilica based reversed phase
CH-953281TurboFlow Cyclone C18-P Column 0.5 x 50 mmSilica based reversed phase
CH-953282TurboFlow Cyclone C8 Column 0.5 x 50 mmSilica based reversed phase
CH-953283TurboFlow Cyclone Fluro Column 0.5 x 50 mmSilica based fluorinated alkyl
CH-953285TurboFlow Cyclone C2 Column 0.5 x 50 mmSilica based reversed phase
CH-953286TurboFlow Cyclone MAX Column 0.5 x 50 mmPolymer based mixed mode anion exchange
CH-953287TurboFlow Cyclone MCX Column 0.5 x 50 mmPolymer based phase mixed cation exchange
CH-953288TurboFlow Cyclone Column 0.5 x 50 mmPolymer based
CH-953289TurboFlow Cyclone-P Column 0.5 x 50 mmPolymer based
CH-953456TurboFlow Cyclone MCX-2 Column 1 x 50 mmPolymer based phase mixed cation exchange
CH-953457TurboFlow Cyclone MCX-2 Column 0.5 x 50 mmPolymer based phase mixed cation exchange
19 Options
Catalog number CH-953244
Price (TWD)/ Each
-
Description:
TurboFlow Cyclone C18 Column 1 x 50 mm
Column Phase:
Silica based reversed phase

Use Thermo Scientific™ TurboFlow™ Columns for automated online matrix cleanup of complex matrices analyzed on the Thermo Scientific™ Aria™ and Transcend™ TLX. Placed before the analytical column, TurboFlow sample cleanup columns enable direct injection of complex matrices such as food, plasma, urine, and other biological matrices into the mass spectrometry (MS) system without prior sample pretreatment. The patented TurboFlow column design retains compounds of interest for subsequent analysis, while complex matrices quickly and completely elute to waste.

Improve productivity
TurboFlow columns automate the many tasks traditionally performed manually, thereby eliminating the many error-prone manual steps performed for matrix cleanup that cause variability in data. As a result, this automated sample cleanup technique can improve productivity and certainty in test results.

Minimize ion supression, produce clean sample extracts:

  • Minimize sample preparation – simplifies complex sample preparation protocols
  • Reduce ion suppression – achieves better data quality
  • Simplify method development – uses the same method for different matrices
  • Save time – injects samples directly into LC-MS system
Specifications
Column PhaseSilica based reversed phase
DescriptionTurboFlow Cyclone C18 Column 1 x 50 mm
For Use With (Application)Pharmaceuticals; Fatty Acids. Most Retentive of The Alkyl-Bonded Phases for Non-Polar Solutes
For Use With (Equipment)Transcend and Aria TLX Systems
Product LineTurboFlow
SorbentC18
TypeTurboFlow XL Column
Length (Metric)50 mm
Diameter (Metric) Inner1 mm
Unit SizeEach