Thermo Scientific™

Dionex™ EWP Electrolytic Water Purifier

產品號碼: 072629
Thermo Scientific™

Dionex™ EWP Electrolytic Water Purifier

產品號碼: 072629
Use the Thermo Scientific™ Dionex™ EWP Electrolytic Water Purifier to generate ultrapure water for sample and standard transfers in trace anion and cation ion chromatography (IC) applications. This device purifies transfer water to practically eliminate contamination and provide the extremely low background levels required for trace analysis. This dual-chamber electrolytic device is available in anion and cation versions.
 
產品號碼
072629
Unit Size
Each
Description
Electrolytic Water Purifier Kit for Anion Analysis
價格 (TWD)
完整規格
For Use With (Equipment)ICS-2100 and ICS-5000+ Systems
TypeElectrolytic Water Purifier Kit
Flow Rate0.1 to 3 mL/min.
PressureMinimum feed pressure: 34.5 kPa (5 psi) Maximum back pressure: 517.1 kPa (75 psi)
OperationGenerates ultrapure water for sample and standard transfers in trace anion ion chromatography (IC) applications.
DescriptionElectrolytic Water Purifier Kit for Anion Analysis
Unit SizeEach
產品號碼
Unit Size
Each
Description
Electrolytic Water Purifier Replacement Unit (EWP only) for Anion Analysis
價格 (TWD)
完整規格
For Use With (Equipment)ICS-2100 and ICS-5000+ Systems
TypeElectrolytic Water Purifier Replacement Unit
Flow Rate0.1 to 3 mL/min.
PressureMinimum feed pressure: 34.5 kPa (5 psi) Maximum back pressure: 517.1 kPa (75 psi)
OperationGenerates ultrapure water for sample and standard transfers in trace anion ion chromatography (IC) applications.
DescriptionElectrolytic Water Purifier Replacement Unit (EWP only) for Anion Analysis
Unit SizeEach
產品號碼
Unit Size
Each
Description
Electrolytic Water Purifier Replacement Unit (EWP only) for Cation Analysis
價格 (TWD)
完整規格
For Use With (Equipment)ICS-2100 and ICS-5000+ Systems
TypeElectrolytic Water Purifier Replacement Unit
Flow Rate0.1 to 3 mL/min.
PressureMinimum feed pressure: 34.5 kPa (5 psi) Maximum back pressure: 517.1 kPa (75 psi)
OperationGenerates ultrapure water for sample and standard transfers in trace cation ion chromatography (IC) applications.
DescriptionElectrolytic Water Purifier Replacement Unit (EWP only) for Cation Analysis
Unit SizeEach
產品號碼
Unit Size
Each
Description
Electrolytic Water Purifier Kit for Cation Analysis
價格 (TWD)
完整規格
For Use With (Equipment)ICS-2100 and ICS-5000+ Systems
TypeElectrolytic Water Purifier Kit
Flow Rate0.1 to 3 mL/min.
PressureMinimum feed pressure: 34.5 kPa (5 psi) Maximum back pressure: 517.1 kPa (75 psi)
OperationGenerates ultrapure water for sample and standard transfers in trace cation ion chromatography (IC) applications.
DescriptionElectrolytic Water Purifier Kit for Cation Analysis
Unit SizeEach
顯示 4 項,共 4 項
產品號碼規格Unit SizeDescription價格 (TWD)
072629完整規格
EachElectrolytic Water Purifier Kit for Anion Analysis申請報價
For Use With (Equipment)ICS-2100 and ICS-5000+ Systems
TypeElectrolytic Water Purifier Kit
Flow Rate0.1 to 3 mL/min.
PressureMinimum feed pressure: 34.5 kPa (5 psi) Maximum back pressure: 517.1 kPa (75 psi)
OperationGenerates ultrapure water for sample and standard transfers in trace anion ion chromatography (IC) applications.
DescriptionElectrolytic Water Purifier Kit for Anion Analysis
Unit SizeEach
071553完整規格
EachElectrolytic Water Purifier Replacement Unit (EWP only) for Anion Analysis申請報價
For Use With (Equipment)ICS-2100 and ICS-5000+ Systems
TypeElectrolytic Water Purifier Replacement Unit
Flow Rate0.1 to 3 mL/min.
PressureMinimum feed pressure: 34.5 kPa (5 psi) Maximum back pressure: 517.1 kPa (75 psi)
OperationGenerates ultrapure water for sample and standard transfers in trace anion ion chromatography (IC) applications.
DescriptionElectrolytic Water Purifier Replacement Unit (EWP only) for Anion Analysis
Unit SizeEach
071859完整規格
EachElectrolytic Water Purifier Replacement Unit (EWP only) for Cation Analysis申請報價
For Use With (Equipment)ICS-2100 and ICS-5000+ Systems
TypeElectrolytic Water Purifier Replacement Unit
Flow Rate0.1 to 3 mL/min.
PressureMinimum feed pressure: 34.5 kPa (5 psi) Maximum back pressure: 517.1 kPa (75 psi)
OperationGenerates ultrapure water for sample and standard transfers in trace cation ion chromatography (IC) applications.
DescriptionElectrolytic Water Purifier Replacement Unit (EWP only) for Cation Analysis
Unit SizeEach
072630完整規格
EachElectrolytic Water Purifier Kit for Cation Analysis申請報價
For Use With (Equipment)ICS-2100 and ICS-5000+ Systems
TypeElectrolytic Water Purifier Kit
Flow Rate0.1 to 3 mL/min.
PressureMinimum feed pressure: 34.5 kPa (5 psi) Maximum back pressure: 517.1 kPa (75 psi)
OperationGenerates ultrapure water for sample and standard transfers in trace cation ion chromatography (IC) applications.
DescriptionElectrolytic Water Purifier Kit for Cation Analysis
Unit SizeEach
顯示 4 項,共 4 項

Effluent from the conductivity cell supplies feed water for the Electrolytic Water Purifier. Water passing through the Electrolytic Water Purifier's main purification chamber exits the device free of ionic contamination, including carbonate. This device is used in AutoPrep mode, which enhances simplicity by eliminating the need for an auxiliary loading pump and removing potential contamination from the pump.

The Electrolytic Water Purifier is powered by either the:

  • Standard auxiliary power supply on the Thermo Scientific™ Dionex™ ICS-2100 system, or the
  • Thermo Scientific™ Dionex™ CR-TC Continuously Regenerated Trap Column power supply on the Dionex ICS-5000+ Eluent Generator (EG) module.

The Electrolytic Water Purifier is one of several examples of Reagent-Free™ Ion Chromatography - Electrolytic Sample Preparation (RFIC™-ESP™).

圖表

文件與下載

證書

    常見問答集 (常見問題)

    引用資料與參考文獻

    Search citations by name, author, journal title or abstract text