Thermo Scientific™

iConnect™ Flame Photometric Detector (FPD) for TRACE™ 1300 and 1600 Series GC

產品號碼: 19070096
Thermo Scientific™

iConnect™ Flame Photometric Detector (FPD) for TRACE™ 1300 and 1600 Series GC

產品號碼: 19070096

Enjoy excellent sensitivity and response stability for the most demanding sulfur applications, as well as for phosphorous or tin determinations. The Thermo Scientific™ iConnect™ Flame Photometric Detector (FPD) has an extended operating temperature range and dual wavelength capabilities to further expand its applicability. This detector is for use with Thermo Scientific™ TRACE™ 1300 and 1600 Series GC systems.

 
產品號碼
19070096
Unit Size
Each
Description
iConnect Flame Photometric Detector (FPD) module
For Use With (Equipment)
TRACE 1300 and 1600 Series Gas Chromatographs
價格 (TWD)
完整規格
TypeiConnect Flame Photometric Detector
DescriptioniConnect Flame Photometric Detector (FPD) module
For Use With (Equipment)TRACE 1300 and 1600 Series Gas Chromatographs
Unit SizeEach
顯示 1 項,共 1 項
產品號碼規格Unit SizeDescriptionFor Use With (Equipment)價格 (TWD)
19070096完整規格
EachiConnect Flame Photometric Detector (FPD) moduleTRACE 1300 and 1600 Series Gas Chromatographs申請報價
TypeiConnect Flame Photometric Detector
DescriptioniConnect Flame Photometric Detector (FPD) module
For Use With (Equipment)TRACE 1300 and 1600 Series Gas Chromatographs
Unit SizeEach
顯示 1 項,共 1 項

Reduce downtime, simplify maintenance, and enhance GC performance

iConnect injectors and detectors redefine GC and GC-MS flexibility and usability. In two minutes, without training or tools, you can replace these modules to:

  • Reconfigure your system for a specific workflow or method
  • Perform maintenance off-line, maintaining instrument uptime
  • Make better use of resources by sharing injectors and detectors between TRACE GC systems

The iConnect Flame Photometric Detector provides a specific response towards sulphur-, phosphorus-, or tin- containing compounds depending on the installed optical filter, and is easily interchangeable with other iConnect modules. A Dual-Tube configuration is possible by mounting two different optical filters for simultaneous specific detection.

Specifications:

  • MDL: 100 fg P/s and 5 pg S/s (Methyl Parathion)
  • Dynamic range: 10E4 for P, >10E3 for S (quadratic response)
  • Selectivity: P/C = 10E6 :1, and S/C = 10E6 :1
  • Maximum temperature: 450 °C
  • Acquisition rate up to 300 Hz

圖表