Plate Septa, 96 well
Product Image
Applied Biosystems™

Plate Septa, 96 well

These are septa for use with the 3730, 3730xl, 3130xl, and 3130, instruments.Use with:310 Running Buffer (10X), 3100/3100-Avant™ Genetic Analyzer深入閱讀
Have Questions?
產品號碼Quantity
431593320 each
產品號碼 4315933
價格 (TWD)
23,600.00
Online offer
Ends: 31-Mar-2026
29,400.00
您節省 5,800.00 (20%)
Each
新增至購物車
Quantity:
20 each
價格 (TWD)
23,600.00
Online offer
Ends: 31-Mar-2026
29,400.00
您節省 5,800.00 (20%)
Each
新增至購物車
These are septa for use with the 3730, 3730xl, 3130xl, and 3130, instruments.

Use with:
310 Running Buffer (10X), 3100/3100-Avant™ Genetic Analyzer Autosampler Plate Kit, 96-well, 3130/3100-Avant™ Genetic Analyzer Capillary Array (36 cm), 3130xl/3100 Genetic Analyzer Capillary Array (36 cm), 3130xl/3100 Genetic Analyzer Capillary Array (50 cm), 3730 Running Buffer (10X), 5.0 mL Glass Syringe (polymer reserve syringe), 96-Well Plate Base, 96-Well Plate Retainer, Hi-Di™ Formamide, MicroAmp™ Optical 96-Well Reaction Plate, MicroAmp™ Optical 96-Well Reaction Plate with Barcode, POP-4™ Polymer for 3100/3100-Avant™ Genetic Analyzers, POP-4™ Polymer for 3130/3130xl Genetic Analyzers, POP-4™ Polymer for 3130/3130xl Genetic Analyzers, POP-7™ Polymer for 3130/3130xl Genetic Analyzers, POP-7™ Polymer for 3130/3130xl Genetic Analyzers, Reservoir Septa
For Research Use Only. Not for use in diagnostic procedures.
規格
For Use With (Equipment)3130xl Genetic Analyzer, 3730xl DNA Analyzer, 3730 DNA Analyzer, 3130 Genetic Analyzer
Format96-well Plate
Product TypeSepta Plate
Quantity20 each
Shipping ConditionRoom Temperature
Unit SizeEach
內容物與存放
Each package contains 20 septa, sufficient for 1,920 samples.

常見問答集 (常見問題)

Is the Plate Septa, 96 well (Cat. No. 4315933) compatible with 3500/3500xL Genetic Analyzers?

Yes, it is compatible with all versions of 3500/3500xL Genetic Analyzers as well as the 3500/3500xL Dx Genetic Analyzers, specifically in RUO mode.

How often can the plate septa on the 3130/xl, 3730/xl, 3500/xl, and SeqStudio instruments be used?

We officially recommend that the plate septa be used one time only. However, we are aware that some of our customers will rinse the septa with water and re-use them. In those instances, the septa can become sticky and gummy over time and eventually start sticking to the array. In the best case scenario, the array will lift the plate off of the autosampler just enough to break the connection with the plate sensor and abort the run. The Event Log might show that the run aborted due to the user aborting it, so the run will appear to have completed or stopped with no errors and no data. The worst case scenario is that the plate remains on the array as the autosampler starts to move, bending the electrodes and breaking the array. We recommend replacing the plate septa regularly (replacing after each run is recommended). Do not use bleach, detergents, or solvents to clean the septa, it will cause them to dry out faster and also risks contaminating the system.

Find additional tips, troubleshooting help, and resources within our Capillary Electrophoresis Software Support Center.