Pierce™ C18 Spin Tips & Columns
Pierce™ C18 Spin Tips & Columns
Pierce™ C18 Spin Tips & Columns
Pierce™ C18 Spin Tips & Columns
Thermo Scientific™

Pierce™ C18 Spin Tips & Columns

Thermo Scientific Pierce C18 Spin Columns (10–150 μL) and Spin Tips (10–100 μL) effectively remove interfering contaminants, while also maintaining excellent binding and recovery of peptide samples for use upstream of mass spectrometry and other high sensitivity detection methods.
Have Questions?
變更視圖buttonViewtableView
產品號碼QuantityProduct Type
8778496 x 100 μL TipsPipette Tip
8987025 ColumnsColumn
8987350 ColumnsColumn
8485096 TipsSpin Tip
8778296 x 10 μL TipsPipette Tip
產品號碼 87784
價格 (TWD)
14,400.00
線上優惠
Ends: 31-Dec-2025
18,000.00
您節省 3,600.00 (20%)
Each
新增至購物車
Quantity:
96 x 100 μL Tips
Product Type:
Pipette Tip
Request bulk or custom format
價格 (TWD)
14,400.00
線上優惠
Ends: 31-Dec-2025
18,000.00
您節省 3,600.00 (20%)
Each
新增至購物車
Matrix-assisted laser desorption ionization (MALDI) and electrospray ionization (ESI) mass spectrometry (MS) provide high sensitivity and mass accuracy; however, interfering molecules from the sample can result in reduced sensitivity and poor-quality spectra. Sample clean-up with C18 resins significantly improves signal-to-noise ratios and sequence coverage by removing MS-incompatible salts and detergents commonly used in protein or peptide preparation. The optimized protocol for the Pierce C-18 Spin Columns effectively removes contaminants and elutes peptides in MS-compatible solutions.

Pierce C18 Spin Columns
Thermo Scientific Pierce C18 Spin Columns are ready-to-use centrifuge columns of porous C18 reverse-phase resin for peptide sample preparation for MS and other analysis methods. The protocol has been optimized to efficiently remove interfering contaminants and release peptides in MS-compatible solutions. Columns can be used effectively for processing peptides derived from 10 ng to 30 μg of protein. Sensitivity and detection limits are dependent on the downstream application.

Efficient—effectively removes interfering contaminants to improve spectral quality and is suitable for a variety of reverse-phase-compatible contaminants
Flexible—works with a wide variety of load volumes and concentrations; no need to reduce sample volume before application
Convenient—spin column format requires no special equipment to process multiple samples simultaneously
Robust—special C18 resin allows excellent recovery percentages, even at low (sub-picomole) sample loads

Pierce C18 Spin Tips
Thermo Scientific Pierce C18 Spin Tips enable fast and efficient capture, concentration, desalting, and elution of up to 10 μg of peptides per 20 μL of sample with volumes ranging from 10 to 100 μL. The five-step procedure is simple and requires less than five minutes to process protein digests, strong cation exchange fractions, and other protein and peptide samples for mass spectrometric (MS) analyses. The Pierce C18 Spin Tips offer excellent flow properties with a high-efficiency monolithic C18 sorbent for fast wetting, loading, washing, and eluting.

Efficient—effectively removes interfering contaminants to improve spectral quality and is suitable for a variety of reverse-phase-compatible contaminants
Rapid—C18 fast-flow tips have low resistance and improved flow
Convenient—spin tips are provided with tip adaptor for easy centrifugation
Cleaner sample—device filters particulates that can cause autosampler and column clogging

Applications
• Clean-up of peptides after protein digestion
• Peptide sample concentration and desalting
• Sample preparation for MALDI peptide analysis and proteomics workflows

Matrix-assisted laser desorption ionization (MALDI) and electrospray ionization (ESI) mass spectrometry (MS) are essential for studying biological compounds because of the high sensitivity and mass accuracy they provide. However, many of the buffers and compounds common to biological samples interfere with both MALDI-MS and ESI-MS, resulting in reduced sensitivity and poor-quality spectra. Pierce C-18 Spin Columns remove interfering contaminants and release peptides in MS-compatible solutions, providing an effective tool that aids in the MS examination of post-translational modifications or for the identification of proteins by peptide mapping.

For Research Use Only. Not for use in diagnostic procedures.
規格
DescriptionPierce C-18 Tips, 100 μL bed
Final Product TypePeptides
For Use With (Equipment)Microcentrifuge, Mass Spectrometer
Quantity96 x 100 μL Tips
Workflow StepSample Clean Up
Detection MethodMass Spectrometry
FormatTip
Product LinePierce
Product TypePipette Tip
Starting MaterialPeptides, Protease-digested Protein
Unit SizeEach
內容物與存放
Store at room temperature.

引用資料與參考文獻 (3)

引用資料與參考文獻
Abstract
Carboxylate-Modified Magnetic Bead (CMMB)-Based Isopropanol Gradient Peptide Fractionation (CIF) Enables Rapid and Robust Off-Line Peptide Mixture Fractionation in Bottom-Up Proteomics.
Authors:Deng W,Sha J,Plath K,Wohlschlegel JA
Journal:Molecular & cellular proteomics : MCP
PubMed ID:33476790
Deep proteome coverage in bottom-up proteomics requires peptide-level fractionation to simplify the complex peptide mixture before analysis by tandem mass spectrometry. By decreasing the number of coeluting precursor peptide ions, fractionation effectively reduces the complexity of the sample leading to higher sample coverage and reduced bias toward high-abundance precursors that ... More
Anti-inflammatory therapeutic biomarkers identified of human bone marrow mesenchymal stem cell therapy on aging mice by serum proteomics and peptidomics study.
Authors:Niu H,Wang BY,Wei XY,Wang YN,Zhu WH,Li WJ,Zhang Y,Wang JC
Journal:Journal of proteomics
PubMed ID:37524227
Aging is accompanied by deterioration in physical condition, and creates high risks of diseases. Stem cell therapy exhibited promising potential in delaying aging. However, the unelucidated therapeutic mechanism limits future clinical application. Herein, to systematically understand the response to stem cell transfusion at the molecular level, we performed quantitative serum ... More
An optimized co-immunoprecipitation protocol for the analysis of endogenous protein-protein interactions in cell lines using mass spectrometry.
Authors:Lagundžin D,Krieger KL,Law HC,Woods NT
Journal:STAR protocols
PubMed ID:35300004
This protocol represents an optimized proteomics-based protocol for the endogenous protein enrichment and protein-protein interaction analysis. This 2-step protocol consists of: 1) co-immunoprecipitation of the bait protein; 2) the bait-protein interactions analysis using LC-MS/MS. Here, we used Dynabeads® for the enrichment of the target protein (the bait) and its interactors. ... More