Thermo Scientific™

Pierce™ High Capacity Ni-IMAC Resin, EDTA compatible

產品號碼: A50584
Thermo Scientific™

Pierce™ High Capacity Ni-IMAC Resin, EDTA compatible

產品號碼: A50584
產品號碼
A50584
包裝規格
10 mL
價格 (TWD)
價格 7,140.00
線上優惠 4,998.00
(01-Jul-2024 結束)
您的價格
供應狀況
***
數量
產品號碼
包裝規格
50 mL
價格 (TWD)
價格 29,100.00
線上優惠 20,370.00
(01-Jul-2024 結束)
您的價格
供應狀況
***
數量
產品號碼
包裝規格
250 mL
價格 (TWD)
價格 124,500.00
線上優惠 87,150.00
(01-Jul-2024 結束)
您的價格
供應狀況
***
數量
產品號碼
包裝規格
500 mL
價格 (TWD)
價格 222,600.00
線上優惠 178,080.00
您的價格
供應狀況
***
數量
產品號碼包裝規格價格 (TWD)供應狀況數量
A5058410 mL
價格 7,140.00
線上優惠 4,998.00
(01-Jul-2024 結束)
您的價格
***
A5058550 mL
價格 29,100.00
線上優惠 20,370.00
(01-Jul-2024 結束)
您的價格
***
A50586250 mL
價格 124,500.00
線上優惠 87,150.00
(01-Jul-2024 結束)
您的價格
***
A50587500 mL
價格 222,600.00
線上優惠 178,080.00
您的價格
***
產品概覽
圖表
影片
建議
建議
文件
常見問題
引用資料與參考文獻
其他資訊
建議
Pierce high-capacity EDTA-compatible Ni-IMAC resin is designed for the purification of over-expressed His-tagged proteins from cell culture media. The matrix is a 6% crosslinked agarose with optimal properties for batch, gravity column, and research/pilot scale FPLC column purifications. The resin has high binding capacity (up to 80 mg of protein per mL of resin) and can tolerate the high EDTA and reducing agent concentrations used to inhibit metalloproteases and stabilize sensitive intracellular proteins.

Features of the high-capacity EDTA-compatible Ni-IMAC resin include:
• Chelator stable—use up to 20 mM EDTA and DTT with no loss in performance
• Compatible with purification of overexpressed, secreted proteins in cell culture media (e.g., Expi293, ExpiCHO, and ExpiSf expression systems)
• High binding capacity—>80 mg/mL binding capacity for His-tagged recombinant proteins
• Reusable—can be regenerated up to 10 times using the CIP protocol

EDTA and reducing agents such as DTT and TCEP adversely affect the performance of Ni-IMAC supports by stripping off the metal. Because of its chelator stability characteristic (EDTA tolerant), Pierce high-capacity EDTA-compatible Ni-IMAC resin is especially suited for purifying expressed His-tagged proteins that are secreted into cell culture media or for purifying intracellular His-tagged proteins that need the presence of EDTA to maintain stability and function. In both cases, large quantities of samples can be purified without the Ni metal stripping off of the support, thereby providing consistent high capacity yields.
For Research Use Only. Not for use in diagnostic procedures.

規格

Capacity (Metric)
80 mg per mL Binding
Binding Property
Chelator Stable
Description
EDTA compatible Ni-IMAC resin for His-tag protein purification
Matrix
6% crosslinked agarose
Shipping Condition
Wet Ice
Particle Size
50 to 80 μm
Form
Liquid Suspension
Product Line
Pierce™
Quantity
10 mL
Type
Resin
Column Type
Bottle

內容物與存放

10 mL settled resin, supplied as 20 mL 50% slurry. Store at 2–8°C.

圖表

文件與下載

證書

    常見問答集 (常見問題)

    引用資料與參考文獻

    Search citations by name, author, journal title or abstract text