Thermo Scientific™

Orbitrap Eclipse™ Tribrid™ Mass Spectrometer

產品號碼: FSN04-10000
Thermo Scientific™

Orbitrap Eclipse™ Tribrid™ Mass Spectrometer

產品號碼: FSN04-10000

Obtain high confidence insights for very complex molecules with the Thermo Scientific™ Orbitrap Eclipse™ Tribrid™ mass spectrometer. It combines industry-leading versatility and usability with the exceptional performance afforded by its built-in intelligence and revolutionary Thermo Scientific™ Tribrid™ architecture to deliver an instrument designed to address the most difficult analytical challenges. This newest Tribrid platform includes Advanced Ion Management Technology (AIM+) with the new QR5 segmented quadrupole mass filter, Real-Time Search, Enhanced Vacuum Technology, optional Proton Transfer Charge Reduction (PTCR), and optional High Mass Range MSn (HMRn) mode. Collectively, these features make this instrument uniquely suited for accurate and high-throughput full-proteome quantitation, characterization of complex mixtures of protein or small molecule-based pharmaceuticals, and deciphering higher-order protein structures. The Orbitrap Eclipse Tribrid MS makes it easy to tackle these difficult analyses and collect the high-quality data required to drive the right decisions, pushing your science beyond today's discovery.

 
產品號碼
FSN04-10000
Unit Size
Each
Description
Orbitrap Eclipse Tribrid MS
價格 (TWD)
完整規格
TypeOrbitrap LC-MS
Dynamic Range>5000 with a single OTMS spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyOrbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
Scan RatesOTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
Polarity SwitchingOne Full Cycle in < 1.1 sec
DescriptionOrbitrap Eclipse Tribrid MS
Dimensions (D x W x H)30 x 50 x 28 in. (77 x 127 x 70 cm)
Weight (Metric)180 kg (400 lb.)
Max. ResolutionUp to 500,000 at m/z 200
Unit SizeEach
產品號碼
Unit Size
Each
Description
Orbitrap Eclipse Tribrid MS - Internal Calibration Ready (Easy IC)
價格 (TWD)
完整規格
TypeOrbitrap LC-MS
Dynamic Range>5000 with a single OTMS spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyOrbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
Resolution7500 to 500,000 (FWHM) at m/z 200
Scan RatesOTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
Polarity SwitchingOne Full Cycle in < 1.1 sec
DescriptionOrbitrap Eclipse Tribrid MS - Internal Calibration Ready (Easy IC)
Dimensions (D x W x H)30 x 50 x 28 in. (77 x 127 x 70 cm)
Weight (Metric)180 kg (400 lb.)
Unit SizeEach
產品號碼
Unit Size
Each
Description
Orbitrap Eclipse Tribrid MS - Electron Transfer Dissociation Ready (Easy-ETD)
價格 (TWD)
完整規格
TypeOrbitrap LC-MS
Dynamic Range>5000 with a single OTMS spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyOrbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
Resolution7500 to 500,000 (FWHM) at m/z 200
Scan RatesOTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
Polarity SwitchingOne Full Cycle in < 1.1 sec
DescriptionOrbitrap Eclipse Tribrid MS - Electron Transfer Dissociation Ready (Easy-ETD)
Dimensions (D x W x H)30 x 50 x 28 in. (77 x 127 x 70 cm)
Weight (Metric)180 kg (400 lb.)
Unit SizeEach
產品號碼
Unit Size
Each
Description
Orbitrap Eclipse Tribrid MS - Proton Transfer Charge Reduction Ready (PTCR)
價格 (TWD)
完整規格
TypeOrbitrap LC-MS
Dynamic Range>5000 with a single OTMS spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyOrbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
Resolution7500 to 500,000 (FWHM) at m/z 200
Scan RatesOTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
Polarity SwitchingOne Full Cycle in < 1.1 sec
DescriptionOrbitrap Eclipse Tribrid MS - Proton Transfer Charge Reduction Ready (PTCR)
Dimensions (D x W x H)30 x 50 x 28 in. (77 x 127 x 70 cm)
Weight (Metric)180 kg (400 lb.)
Unit SizeEach
產品號碼
Unit Size
Each
Description
Orbitrap Eclipse Tribrid MS Upgrade to Easy-IC
價格 (TWD)
完整規格
TypeOrbitrap LC-MS
Dynamic Range>5000 within one spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyInternal: <1 ppm RMS
External: <3 ppm RMS
Resolution500,000 at m/z 200
Scan RatesMSn for n = 1 through 10
Polarity SwitchingOne Full Cycle in <1.1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000))
SensitivityMS/MS: 100 fg Reserpine on Column S/N 200:1; test requires HESI II probe.
DescriptionOrbitrap Eclipse Tribrid MS Upgrade to Easy-IC
Weight (Metric)180 kg (400 lb.) without data system, vacuum rough pumps and optional items
Unit SizeEach
產品號碼
Unit Size
Each
Description
Orbitrap Eclipse Tribrid MS equipped with Easy-ETD Upgrade to PTCR
價格 (TWD)
完整規格
TypeOrbitrap LC-MS
Dynamic Range>5000 within one spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyInternal: <1 ppm RMS
External: <3 ppm RMS
Resolution500,000 at m/z 200
Scan RatesMSn for n = 1 through 10
Polarity SwitchingOne Full Cycle in <1.1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000))
SensitivityMS/MS: 100 fg Reserpine on Column S/N 200:1; test requires HESI II probe.
DescriptionOrbitrap Eclipse Tribrid MS equipped with Easy-ETD Upgrade to PTCR
Weight (Metric)180 kg (400 lb.) without data system, vacuum rough pumps and optional items
Unit SizeEach
顯示 6 項,共 6 項
產品號碼規格Unit SizeDescription價格 (TWD)
FSN04-10000完整規格
EachOrbitrap Eclipse Tribrid MS申請報價
TypeOrbitrap LC-MS
Dynamic Range>5000 with a single OTMS spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyOrbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
Scan RatesOTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
Polarity SwitchingOne Full Cycle in < 1.1 sec
DescriptionOrbitrap Eclipse Tribrid MS
Dimensions (D x W x H)30 x 50 x 28 in. (77 x 127 x 70 cm)
Weight (Metric)180 kg (400 lb.)
Max. ResolutionUp to 500,000 at m/z 200
Unit SizeEach
FSN04-10001完整規格
EachOrbitrap Eclipse Tribrid MS - Internal Calibration Ready (Easy IC)申請報價
TypeOrbitrap LC-MS
Dynamic Range>5000 with a single OTMS spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyOrbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
Resolution7500 to 500,000 (FWHM) at m/z 200
Scan RatesOTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
Polarity SwitchingOne Full Cycle in < 1.1 sec
DescriptionOrbitrap Eclipse Tribrid MS - Internal Calibration Ready (Easy IC)
Dimensions (D x W x H)30 x 50 x 28 in. (77 x 127 x 70 cm)
Weight (Metric)180 kg (400 lb.)
Unit SizeEach
FSN04-10002完整規格
EachOrbitrap Eclipse Tribrid MS - Electron Transfer Dissociation Ready (Easy-ETD)申請報價
TypeOrbitrap LC-MS
Dynamic Range>5000 with a single OTMS spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyOrbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
Resolution7500 to 500,000 (FWHM) at m/z 200
Scan RatesOTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
Polarity SwitchingOne Full Cycle in < 1.1 sec
DescriptionOrbitrap Eclipse Tribrid MS - Electron Transfer Dissociation Ready (Easy-ETD)
Dimensions (D x W x H)30 x 50 x 28 in. (77 x 127 x 70 cm)
Weight (Metric)180 kg (400 lb.)
Unit SizeEach
FSN04-10003完整規格
EachOrbitrap Eclipse Tribrid MS - Proton Transfer Charge Reduction Ready (PTCR)申請報價
TypeOrbitrap LC-MS
Dynamic Range>5000 with a single OTMS spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyOrbitrap mass accuracy:
<3 ppm RMS using external calibration
<1 ppm RMS using internal calibration
Resolution7500 to 500,000 (FWHM) at m/z 200
Scan RatesOTMSn: Up to 40 Hz
ITMSn: Up to 45 Hz
Polarity SwitchingOne Full Cycle in < 1.1 sec
DescriptionOrbitrap Eclipse Tribrid MS - Proton Transfer Charge Reduction Ready (PTCR)
Dimensions (D x W x H)30 x 50 x 28 in. (77 x 127 x 70 cm)
Weight (Metric)180 kg (400 lb.)
Unit SizeEach
FETD3-10001完整規格
EachOrbitrap Eclipse Tribrid MS Upgrade to Easy-IC申請報價
TypeOrbitrap LC-MS
Dynamic Range>5000 within one spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyInternal: <1 ppm RMS
External: <3 ppm RMS
Resolution500,000 at m/z 200
Scan RatesMSn for n = 1 through 10
Polarity SwitchingOne Full Cycle in <1.1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000))
SensitivityMS/MS: 100 fg Reserpine on Column S/N 200:1; test requires HESI II probe.
DescriptionOrbitrap Eclipse Tribrid MS Upgrade to Easy-IC
Weight (Metric)180 kg (400 lb.) without data system, vacuum rough pumps and optional items
Unit SizeEach
FETD3-10003完整規格
EachOrbitrap Eclipse Tribrid MS equipped with Easy-ETD Upgrade to PTCR申請報價
TypeOrbitrap LC-MS
Dynamic Range>5000 within one spectrum
Mass RangeStandard mass range: 50 to 2000 m/z
Mid mass range: 200 to 6000 m/z
Optemonal HMRn mass range: 500 to 8000 m/z
Mass AccuracyInternal: <1 ppm RMS
External: <3 ppm RMS
Resolution500,000 at m/z 200
Scan RatesMSn for n = 1 through 10
Polarity SwitchingOne Full Cycle in <1.1 Sec (One Full Positive Mode Scan and One Full Negative Mode Scan (at a Resolution Setting of 30,000))
SensitivityMS/MS: 100 fg Reserpine on Column S/N 200:1; test requires HESI II probe.
DescriptionOrbitrap Eclipse Tribrid MS equipped with Easy-ETD Upgrade to PTCR
Weight (Metric)180 kg (400 lb.) without data system, vacuum rough pumps and optional items
Unit SizeEach
顯示 6 項,共 6 項

With its built-in intelligence and versatility, the Orbitrap Eclipse Tribrid MS makes it easy to produce the high quality data required to drive the right decisions.

  • Exceptional precursor selectivity and sensitivity with the next generation quadrupole mass filter
  • Unmatched depth and accuracy of TMT analysis with novel Real-Time Search
  • High Mass Range MSn (HMRn) option for comprehensive analysis of native protein complexes
  • Unique Proton Transfer Charge Reduction (PTCR) option for simplifying complex top-down spectra
  • Full experimental flexibility with revolutionary instrument control
  • A wide range of optional functionalities for unprecedented versatility
  • Common user interface with Thermo Scientific™ Orbitrap Exploris™ 480 and TSQ™ triple quadrupole mass spectrometers

圖表

文件與下載

證書

    常見問答集 (常見問題)

    引用資料與參考文獻

    Search citations by name, author, journal title or abstract text