Achieve ultimate helium isotope analysis with the Thermo Scientific™ Helix SFT™ split flight tube noble gas mass spectrometer. This compact but powerful magnetic sector static vacuum mass spectrometer (SVMS) is capable of the high-precision analysis all noble gas isotopes, but is ideally suited to the simultaneous collection of the isotopes helium 3 and helium 4.

 
產品號碼
IQLAAEGACVFAKUMAWM
Unit Size
Each
Mass Range
1 to 150 Da
Sensitivity
Helium: > 2 x 10-4amps/Torr at 800μA trap current, Argon: > 1 x 10-3amps/Torr at 200μA trap current
Rate of Rise
Rate of Rise at Mass 40 to be Less Than 1 x 10-12cc STP/Min of Argon 40
價格 (TWD)
完整規格
TypeNoble Gas MS
Mass Range1 to 150 Da
BackgroundEqual or Better Than 5 e-14cc STP (at Mass 36)
Peak Side StabilityDrift to be less than the equivalent of ±25ppm in mass over 30 minutes at mass 40
Rate of RiseRate of Rise at Mass 40 to be Less Than 1 x 10-12cc STP/Min of Argon 40
SensitivityHelium: > 2 x 10-4amps/Torr at 800μA trap current, Argon: > 1 x 10-3amps/Torr at 200μA trap current
Unit SizeEach
顯示 1 項,共 1 項
產品號碼規格Unit SizeMass RangeSensitivityRate of Rise價格 (TWD)
IQLAAEGACVFAKUMAWM完整規格
Each1 to 150 DaHelium: > 2 x 10-4amps/Torr at 800μA trap current, Argon: > 1 x 10-3amps/Torr at 200μA trap currentRate of Rise at Mass 40 to be Less Than 1 x 10-12cc STP/Min of Argon 40申請報價
TypeNoble Gas MS
Mass Range1 to 150 Da
BackgroundEqual or Better Than 5 e-14cc STP (at Mass 36)
Peak Side StabilityDrift to be less than the equivalent of ±25ppm in mass over 30 minutes at mass 40
Rate of RiseRate of Rise at Mass 40 to be Less Than 1 x 10-12cc STP/Min of Argon 40
SensitivityHelium: > 2 x 10-4amps/Torr at 800μA trap current, Argon: > 1 x 10-3amps/Torr at 200μA trap current
Unit SizeEach
顯示 1 項,共 1 項
Innovations That Make a Total Helium Solution
  • Simultaneous analysis of helium isotopes, without peak jumping, reduces analysis time and improves throughput
  • Nier-type ion source provides excellent sensitivity while maintaining a low trap / total emission ratio for long filament life and low source temperatures
  • Extremely low internal volume enhances sensitivity
  • Low-mass collector includes a 50 mm 90 degree energy filter that enables the system to measure extremely large ratios without peak tailing—abundance sensitivity is <1 ppb (3 contribution from 4)
  • Excellent low-mass resolution completely separates helium 3 from HD and H3+ interferences
  • Innovative amplifier technology enables the majority of analyses to be done with long-life Faraday detectors

Specifications, terms, and pricing are subject to change. Not all products are available in all countries. Please consult your local sales representative for details.