Shop All Capillaries & Polymers
3130/3100-Avant Genetic Analyzer 4-Capillary Array, 22 cm (Applied Biosystems™)
This is a 22 cm 4-capillary array (internally uncoated) for the 3130 and 3100 Avant™ Genetic Analyzer. Use for short fragment analysis. Capillary dimensions are 33 cm x 50 µm i.d. Usage per array is 100 runs.
3130/3100-Avant Genetic Analyzer 4-Capillary Array, 36 cm (Applied Biosystems™)
This is a 36 cm 4-capillary array (internally uncoated) for the 3130 and 3100 Avant™ Genetic Analyzer. Use for sequencing and fragment analysis. Capillary dimensions are 47 cm x 50 µm i.d. Usage per array is 100 runs (with use of Applied Biosystems reagents).
3130/3100-Avant Genetic Analyzer 4-Capillary Array, 80 cm (Applied Biosystems™)
This is an 80 cm 4-capillary array (internally uncoated) for the 3130 and 3100 Avant™ Genetic Analyzer. Use for long read sequencing. Capillary dimensions are 91 cm x 50 µm i.d. Usage per array is 100 runs.
POP-6™ Polymer for the 310 Genetic Analyzer (Applied Biosystems™)
POP-6™ is a denaturing polymer used on the 310 Genetic Analyzer. POP-6™ Polymer is used for sequencing applications.
• Easy to Use: Pre-formulated, which not only saves time but also saves reproducibility by ensuring consistent formulation.
• Robust Formulation: Formulated for sequencing and fragment analysis applications.
• Replenishable: Allow capillaries to be used multiple times.
Reproducible Results
POP™ polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP Polymers are specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.
Used With
1.0 mL Glass Syringe, 310 Genetic Analyzer Capillary, 47 cm (36 cm wtr), 310 Genetic Analyzer Capillary, 61 cm (50 cm wtr), 310 Running Buffer, 10X , BigDye® Terminator v1.1 Cycle Sequencing Kit, BigDye® Terminator v3.1 Cycle Sequencing Kit, Genetic Analyzer Sample Tubes, 0.5 ml, Hi-Di™ Formamide, POP-4® Polymer for the 310 Genetic Analyzer, Septa for 0.5 ml Sample Tubes.
Note: For Research Use Only. Not for use in diagnostics procedures.
• Easy to Use: Pre-formulated, which not only saves time but also saves reproducibility by ensuring consistent formulation.
• Robust Formulation: Formulated for sequencing and fragment analysis applications.
• Replenishable: Allow capillaries to be used multiple times.
Reproducible Results
POP™ polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP Polymers are specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.
Used With
1.0 mL Glass Syringe, 310 Genetic Analyzer Capillary, 47 cm (36 cm wtr), 310 Genetic Analyzer Capillary, 61 cm (50 cm wtr), 310 Running Buffer, 10X , BigDye® Terminator v1.1 Cycle Sequencing Kit, BigDye® Terminator v3.1 Cycle Sequencing Kit, Genetic Analyzer Sample Tubes, 0.5 ml, Hi-Di™ Formamide, POP-4® Polymer for the 310 Genetic Analyzer, Septa for 0.5 ml Sample Tubes.
Note: For Research Use Only. Not for use in diagnostics procedures.
POP™ Conformational Analysis Polymer (CAP) (Applied Biosystems™)
This POP™ polymer is a Conformational Analysis Polymer for non-denaturing polynucleotide fragment analysis applications on Genetic Analyzers.
For Research Use Only. Not for use in diagnostics procedures.
For Research Use Only. Not for use in diagnostics procedures.
POP-6™ Polymer for 3130/3130xl Genetic Analyzers (Applied Biosystems™)
The POP-6™ Polymer is a separation matrix for performing standard and rapid DNA sequencing on the Applied Biosystems 3130 and the Applied Biosystems 3130xl Genetic Analyzers. Usage per bottle: Up to 960 samples.
POP-6™ Polymer is a separation matrix for the 3130⁄3130xl Genetic Analyzers that is:
• Easy to Use: Pre-formulated, which not only saves time but also saves reproducibility by ensuring consistent formulation.
• Robust Formulation: Formulated for sequencing and fragment analysis applications.
• Replenishable: Allow capillaries to be used multiple times.
Reproducible Results
POP-6™ polymer dynamically coats the capillary wall to control electro-osmotic flow. Its definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP-4® Polymer is specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time. For the ABI PRISM® 310 and 3100 Genetic Analyzers POP-6™ polymers are the choice for standard and rapid sequencing. For the ABI PRISM® 3700 DNA Analyzer, POP-6™ polymer is designed for genotyping applications.
Used With
3130 Genetic Analyzer, Hi-Di™ Formamide.
For Research Use Only. Not for use in diagnostics procedures.
POP-6™ Polymer is a separation matrix for the 3130⁄3130xl Genetic Analyzers that is:
• Easy to Use: Pre-formulated, which not only saves time but also saves reproducibility by ensuring consistent formulation.
• Robust Formulation: Formulated for sequencing and fragment analysis applications.
• Replenishable: Allow capillaries to be used multiple times.
Reproducible Results
POP-6™ polymer dynamically coats the capillary wall to control electro-osmotic flow. Its definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP-4® Polymer is specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time. For the ABI PRISM® 310 and 3100 Genetic Analyzers POP-6™ polymers are the choice for standard and rapid sequencing. For the ABI PRISM® 3700 DNA Analyzer, POP-6™ polymer is designed for genotyping applications.
Used With
3130 Genetic Analyzer, Hi-Di™ Formamide.
For Research Use Only. Not for use in diagnostics procedures.
POP-7™ Polymer for Protein Quality Analysis (Applied Biosystems™)
This is a pouch of POP-7 polymer for protein quality analysis on 3500/3500xL genetic analyzers. The POP-7 separation matrix is validated for protein quality analysis and is offered in easy-to-use pouch packages and 960 sample (maximum) or 384 sample (maximum) size formats.
• Easy to use—pre-formulated and in a single-use pouch, which not only saves time but ensures reliability and consistency
• Includes radio frequency identification (RFID) label—easily track important information such as part/lot number, samples remaining, and expiry dates (displayed on software dashboard)
• Robust formulation—formulated for biomolecular analysis applications
• Replenishable—allows capillaries to be used multiple times
Reproducible results
POP polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help ensure reproducibility. POP polymers are specifically formulated to separate biomolecules of known size range at a desired resolution and run time.
For partially-used pouches that need to be stored, a cap that plugs into the pouch opening is recommended (Cat. No. 4412619).
• Easy to use—pre-formulated and in a single-use pouch, which not only saves time but ensures reliability and consistency
• Includes radio frequency identification (RFID) label—easily track important information such as part/lot number, samples remaining, and expiry dates (displayed on software dashboard)
• Robust formulation—formulated for biomolecular analysis applications
• Replenishable—allows capillaries to be used multiple times
Reproducible results
POP polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help ensure reproducibility. POP polymers are specifically formulated to separate biomolecules of known size range at a desired resolution and run time.
For partially-used pouches that need to be stored, a cap that plugs into the pouch opening is recommended (Cat. No. 4412619).
POP-4™ Polymer for 3100/3100-Avant; Genetic Analyzers (Applied Biosystems™)
POP-4® is a DNA sequencing and fragment analysis reagent and consumable. It is a separation matrix for performing fragment analysis and sequencing on the 3100 Genetic Analyzer and 3100-Avant™ Genetic Analyzer. The POP-4® Polymer is ideally suited for denaturing fragment analysis applications such as microsatellite and SNP genotyping Analysis.
Many Choices
For the ABI PRISM® 310 and 3100 Genetic Analyzers, POP-4® polymers are designed for microsatellite and other genotyping applications, while POP-6™ polymers are the choice for standard and rapid sequencing. For the ABI PRISM® 3700 DNA Analyzer, POP-5™ polymer is the separation matrix of choice for high-throughput DNA sequencing, while POP-6™ polymer is designed for genotyping applications.
New Bottle Material
Our POP4™ and polymer POP6™ polymer bottles for use on the 3100 will now be comprised of the same material used for polymer bottles for the 3130. The new bottles will resemble the current bottles in shape, color, form, and function. We have conducted extensive internal testing using the new bottles, and are confident that the new material will consistently provide the highest quality product. If you would like more information please contact customer resources.
For Research Use Only. Not for use in diagnostics procedures.
Many Choices
For the ABI PRISM® 310 and 3100 Genetic Analyzers, POP-4® polymers are designed for microsatellite and other genotyping applications, while POP-6™ polymers are the choice for standard and rapid sequencing. For the ABI PRISM® 3700 DNA Analyzer, POP-5™ polymer is the separation matrix of choice for high-throughput DNA sequencing, while POP-6™ polymer is designed for genotyping applications.
New Bottle Material
Our POP4™ and polymer POP6™ polymer bottles for use on the 3100 will now be comprised of the same material used for polymer bottles for the 3130. The new bottles will resemble the current bottles in shape, color, form, and function. We have conducted extensive internal testing using the new bottles, and are confident that the new material will consistently provide the highest quality product. If you would like more information please contact customer resources.
For Research Use Only. Not for use in diagnostics procedures.
3130xl/3100 Genetic Analyzer 16-Capillary Array, 50cm (Applied Biosystems™)
This is a 50 cm 16-capillary array (internally uncoated) for the 3130xl and 3100 Genetic Analyzer. Use for fragment analysis and sequencing applications. Capillary dimensions are 61 cm x 50 µm i.d. Usage per array is 100 runs (with use of Applied Biosystems reagents).
SeqStudio™ Cartridge (Applied Biosystems™)
The Applied Biosystems SeqStudio Cartridge is an all-in-one and easy-to-use reagent cartridge that includes capillaries, universal polymer, buffer, and pump required to run on the SeqStudio Genetic Analyzer System. The universal polymer allows for flexibility to perform Sanger sequencing and fragment analysis on the same instrument run with the same cartridge. Just load your samples, click in the cartridge, and go.
Key features:
• Minimize hands-on setup time with all-in-one cartridge
• Track consumables usage through radio frequency identification (RFID)
• Extended on-instrument 4-month shelf life for cartridge after opening
• Allows for 125 injections or 500 reactions per cartridge
Key features:
• Minimize hands-on setup time with all-in-one cartridge
• Track consumables usage through radio frequency identification (RFID)
• Extended on-instrument 4-month shelf life for cartridge after opening
• Allows for 125 injections or 500 reactions per cartridge
3130/3100-Avant Genetic Analyzer 4-Capillary Array, 50 cm (Applied Biosystems™)
This is a 50 cm 4-capillary array (internally uncoated) for the 3130 and 3100 Avant™ Genetic Analyzer. Use for fragment analysis and sequencing. Capillary dimensions are 61 cm x 50 µm i.d. Usage per array is 100 runs (with use of Applied Biosystems reagents).
POP-4™ Polymer for the 310 Genetic Analyzer (Applied Biosystems™)
POP-4® is a denaturing polymer used for the 310 Genetic Analyzer. POP-4® Polymer Each is customized for denaturing fragment analysis applications such as microsatellite and SNP genotyping analysis.
• Easy to Use: Pre-formulated, which not only saves time but also saves reproducibility by ensuring consistent formulation.
• Robust Formulation: Formulated for sequencing and fragment analysis applications.
• Polymers allow capillaries to be used multiple times.
Reproducible Results
POP™ polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP Polymers are specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.
Used With:
1.0 mL Glass Syringe, 310 Genetic Analyzer Capillary, 47 cm (36 cm wtr), 310 Genetic Analyzer Capillary, 61 cm (50 cm wtr), 310 Running Buffer, 10X , AmpFLSTR® Yfiler® PCR Amplification Kit, AmpFLSTR® Identifiler® PCR Amplification Kit, AmpFLSTR® SGM Plus® PCR Amplification Kit, AmpliTaq Gold® DNA Polymerase, 1, 000 units with Buffer II and MgCl2 solution, BigDye® Terminator v1.1 Cycle Sequencing Kit, GeneScan™ 400HD ROX™ Size Standard, GeneScan™ 500 LIZ™ Size Standard, GeneScan™ 500 ROX™ Size Standard, Genetic Analyzer Sample Tubes, 0.5 ml, Hi-Di™ Formamide, MicroAmp® 8-Tube Strip, 0.2 ml, MicroAmp® Reaction Tube with Cap, 0.2 ml, POP-4® Polymer for 3130⁄3130xl Genetic Analyzers, POP-6™ Polymer for the 310 Genetic Analyzer, Quantifiler® Human DNA Quantification Kit, Septa for 0.5 ml Sample Tubes.
Note: For Research Use Only. Not for use in diagnostics procedures.
• Easy to Use: Pre-formulated, which not only saves time but also saves reproducibility by ensuring consistent formulation.
• Robust Formulation: Formulated for sequencing and fragment analysis applications.
• Polymers allow capillaries to be used multiple times.
Reproducible Results
POP™ polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP Polymers are specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.
Used With:
1.0 mL Glass Syringe, 310 Genetic Analyzer Capillary, 47 cm (36 cm wtr), 310 Genetic Analyzer Capillary, 61 cm (50 cm wtr), 310 Running Buffer, 10X , AmpFLSTR® Yfiler® PCR Amplification Kit, AmpFLSTR® Identifiler® PCR Amplification Kit, AmpFLSTR® SGM Plus® PCR Amplification Kit, AmpliTaq Gold® DNA Polymerase, 1, 000 units with Buffer II and MgCl2 solution, BigDye® Terminator v1.1 Cycle Sequencing Kit, GeneScan™ 400HD ROX™ Size Standard, GeneScan™ 500 LIZ™ Size Standard, GeneScan™ 500 ROX™ Size Standard, Genetic Analyzer Sample Tubes, 0.5 ml, Hi-Di™ Formamide, MicroAmp® 8-Tube Strip, 0.2 ml, MicroAmp® Reaction Tube with Cap, 0.2 ml, POP-4® Polymer for 3130⁄3130xl Genetic Analyzers, POP-6™ Polymer for the 310 Genetic Analyzer, Quantifiler® Human DNA Quantification Kit, Septa for 0.5 ml Sample Tubes.
Note: For Research Use Only. Not for use in diagnostics procedures.
310 Genetic Analyzer Capillary, 61 cm (50 cm wtr - well to read) (Applied Biosystems™)
This is an internally uncoated Capillary for the 310 Genetic Analyzer, 61 cm x 50 µm. Use for sequencing applications. 100 runs per capillary.
Used With:
1.0 mL Glass Syringe, 310 Running Buffer, 10X, POP-4® Polymer for the 310 Genetic Analyzer, POP-6™ Polymer for the 310 Genetic Analyzer.
For Research Use Only. Not for use in diagnostics procedures.
Used With:
1.0 mL Glass Syringe, 310 Running Buffer, 10X, POP-4® Polymer for the 310 Genetic Analyzer, POP-6™ Polymer for the 310 Genetic Analyzer.
For Research Use Only. Not for use in diagnostics procedures.
POP-7™ Polymer for 3500 Dx/3500xL Dx Genetic Analyzers (Applied Biosystems™)
3500 Dx Series POP-7™ and POP-6™ are separation matrices for the 3500 Dx⁄3500xL Dx Genetic Analyzers. They are conveniently offered in easy-to-use pouch packages with either 960 samples (maximum) or 384 samples (maximum) size formats. Each polymer is optimized for specific applications.
Easy to Use
Polymer is pre-formulated in a single use pouch, which not only saves time but also ensures reliability and consistency.
Radio Frequency Identification (RFID) label
The RFID encodes easy-to-track important information such as part⁄lot number, samples remaining and expiry dates (displayed on software dashboard)
Robust Formulation
Polymers are formulated for a wide range of applications.
Reproducible Results
POP™ polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP Polymers are specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.
Many Choices
POP-7™ polymer is very versatile and designed for a wide range of short-read to long-read sequencing applications. POP-6™ polymer is the choice for certain sequencing applications.
Performance Optimized Polymer
This product is intended for in-vitro diagnostic use on the Applied Biosystems 3500 Dx Series Genetic Analyzers and is not validated for use with other systems or applications. The 3500 Dx Series Genetic Analyzer is to be used by trained operators in the analysis of human DNA or RNA, for the detection of genetic changes that may lead to disease presence or susceptibility. Off-label uses such as fragment analysis are for research use only. Refer to the Applied Biosystems 3500 Dx⁄3500xL Dx Genetic Analyzer User Guide for further details.
Easy to Use
Polymer is pre-formulated in a single use pouch, which not only saves time but also ensures reliability and consistency.
Radio Frequency Identification (RFID) label
The RFID encodes easy-to-track important information such as part⁄lot number, samples remaining and expiry dates (displayed on software dashboard)
Robust Formulation
Polymers are formulated for a wide range of applications.
Reproducible Results
POP™ polymers dynamically coat the capillary wall to control electro-osmotic flow. Their definite quality and uniform consistency eliminate guesswork and help to ensure reproducibility. POP Polymers are specifically formulated to separate DNA fragments of a known size range at a desired resolution and run time.
Many Choices
POP-7™ polymer is very versatile and designed for a wide range of short-read to long-read sequencing applications. POP-6™ polymer is the choice for certain sequencing applications.
Performance Optimized Polymer
This product is intended for in-vitro diagnostic use on the Applied Biosystems 3500 Dx Series Genetic Analyzers and is not validated for use with other systems or applications. The 3500 Dx Series Genetic Analyzer is to be used by trained operators in the analysis of human DNA or RNA, for the detection of genetic changes that may lead to disease presence or susceptibility. Off-label uses such as fragment analysis are for research use only. Refer to the Applied Biosystems 3500 Dx⁄3500xL Dx Genetic Analyzer User Guide for further details.
POP-7™ Polymer for 3130/3130xl Genetic Analyzers (Applied Biosystems™)
Le polymère POP-7™ est une matrice de séparation permettant d’effectuer le séquençage d’ADN et l’analyse des fragments sur les analyseurs génétiques Applied Biosystems 3130 et Applied Biosystems 3130xl. Usage par flacon : Jusqu’à 960 échantillons.
Le polymère POP-7™ est une matrice de séparation pour les analyseurs génétiques 3130⁄3130xl :
• Facile à utiliser : Préformulé, ce qui permet non seulement de gagner du temps mais aussi de stimuler la reproductibilité en assurant une formulation uniforme.
• Formulation fiable : Formulé pour les applications de séquençage et d’analyse des fragments.
• Réapprovisionnable : Permet une utilisation multiple des capillaires.
Résultats reproductibles
Le polymère POP-7™ forme un revêtement dynamique au niveau de la paroi capillaire pour contrôler le flux électro-osmotique. Son excellente qualité et son uniformité permettent de lever les hypothèses et d’assurer la reproductibilité. Le polymère POP-7™ est spécifiquement formulé pour séparer les fragments d’ADN d’une certaine taille à une résolution souhaitée et pendant une durée spécifique.
Pour l’analyseur d’ADN ABI PRISM® 3700, le polymère POP-7™ est la matrice de séparation idéale pour le séquençage d’ADN à haut débit.
Utilisé avec
le tampon de charge 310, 10X, l’analyseur génétique 3130, le réseau capillaire de l’analyseur génétique 3130⁄3100-Avant™, 22 cm, le réseau capillaire de l’analyseur génétique 3130⁄3100-Avant™, 36 cm, le réseau capillaire de l’analyseur génétique 3130⁄3100-Avant™, 50 cm, le réseau capillaire de l’analyseur génétique 3130⁄3100-Avant™, 80 cm, le réseau capillaire de l’analyseur génétique 3130xl⁄3100, 22 cm, le réseau capillaire de l’analyseur génétique 3130xl⁄3100, 36 cm, le réseau capillaire de l’analyseur génétique 3130xl⁄3100, 50 cm, le réseau capillaire de l’analyseur génétique 3130xl⁄3100, 80 cm, le septum de plaques de 96 puits, le kit de séquençage de cycles BigDye® Terminator v1.1, le kit de séquençage de cycles BigDye® Terminator v3.1, le kit de séquençage de cycles BigDye® Terminator v3.1, la norme de dimension GeneScan™ 500 LIZ™, la norme de dimension GeneScan™ 500 ROX™, le formamide Hi-Di™, la plaque de réaction optique de 96 puits MicroAmp®, le kit de conversion du bisulfite methylSEQr™.
Remarque : Usage exclusivement réservé à la recherche. Ne pas utiliser pour des procédures de diagnostic.
Le polymère POP-7™ est une matrice de séparation pour les analyseurs génétiques 3130⁄3130xl :
• Facile à utiliser : Préformulé, ce qui permet non seulement de gagner du temps mais aussi de stimuler la reproductibilité en assurant une formulation uniforme.
• Formulation fiable : Formulé pour les applications de séquençage et d’analyse des fragments.
• Réapprovisionnable : Permet une utilisation multiple des capillaires.
Résultats reproductibles
Le polymère POP-7™ forme un revêtement dynamique au niveau de la paroi capillaire pour contrôler le flux électro-osmotique. Son excellente qualité et son uniformité permettent de lever les hypothèses et d’assurer la reproductibilité. Le polymère POP-7™ est spécifiquement formulé pour séparer les fragments d’ADN d’une certaine taille à une résolution souhaitée et pendant une durée spécifique.
Pour l’analyseur d’ADN ABI PRISM® 3700, le polymère POP-7™ est la matrice de séparation idéale pour le séquençage d’ADN à haut débit.
Utilisé avec
le tampon de charge 310, 10X, l’analyseur génétique 3130, le réseau capillaire de l’analyseur génétique 3130⁄3100-Avant™, 22 cm, le réseau capillaire de l’analyseur génétique 3130⁄3100-Avant™, 36 cm, le réseau capillaire de l’analyseur génétique 3130⁄3100-Avant™, 50 cm, le réseau capillaire de l’analyseur génétique 3130⁄3100-Avant™, 80 cm, le réseau capillaire de l’analyseur génétique 3130xl⁄3100, 22 cm, le réseau capillaire de l’analyseur génétique 3130xl⁄3100, 36 cm, le réseau capillaire de l’analyseur génétique 3130xl⁄3100, 50 cm, le réseau capillaire de l’analyseur génétique 3130xl⁄3100, 80 cm, le septum de plaques de 96 puits, le kit de séquençage de cycles BigDye® Terminator v1.1, le kit de séquençage de cycles BigDye® Terminator v3.1, le kit de séquençage de cycles BigDye® Terminator v3.1, la norme de dimension GeneScan™ 500 LIZ™, la norme de dimension GeneScan™ 500 ROX™, le formamide Hi-Di™, la plaque de réaction optique de 96 puits MicroAmp®, le kit de conversion du bisulfite methylSEQr™.
Remarque : Usage exclusivement réservé à la recherche. Ne pas utiliser pour des procédures de diagnostic.
