7300 Real Time PCR Systems Spectral Calibration Kit (Applied Biosystems™)

This easy-to-use kit establishes the pure dye spectra and multicomponent values for FAM™/SYBR® Green I, VIC®/JOE™, and NED™/TAMRA™/ROX™ dyes on the Applied Biosystems® 7300 Real-Time PCR System. The Applied Biosystems® 7300 Real-Time PCR Systems Spectral Calibration Kit I contains one background plate, one region of interest (ROI) calibration plate, and seven spectral calibration plates with seven separate dye standards.

• 96-well optical reaction plates preloaded with dyes (FAM™/SYBR® Green I, VIC®/JOE™, NED™/TAMRA™/ROX™) enable you to calibrate the 7300 Real-Time PCR System quickly and easily
• Easy-to-use, preloaded spectral calibration plates reduce setup time
• Provides accurate discrimination of the fluorescence signal of individual dyes in the reaction mixture
• Includes the Passive Reference I dye standard for signal normalization in all real-time and endpoint reactions

Spend Your Time on Research, Not Instrument Calibration
This kit is easy-to-use, preloaded, 96-well optical reaction plates enable quick and easy calibration of the 7300 Real-Time PCR System. Insert the reaction plates during system installation, and the system automatically collects the dye standard's spectral information. The system's application algorithm then uses this calibration information to ensure accurate data analysis.

Sequence Detection Systems Spectral Calibration Kit, 96-well (Applied Biosystems™)

This Applied Biosystems® easy-to-use kit establishes the pure dye spectra and multicomponent values for FAM™, JOE™, NED™,ROX™, SYBR® Green, TAMRA™, TET™, and VIC™ dyes on the standard 96-well block of the ABI PRISM® 7900HT Sequence Detection System. The Sequence Detection Systems Spectral 96-Well Calibration kit includes three optical 96-well reaction plates: one preloaded and sealed background plate, and two preloaded and sealed spectral calibration plates with eight separate dye standards.
• 96-well optical reaction plates preloaded with dyes (FAM™, JOE™, NED™,ROX™, SYBR® Green , TAMRA™, TET™, and VIC™) are provided for quick and easy calibration of the standard 96-well block of the ABI PRISM® 7900HT Sequence Detection System
• Easy-to-use and provides accurate discrimination of the fluorescence signal of individual dyes in the reaction mixture
• Includes the Passive Reference I dye standard for signal normalization in all real-time and endpoint reactions Spend Your Time on Research—Not Instrument Calibration This kit's easy-to-use, preloaded, 96-well optical reaction plates enable users to calibrate the standard 96-well block of the ABI PRISM® 7900HT Sequence Detection System quickly and easily. Insert the reaction plates during system installation, and the system automatically collects the dye standard's spectral information. The system's application algorithm then uses the calibration information to ensure accurate data analysis.

7900HT TaqMan™ Low Density Array Instrument Verification RNase P Kit (Applied Biosystems™)

The 7900HT TaqMan® Low Density Array Instrument Verification RNase P kit is used to validate the performance of the Applied Biosystems® 7900HT Fast Real-Time PCR Systems with the TaqMan® Low Density Array Block Upgrade. The 7900HT TaqMan® Low Density Array Instrument Verification RNase P kit contains an empty TaqMan® Low Density Array and 8 vials of RNase P detection reagents to detect and quantitate genomic copies of the human RNase P gene, a single-copy gene encoding the RNA moiety of the RNase P enzyme. Each vial contains premixed reagents (1X TaqMan® Universal PCR Master Mix, RNase P primers, and FAM™ dye–labeled probe) and template. The 7900HT TaqMan® Low Density Array Instrument Verification RNase P kit must demonstrate the ability to distinguish between 5,000 and 10,000 genomic equivalents with a 99.7% confidence level for a subsequent sample run in a single well. To ensure accurate results, Applied Biosystems® recommends that the performance of your instrument be verified every six months.

JUN™ Dye Spectral Calibration Plate for Multiplex qPCR, Fast 96-well (Applied Biosystems™)

This plate is used for JUN® dye spectral calibration of your 7500 Fast, ViiA™ 7, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, and QuantStudio™ 12K Flex real-time PCR systems with a Fast 96-well block. Calibration and verification should be run at least every six months. Please see your instrument maintenance guide for full instructions on use. The dye formulations will improve results with multiplexing by more accurately representing fluorescent spectra found in your real-time PCR experiments.

QuantStudio™ 3/5 Spectral Calibration Plate 3 (TAMRA™, NED™, Cy™5 dyes), 96-well, 0.2 mL (Applied Biosystems™)

This plate establishes the pure dye spectra and multicomponent values for TAMRA™, NED™, and Cy®5 dyes on Applied Biosystems™ QuantStudio™ 3 and 5 96-well 0.2-mL real-time PCR systems. It enables simultaneous multiple dye calibrations in one plate, significantly reducing effort and time required for dye calibration. Please refer to the instrument user guide for full instructions on usage.

QuantStudio™ 3/5 Spectral Calibration Plate 3 (TAMRA™, NED™, Cy™5 dyes), 96-well, 0.1 mL (Applied Biosystems™)

This plate establishes the pure dye spectra and multicomponent values for TAMRA™, NED™, and Cy®5 dyes on Applied Biosystems™ QuantStudio™ 3 and 5 96-well 0.1-mL real-time PCR systems. It enables simultaneous multiple dye calibrations in one plate, significantly reducing effort and time required for dye calibration. Please refer to the instrument user guide for full instructions on usage.

7500 Fast Real-Time PCR Systems Spectral Calibration Kit I (Applied Biosystems™)

This easy-to-use kit enables you to establish the pure dye spectra and multicomponent values for FAM™⁄SYBR® Green I, VIC®⁄JOE™, and NED™⁄TAMRA™⁄ROX™ dyes on the 7500 Fast Real-Time PCR System.

The Applied Biosystems® 7500 Real-Time PCR Systems Spectral Calibration Kit I contains nine Optical 96-Well Fast Thermocycling Plates: one preloaded and sealed background plate, seven preloaded and sealed plates with seven separate dye standards, and one region-of-interest (ROI) plate.

• 96-well optical reaction plates preloaded with dyes (FAM™⁄SYBR® Green I, VIC®⁄JOE™, NED™⁄TAMRA™⁄ROX™) allow quick and easy calibration of the 7500 Fast Real-Time PCR System
• Easy-to-use, preloaded spectral calibration kit allows accurate discrimination of the individual dyes in a reaction mixture when all the dyes are excited simultaneously
• Includes the Passive Reference I dye standard required for signal normalization in all real-time and endpoint reactions

Spend Your Time on Research — Not Instrument Calibration

This kit's easy-to-use, preloaded 96-well optical reaction plates enable quick and easy calibration of the 7500 Fast Real-Time PCR System. Insert the reaction plates during system installation, and the system collects the dye standard's spectral information. The system's application algorithm then uses the calibration information to ensure accurate data analysis.

FAM™ Dye Spectral Calibration Plate, 384-well (Applied Biosystems™)

This kit is used for FAM™ spectral calibration of your ViiA™ 7, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, or QuantStudio™ 12K Flex system with a 384-well block. Please see your instrument maintenance guide for full instructions on use.

These calibration kits are used to maintain your real-time PCR system with 384-Well Block. They include calibration plates to perform a spectral calibration with FAM™, VIC®, ROX™, SYBR® Green, TAMRA™, NED™ dyes, plates to perform region-of-interest (ROI) calibration, normalization calibration, and to run an RNase P verification. Calibration and verification should be run at least every six months. Please see your instrument maintenance guide for full instructions on use.

The dye formulations for your ViiA™ 7, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, or QuantStudio™ 12K Flex system will improve results with multiplexing by more accurately representing fluorescent spectra found in your real-time PCR experiments.

MUSTANG PURPLE™ Dye Spectral Calibration Plate, 96-well (Applied Biosystems™)

This plate is used for MUSTANG PURPLE® spectral calibration of your Applied Biosystems® 7500, ViiA™ 7, QuantStudio™ 6, QuantStudio™ 7, or QuantStudio™ 12K Flex real-time PCR system with a 96-well block. Please see your instrument maintenance guide for full instructions on use. The dye formulations will help improve multiplexing results by more accurately representing fluorescent spectra that are part of your real-time PCR experiments.

TaqMan™ Low Density Array Spectral Calibration Kit (Applied Biosystems™)

The TaqMan® Low Density Array Spectral Calibration Kit is used to validate the performance of the Applied Biosystems® 7900HT Fast Real-Time PCR Systems with the TaqMan® Low Density Array Block Upgrade. The TaqMan® Low Density Array Spectral Calibration Kit contains four empty TaqMan® Low Density Array, one background tube, and three separate pure dye standards (FAM™, ROX™,VIC®). Insert the loaded calibration arrays during system installation, and the system collects the dye standard's spectral information. The system's application algorithm then uses the calibration information to ensure accurate data analysis. To ensure accurate results, we recommend that the performance of your instrument be verified every six months.

Normalization Kit, Fast 96-well (Applied Biosystems™)

The Fast 96-Well Normalization Kit is used to maintain your real-time PCR instrument with Fast 96-well block. Normalization plates are used to calibrate different instruments. The kit contains one FAM™/ROX™ normalization plate and one VIC®/ROX™ normalization plate. Please see your instrument user guide for full instructions on use.

ABY™ Dye Spectral Calibration Plate for Multiplex qPCR, 384-well (Applied Biosystems™)

This plate is used for ABY® dye spectral calibration of your ViiA™ 7, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, and QuantStudio™ 12K Flex real-time PCR systems with a 384-well block. Calibration and verification should be run at least every six months. Please see your instrument maintenance guide for full instructions on use. The dye formulations will improve results with multiplexing by more accurately representing fluorescent spectra found in your real-time PCR experiments.

TaqMan™ RNase P Instrument Verification Plate, Fast 96-well (for 0.1 mL block) (Applied Biosystems™)

The TaqMan® RNase P Fast 96-Well Instrument Verification Plate is used to verify the performance of the Applied Biosystems® 7500 Fast, Applied Biosystems® 7900 HT Fast, StepOnePlus™, ViiA™ 7, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, or QuantStudio™ 12K Flex real-time PCR system equipped with a 96-well block. The TaqMan® RNase P Fast 96-Well Instrument Verification Plate is a sealed Optical 96-Well Fast Thermal Cycling Plate preloaded with necessary reagents to detect and quantitate genomic copies of the human RNase P gene, a single-copy gene encoding the RNA moiety of the RNase P enzyme. Each well contains preloaded reaction mix (1X TaqMan® Universal PCR Master Mix, RNase P primers, and FAM™ dye–labeled probe) and template.

The TaqMan® RNase P Fast 96-Well Instrument Verification Plate satisfies the same requirements as the real-time PCR system installation. To pass installation, the instruments must demonstrate the ability to distinguish between 5,000 and 10,000 genomic equivalents with a 99.7% confidence level for a subsequent sample run in a single well. To ensure accurate results, we recommend that the performance of your instrument be verified every six months.

TaqMan™ RNase P Instrument Verification Plate for 7900HT System, 384-well (Applied Biosystems™)

The Applied Biosystems® TaqMan® RNase P 384-Well Instrument Verification Plate is used to verify the performance of the Applied Biosystems® 7900HT Fast Real-Time PCR System. The TaqMan® RNase P 384-Well Instrument Verification Plate is a 384-well PCR plate preloaded with the necessary reagents to detect and quantitate genomic copies of the human RNase P gene, a single-copy gene encoding the RNA moiety of the RNase P enzyme. Each well contains preloaded reaction mix (1X TaqMan® Universal PCR Master Mix, RNase P primers, and FAM™ dye–labeled probe) and template.
The TaqMan® RNase P Instrument 384-Well Instrument Verification Plate satisfies the same requirements as the Applied Biosystems® 7900 HT Real-Time PCR Systems installation. To pass installation, the instruments must demonstrate the ability to distinguish between 5,000 and 10,000 genomic equivalents with a 99.7% confidence level for a subsequent sample run in a single well. To ensure accurate results, Applied Biosystems® recommends that the performance of your instrument be verified every six months.

MUSTANG PURPLE™ Dye Spectral Calibration Plate for Multiplex qPCR, 384-well (Applied Biosystems™)

This plate is used for MUSTANG PURPLE® dye spectral calibration of your ViiA™ 7, QuantStudio™ 6 Flex, QuantStudio™ 7 Flex, and QuantStudio™ 12K Flex real-time PCR systems with a 384-well block. Calibration and verification should be run at least every six months. Please see your instrument maintenance guide for full instructions on use. The dye formulations will improve results with multiplexing by more accurately representing fluorescent spectra found in your real-time PCR experiments.